HomeWork eventsremove and replace existing system with new 3 ton Ruud 14.3 seer2 with 7 kw heat

remove and replace existing system with new 3 ton Ruud 14.3 seer2 with 7 kw heat

Hvac event dated 2023-09-14.

Work event

Work event PKevent_d7abd4549adc62427137
Work typeResidential Mechanical
Work categoryHvac
Descriptionremove and replace existing system with new 3 ton Ruud 14.3 seer2 with 7 kw heat
Work date2023-09-14
Status-
Source record ID20230963983
JurisdictionCharlotte County Accela Building jurisdiction

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_d7abd4549adc62427137
Firm IDfirm_3db7b081e4fb3f097eeb
Local Identity IDidentity_46c17dbf9d46f4de8475
Portal Keycharlotte_accela
Jurisdiction ScopeCharlotte County Accela Building jurisdiction
Source Record ID20230963983
Work Event ID20230963983
Work TypeResidential Mechanical
Work Categoryhvac
Descriptionremove and replace existing system with new 3 ton Ruud 14.3 seer2 with 7 kw heat
Observed Project Value-
Value Typeunknown
Value SourceCharlotte Accela Accela public detail value
Value Confidence-
Work Date2023-09-14
Status-
Site Address27205 JONES LOOP RD, 46, Punta Gorda FL 33982 United States
City-
StateFL
Postal Code-
CountyCharlotte
Parcel ID412323303015
Latitude-
Longitude-
Source URLhttps://aca-prod.accela.com/BOCC/Cap/CapDetail.aspx?Module=Building&TabName=Building&ca...
Raw Payload Pathartifacts/business-backfills/charlotte_accela/run_date=2026-06-05/09-14-2023_09-14-2023_type-all_pages-50_details-all.json
Imported At2026-06-05
Source Fields
{
  "business_display_name": "JAMES E SHIPMAN",
  "city": null,
  "confidence_notes": "Live Accela date-window import; value and contractor parsed from public CapDetail page.",
  "county": "Charlotte",
  "description": "remove and replace existing system with new 3 ton Ruud 14.3 seer2 with 7 kw heat",
  "email": null,
  "insurance_or_bond_summary": null,
  "jurisdiction_scope": "Charlotte County Accela Building jurisdiction",
  "legal_or_dba_name": "JAMES E SHIPMAN",
  "license_number": "CAC1820315",
  "license_status": null,
  "license_type": "PUNTA GORDA, FL, 33955 | C HARV CLASS A  CAC1820315",
  "mailing_or_firm_address": "WOLVERINE AIR INC",
  "parcel_id": "412323303015",
  "phone": "9418157185",
  "portal_key": "charlotte_accela",
  "postal_code": null,
  "qualifier_name": "35864",
  "raw_payload_path": "artifacts/business-backfills/charlotte_accela/run_date=2026-06-05/09-14-2023_09-14-2023_type-all_pages-50_details-all.json",
  "scope_layer": "county_permitting_authority",
  "site_address": "27205 JONES LOOP RD, 46, Punta Gorda FL 33982 United States",
  "source_fields": {
    "detail": {
      "detail_text_sample": "Accela Citizen Access\nLogin\nRegister for an Account\n|\nAnnouncements\n(\n)\n|\nMark as Read\nmore\nmore\nMessage Bar\nPermit\n20230963983\n:\nResidential Mechanical\nRecord Status:\nClosed\nCreate a New Collection\n*\nName:\nDescription:\nAdd\nCancel\nRecord Info\nPermit Details\nReview Status\nRelated Permits\nAttachments\nInspections\nValuation Calculator\nPayments\nFees\nTrust Account Information\nConditions\nMore...\nCustom Component\nView your\nPlan Review\ncomments by clicking the \"Record Info\" menu above then select \"Review Status\".\nIMPORTANT:\nView and print your\nJOB CARD\nby clicking the \"Print/View Job Card\" button at the bottom of the screen.\nNote:  You\nmust be logged in to the permitting site\nto print or view your Job Card.\nJob Site Location:\n27205 JONES LOOP RD\n46\nPunta Gorda FL 33982\nADDRESSKEY: 257886\nADDID: 331815\nHISTORICAL: HISTORICAL\n*\nPermit Details\nApplicant:\nJAMES\nE\nSHIPMAN\nWOLVERINE AIR INC\n27066 NOTRE DAME BLVD\nPUNTA GORDA,\nFL,\n33955\nHome Phone:\n9418157185\nMobile Phone:\n9418157185\[email protected]\nLicensed Professional:\nJAMES E SHIPMAN\nWOLVERINE AIR INC\n35864\n27066 NOTRE DAME BLVD\nPUNTA GORDA, FL, 33955\nHome Phone:\n9418157185\nMobile Phone:\n9418157185\nC HARV CLASS A  CAC1820315\nJob Description:\nremove and replace existing system with new 3 ton Ruud 14.3 seer2 with 7 kw heat\nOwner:\nVENTURA LAKES MHC-NM LLC\n*\n12629 NEW BRITTANY BLVD\nFORT MYERS FL 33907\nMore Details\nRelated Contacts\nOwner information\nE\nFORT MYERS, FL, 33907\nOwner information\nE\nFORT MYERS, FL, 33907\nApplication Information\nGENERAL\nInspection Notification Options:\nReceive EMAIL and TEXT\nExpiration Date - This field will be filled automatically when your application is submitted. It will be updated periodically as you permit moves through the process:\n03/05/2025\nConstruction Cost - If this exceeds $2500 ($15000 for HVAC), a Notice of Commencement MUST be on file with the Building Department prior to your first inspection.:\n5500\nStorm Name:\nNot Applicable\nREQUIRED HVAC INFORMATION\nWhat type of work are you doing?:\nReplacement\nWill electrical work be part of this job?:\nNo\nWhat is the extent of the work?:\nComplete System\nIf this is a replacement, please list the size of the unit being replaced.:\n3\nAre you making any changes to the ductwork?:\nNo\nIs this a package unit?:\nYes\nWhat is the SEER?:\n14.3\nWhat is the KW?:\n7\nHow many tons is the unit?:\n3\nParcel Information\nParcel Number:412323303015\n*\nBlock:0000\nLot:0000\nSubdivision:ZZZ\nBLDG_TOTAL_AREA: 6302\nDOC_EXEMPT: N\nLAND_USE: Improved Commercial\nASSESSED_VALUE: 2669274\nPARCEL_ACRES: 19.63\nTAX_DISTRICT: 104\nACLF: N\nTURTLEZONE: OUT\nFZONE: AE,X\nSFHA: OUT\nFLOODWAY: OUT\nIDNUM_BIT: 47\nL1_SUBDIVISION: ZZZ\nISLAND: undefined\nFees\nLoading...\nInspections\nThe inspections specific to your job are listed below under \"Upcoming Inspections\" with a status of \"Pending.\" To schedule an inspection listed as \"Pending,\" click the \"Action\" button next to the inspection and select \"Schedule.\"\nPlease review this section carefully to ensure that all required inspections are scheduled and completed as needed throughout the duration of the project.\nTo schedule CCU and Health Department inspections, please reach out to the corresponding office directly.\nCharlotte County Utilities (CCU) Inspections\nCall 941-764-4300 option 3 (water/sewer), for these inspection types:\nCCU Gravity Sewer\nCCU LPS Connection\nCCU Meter Installation\nCCU Vacuum Sewer\nCall 941-764-4589 for:\nCCU Backflow Preventor\nCall 941-764-4387 for:\nCCU Interceptor\nFlorida Department of Health Inspections\nTo schedule a Health Approval Inspection, please call 941-624-7200.\nLoading...\nUpcoming Inspections\nYou have not added any inspections.\nCompleted\nThere are no completed inspections on this record.\nAttachments\n***ATTACHMENT INSTRUCTIONS***\nImportant:  If attaching either of these document types, please upload\nafter\npermit payment.\nAFFIDAVIT FOR NO ZONING INSPECTION\n: If you are submitting an Affidavit for No Zoning Inspection, your PDF document\nmust\nbe named\nWaiveZoning\n(case sensitive) for correc",
      "job_value": "",
      "licensed_professional": {
        "city_state_zip": "27066 NOTRE DAME BLVD",
        "company": "JAMES E SHIPMAN",
        "license_holder": "35864",
        "license_notes": "PUNTA GORDA, FL, 33955 | C HARV CLASS A  CAC1820315",
        "phones": {
          "home_phone": "9418157185",
          "mobile_phone": "9418157185"
        },
        "street_address": "WOLVERINE AIR INC"
      },
      "licensed_professional_raw": "JAMES E SHIPMAN | WOLVERINE AIR INC | 35864 | 27066 NOTRE DAME BLVD | PUNTA GORDA, FL, 33955 | Home Phone: 9418157185 | Mobile Phone: 9418157185 | C HARV CLASS A  CAC1820315",
      "owner": "VENTURA LAKES MHC-NM LLC",
      "pcn": "412323303015",
      "value_label": ""
    },
    "grid_cells": [
      "",
      "09/14/2023",
      "20230963983",
      "Residential Mechanical",
      "remove and replace existing system with new 3 ton Ruud 14.3 seer2 with 7 kw heat",
      "Closed",
      "27205 JONES LOOP RD, 46, Punta Gorda FL 33982 United States",
      "",
      "27205 JONES LOOP RD, 46, Punta Gorda FL 33982 United States"
    ],
    "grid_inferred": {
      "application_date": "09/14/2023",
      "description": "remove and replace existing system with new 3 ton Ruud 14.3 seer2 with 7 kw heat",
      "record_type": "Residential Mechanical",
      "site_address": "27205 JONES LOOP RD, 46, Punta Gorda FL 33982 United States",
      "status": null
    },
    "work_category": "hvac"
  },
  "source_record_id": "20230963983",
  "source_url": "https://aca-prod.accela.com/BOCC/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=23MEC&capID2=00000&capID3=04182&agencyCode=BOCC&IsToShowInspection=",
  "state": "FL",
  "status": null,
  "work_date": "2023-09-14",
  "work_event_id": "20230963983",
  "work_type": "Residential Mechanical",
  "work_value": null,
  "work_value_source": "Charlotte Accela Accela public detail value"
}
Get this page with API

Rendered from the bluedoor Licensed Contractors API. Reproduce it:

GET https://api.bluedoor.sh/licensed-contractors/v1/work-events/event_d7abd4549adc62427137?include_source_fields=trueJSON
remove and replace existing system with new 3 ton Ruud 14.3 seer2 w... — Licensed Contractors data | bluedoor