Source Fields
{
"business_display_name": "KR2 CONSTRUCTION LLC",
"city": null,
"confidence_notes": "Live Accela date-window import; value and contractor parsed from public CapDetail page.",
"county": "Pinellas",
"description": "- Remove & replace existing front entry door system.- Remodel existing M.bath and closet/suite to allow elevator access to that floor level.- install a NFW emergency stand-by generator....B/E/P/M/G...NOC REQ ON JOB SITE **REVISION: During the scheduled inspection of the gas piping, the inspector noted that the placement of the generator, while originally approved, is actually placed closer than five feet from two different wall openings. Current codes require that there be at least five feet between any part of the generator unit and an openings in the home's exterior wall. Because of this, the inspection was failed until the situation can be satisfactory resolved. The permit scope amendment seeks permission to resolve this situation by eliminating the existing service door to the garage, and be reducing the overall size of an existing flood vent while still providing adequate code required flood vent areas.**",
"email": "[email protected]",
"insurance_or_bond_summary": null,
"jurisdiction_scope": "Pinellas County Accela Building jurisdiction",
"legal_or_dba_name": "KR2 CONSTRUCTION LLC",
"license_number": null,
"license_status": null,
"license_type": null,
"mailing_or_firm_address": "3198 E Martana Drive",
"parcel_id": "302915076860001160",
"phone": null,
"portal_key": "pinellas_accela",
"postal_code": null,
"qualifier_name": "St Pete Beach, FL, 33706",
"raw_payload_path": "artifacts/business-backfills/pinellas_accela/run_date=2026-06-03/07-13-2023_07-13-2023_type-all_pages-50_details-all.json",
"scope_layer": "county_permitting_authority",
"site_address": "2701 BAYSHORE DR, BELLEAIR BEACH 33786",
"source_fields": {
"detail": {
"detail_text_sample": "Accela Citizen Access\nLogin\n|\nRegister for an Account\n|\nAnnouncements\n(\n)\n|\nMark as Read\nmore\nmore\nMessage Bar\nRecord\nBR-RMR-23-00735\n:\nResidential Remodel/Repair/Renovation\nRecord Status:\nClosed - Finaled\nExpiration Date:\n11/12/2024\nCreate a New Collection\n*\nName:\nDescription:\nspell check\nAdd\nCancel\nRecord Info\nRecord Details\nProcessing Status\nAttachments\nInspections\nPayments\nFees\nConditions\nWork Location\n2701 BAYSHORE DR\nBELLEAIR BEACH 33786\n*\nRecord Details\nReplacing a\nwater heater, AC unit\nor\nwater softener\n? Virtual inspections are now available for these permit types.\nLearn more\n.\nVirtual inspections will be available for more permit types soon.\nLicensed Professional:\nKelly Rae Essary [email protected]\nKR2 CONSTRUCTION LLC\n3198 E Martana Drive\nSt Pete Beach, FL, 33706\nGeneral Contractor CGC1524761\nView Additional Licensed Professionals>>\n1)\nDavid Leon Griffith [email protected]\nDAVID GRIFFITH CONSTRUCTION INC\nP.O Box 49293\nSt. Petersburg, FL, 33710\nPhone:\n727580-6827\nMobile Phone:\n727580-6827\nPlumbing Contractor CFC1430673\n2)\nDavid Leon Griffith [email protected]\nPROFESSIONAL AIR SOLUTIONS INC\n5980 66th St N Ste B\nSt Petersburg, FL, 33709\nPhone:\n727822-6600\nMobile Phone:\n727580-6827\nAir Cond A Contractor CAC1817440\n3)\nRaymond F Sieper [email protected]\nON TIME ELECTRIC INC\n16204 Turnbury Oak Drive\nOdessa, FL, 33556\nPhone:\n813545-9333\nMobile Phone:\n813545-9333\nElectrical Contractor EC13009205\nProject Description:\nRS - INT. REMODEL W/ELEVATOR AND GENERATOR - SMITH - 7/17/2023\n- Remove & replace existing front entry door system.- Remodel existing M.bath and closet/suite to allow elevator access to that floor level.- install a NFW emergency stand-by generator....B/E/P/M/G...NOC REQ ON JOB SITE **REVISION: During the scheduled inspection of the gas piping, the inspector noted that the placement of the generator, while originally approved, is actually placed closer than five feet from two different wall openings. Current codes require that there be at least five feet between any part of the generator unit and an openings in the home's exterior wall. Because of this, the inspection was failed until the situation can be satisfactory resolved. The permit scope amendment seeks permission to resolve this situation by eliminating the existing service door to the garage, and be reducing the overall size of an existing flood vent while still providing adequate code required flood vent areas.**\nOwner:\nSMITH, LAURA K TRE\n*\n7647 FOREST HILL RD\nBURR RIDGE RD IL 60527-5101\nMore Details\nRelated Contacts\nContractor information\nKelly\nRae\nEssary\nKR2 CONSTRUCTION LLC\n3198 E Martana Drive\nSt Pete Beach, FL, 33706\nHome Phone:\n727424-9893\nMobile Phone:\n727424-9893\nE-mail:\[email protected]\nContractor information\nKelly\nR\nEssary\nKR2 Construction LLC\nHome Phone:\n7274249893\nMobile Phone:\n7276435131\nE-mail:\[email protected]\nBusiness\n2830 46th ave N\nSt Petersburg, FL, 33714\nApplication Information\nGENERAL INFO\nPermit Subtype:\nInterior Remodel\nNumber of Dwelling Units:\n1\nIs this an owner/builder Permit?:\nNo\nBUILDING COM/RES INFO\nValue of Construction:\n99675\nWork Area:\n200\nPrivate Provider Review:\nNo\nIs there an Associated Site Plan?:\nNo\nTotal Area Under Roof:\n7608\nTotal Conditioned Area:\n3956\nBUILDING ZONING INFO\nFront Comment:\nno change per BB letter\nLeft Comment:\nno change per BB letter\nRear Comment:\nno change per BB letter\nRight Comment:\nno change per BB letter\nHELENE 2024\nIs this application due to damage from Hurricane Milton?:\nNo\nParcel Information\nParcel Number:302915076860001160\n*\nBlock:000\nLot:1160\nSubdivision:07686\nAIRPORT: N\nEVACZONE: A\nFIRE DISTRICT: Pinellas Suncoast\nFLOOD ZONE: AE\nGOVERNMENT OWNED: N\nHALF SECTION: 30S\nHISTORIC: N\nHOMESTEAD: N\nJURISDICTION: Belleair Beach\nSIZEACRES: 0.2020 a\nUNINCORPORATED: N\nWELLHEAD: N\nCODEAREA: CodeArea4\nCODEENFORCEAREAS: North\nBLDGINSPAREAS: B6\nELECINSPAREAS: E3\nMECHINSPAREAS: M3\nPLMNINSPAREAS: P1\nPROTECTEDPARCEL: No\nMODIFYDATE: 10/20/201",
"job_value": "99675",
"licensed_professional": {
"city_state_zip": "General Contractor CGC1524761",
"company": "KR2 CONSTRUCTION LLC",
"email": "[email protected]",
"license_holder": "St Pete Beach, FL, 33706",
"street_address": "3198 E Martana Drive"
},
"licensed_professional_raw": "Kelly Rae Essary [email protected] | KR2 CONSTRUCTION LLC | 3198 E Martana Drive | St Pete Beach, FL, 33706 | General Contractor CGC1524761",
"owner": "SMITH, LAURA K TRE",
"pcn": "302915076860001160",
"value_label": "Value of Construction"
},
"grid_cells": [
"",
"07/13/2023",
"Residential Remodel/Repair/Renovation",
"BR-RMR-23-00735",
"Closed - Finaled",
"",
"2701 BAYSHORE DR, BELLEAIR BEACH 33786",
"RS - INT. REMODEL W/ELEVATOR AND GENERATOR - SMITH - 7/17/2023",
"11/12/2024",
"- Remove & replace existing front entry door system.- Remodel existing M.bath and closet/suite to allow elevator access to that floor level.- install a NFW emergency stand-by generator....B/E/P/M/G...NOC REQ ON JOB SITE **REVISION: During the scheduled inspection of the gas piping, the inspector noted that the placement of the generator, while originally approved, is actually placed closer than five feet from two different wall openings. Current codes require that there be at least five feet between any part of the generator unit and an openings in the home's exterior wall. Because of this, the inspection was failed until the situation can be satisfactory resolved. The permit scope amendment seeks permission to resolve this situation by eliminating the existing service door to the garage, and be reducing the overall size of an existing flood vent while still providing adequate code required flood vent areas.**",
"2701 BAYSHORE DR, BELLEAIR BEACH 33786"
],
"grid_inferred": {
"application_date": "07/13/2023",
"description": "- Remove & replace existing front entry door system.- Remodel existing M.bath and closet/suite to allow elevator access to that floor level.- install a NFW emergency stand-by generator....B/E/P/M/G...NOC REQ ON JOB SITE **REVISION: During the scheduled inspection of the gas piping, the inspector noted that the placement of the generator, while originally approved, is actually placed closer than five feet from two different wall openings. Current codes require that there be at least five feet between any part of the generator unit and an openings in the home's exterior wall. Because of this, the inspection was failed until the situation can be satisfactory resolved. The permit scope amendment seeks permission to resolve this situation by eliminating the existing service door to the garage, and be reducing the overall size of an existing flood vent while still providing adequate code required flood vent areas.**",
"record_type": "Residential Remodel/Repair/Renovation",
"site_address": "2701 BAYSHORE DR, BELLEAIR BEACH 33786",
"status": "Closed - Finaled"
},
"work_category": "windows_doors"
},
"source_record_id": "BR-RMR-23-00735",
"source_url": "https://aca-prod.accela.com/PINELLAS/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=23CAP&capID2=00000&capID3=00QD2&agencyCode=PINELLAS&IsToShowInspection=",
"state": "FL",
"status": "Closed - Finaled",
"work_date": "2023-07-13",
"work_event_id": "BR-RMR-23-00735",
"work_type": "Residential Remodel/Repair/Renovation",
"work_value": 99675,
"work_value_source": "Pinellas Accela Value of Construction"
}