bluedoor data·Licensed Contractors API·bluedoor.sh ↗

HomeWork eventsTear-off existing shingle roofing to bare plywood deck, roofer to despose of debris. Re...

Tear-off existing shingle roofing to bare plywood deck, roofer to despose of debris. Re...

Roofing event dated 2023-11-14.

Work event

Work event PKevent_d6d71fafa900109ef1d0
Work typeResidential Roofing
Work categoryRoofing
DescriptionTear-off existing shingle roofing to bare plywood deck, roofer to despose of debris. Replace rotten plywood, structural lumber, and fascia boards as necessary.*** Re-nail existing plywood deck 6" o.c. with 8d ring shank nails per building code. Furnish and Install Apoc SB-1 self adhered underlayment direct to plywood deck. Furnish and Install GAF Seal-A-Ridge hip and ridge caps. Furnish and Install GAF Strip at all eaves. Furnish and Install all necesssary flashings for a complete roofing system. Furnish and Install 26 gauge drip edge with standard paint finish at all eaves and rakes. Furnish and Install 26 gauge valley metal at all valleys. Furnish and Install GAF Rigid Vent 3 ridge ventilation where currently existing. Furnish and Install lead pipe boots at all sewer stacks. Furnish and Install 26 gauge gooseneck vents at all dryer and kitchen vent locations. Paint all lead pipe boots, dryer vents, and kitchen vents to match shingle color. Reuse existing L-metal at all roof to wall flashings. L-metal will be 3 coursed with roof cement and membrane at bottom edge of metal. Reuse existing gutters and downspouts where existing. Furnish all necessary permits, driveway, landscaping, and pool screen protection. Furnish 5 year workmanship warranty from Buckner Roofing, LLC. Furnish 15 year wind warrany and 25 year algae warranty from GAF.
Work date2023-11-14
Status-
Source record ID20231174177
JurisdictionCharlotte County Accela Building jurisdiction

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_d6d71fafa900109ef1d0
Firm IDfirm_39200dd7aa7ba0e95ebc
Local Identity IDidentity_98c3a5520a7d3a7330e9
Portal Keycharlotte_accela
Jurisdiction ScopeCharlotte County Accela Building jurisdiction
Source Record ID20231174177
Work Event ID20231174177
Work TypeResidential Roofing
Work Categoryroofing
DescriptionTear-off existing shingle roofing to bare plywood deck, roofer to despose of debris. Replace rotten plywood, structural lumber, and fascia boards as necessary.*** Re-nail existing plywood deck 6" o.c. with 8d ring shank nails per building code. Furnish and Install Apoc SB-1 self adhered underlayment direct to plywood deck. Furnish and Install GAF Seal-A-Ridge hip and ridge caps. Furnish and Install GAF Strip at all eaves. Furnish and Install all necesssary flashings for a complete roofing system. Furnish and Install 26 gauge drip edge with standard paint finish at all eaves and rakes. Furnish and Install 26 gauge valley metal at all valleys. Furnish and Install GAF Rigid Vent 3 ridge ventilation where currently existing. Furnish and Install lead pipe boots at all sewer stacks. Furnish and Install 26 gauge gooseneck vents at all dryer and kitchen vent locations. Paint all lead pipe boots, dryer vents, and kitchen vents to match shingle color. Reuse existing L-metal at all roof to wall flashings. L-metal will be 3 coursed with roof cement and membrane at bottom edge of metal. Reuse existing gutters and downspouts where existing. Furnish all necessary permits, driveway, landscaping, and pool screen protection. Furnish 5 year workmanship warranty from Buckner Roofing, LLC. Furnish 15 year wind warrany and 25 year algae warranty from GAF.
Observed Project Value18,625
Value Typeunknown
Value SourceCharlotte Accela Construction Cost
Value Confidencemedium
Work Date2023-11-14
Status-
Site Address24500 BUCKINGHAM WAY, PORT CHARLOTTE FL 33980
City-
StateFL
Postal Code-
CountyCharlotte
Parcel ID402307276006
Latitude-
Longitude-
Source URLhttps://aca-prod.accela.com/BOCC/Cap/CapDetail.aspx?Module=Building&TabName=Building&ca...
Raw Payload Pathartifacts/business-backfills/charlotte_accela/run_date=2026-06-05/11-14-2023_11-14-2023_type-all_pages-50_details-all.json
Imported At2026-06-05
Source Fields
{
  "business_display_name": "NATHANIEL W BUCKNER",
  "city": null,
  "confidence_notes": "Live Accela date-window import; value and contractor parsed from public CapDetail page.",
  "county": "Charlotte",
  "description": "Tear-off existing shingle roofing to bare plywood deck, roofer to despose of debris.\r\nReplace rotten plywood, structural lumber, and fascia boards as necessary.***\r\nRe-nail existing plywood deck 6\" o.c. with 8d ring shank nails per building code.\r\nFurnish and Install Apoc SB-1 self adhered underlayment direct to plywood deck.\r\nFurnish and Install GAF Seal-A-Ridge hip and ridge caps.\r\nFurnish and Install GAF Strip at all eaves.\r\nFurnish and Install all necesssary flashings for a complete roofing system.\r\nFurnish and Install 26 gauge drip edge with standard paint finish at all eaves and rakes.\r\nFurnish and Install 26 gauge valley metal at all valleys.\r\nFurnish and Install GAF Rigid Vent 3 ridge ventilation where currently existing.\r\nFurnish and Install lead pipe boots at all sewer stacks.\r\nFurnish and Install 26 gauge gooseneck vents at all dryer and kitchen vent locations.\r\nPaint all lead pipe boots, dryer vents, and kitchen vents to match shingle color.\r\nReuse existing L-metal at all roof to wall flashings. L-metal will be 3 coursed with\r\nroof cement and membrane at bottom edge of metal.\r\nReuse existing gutters and downspouts where existing.\r\nFurnish all necessary permits, driveway, landscaping, and pool screen protection.\r\nFurnish 5 year workmanship warranty from Buckner Roofing, LLC.\r\nFurnish 15 year wind warrany and 25 year algae warranty from GAF.",
  "email": null,
  "insurance_or_bond_summary": null,
  "jurisdiction_scope": "Charlotte County Accela Building jurisdiction",
  "legal_or_dba_name": "NATHANIEL W BUCKNER",
  "license_number": "CCC1334407",
  "license_status": null,
  "license_type": "NORTH FORT MYERS, FL, 33903 | C ROOFING  CCC1334407",
  "mailing_or_firm_address": "BUCKNER ROOFING LLC",
  "parcel_id": "402307276006",
  "phone": "2399802837",
  "portal_key": "charlotte_accela",
  "postal_code": null,
  "qualifier_name": "LEE",
  "raw_payload_path": "artifacts/business-backfills/charlotte_accela/run_date=2026-06-05/11-14-2023_11-14-2023_type-all_pages-50_details-all.json",
  "scope_layer": "county_permitting_authority",
  "site_address": "24500 BUCKINGHAM WAY, PORT CHARLOTTE FL 33980",
  "source_fields": {
    "detail": {
      "detail_text_sample": "Accela Citizen Access\nLogin\nRegister for an Account\n|\nAnnouncements\n(\n)\n|\nMark as Read\nmore\nmore\nMessage Bar\nPermit\n20231174177\n:\nResidential Roofing\nRecord Status:\nClosed\nCreate a New Collection\n*\nName:\nDescription:\nAdd\nCancel\nRecord Info\nPermit Details\nReview Status\nRelated Permits\nAttachments\nInspections\nValuation Calculator\nPayments\nFees\nTrust Account Information\nConditions\nMore...\nCustom Component\nView your\nPlan Review\ncomments by clicking the \"Record Info\" menu above then select \"Review Status\".\nIMPORTANT:\nView and print your\nJOB CARD\nby clicking the \"Print/View Job Card\" button at the bottom of the screen.\nNote:  You\nmust be logged in to the permitting site\nto print or view your Job Card.\nJob Site Location:\n24500 BUCKINGHAM WAY\nPORT CHARLOTTE FL 33980\nADDRESSKEY: 227062\nADDID: 304122\nHISTORICAL: N\n*\nPermit Details\nApplicant:\nNATHANIEL\nW\nBUCKNER\nBUCKNER ROOFING LLC\n984 JOLLY RD\nNORTH FORT MYERS,\nFL,\n33903\nHome Phone:\n2399802837\[email protected]\nLicensed Professional:\nNATHANIEL W BUCKNER\nBUCKNER ROOFING LLC\nLEE\n984 JOLLY RD\nNORTH FORT MYERS, FL, 33903\nHome Phone:\n2399802837\nC ROOFING  CCC1334407\nJob Description:\nTear-off existing shingle roofing to bare plywood deck, roofer to despose of debris.\nReplace rotten plywood, structural lumber, and fascia boards as necessary.***\nRe-nail existing plywood deck 6\" o.c. with 8d ring shank nails per building code.\nFurnish and Install Apoc SB-1 self adhered underlayment direct to plywood deck.\nFurnish and Install GAF Seal-A-Ridge hip and ridge caps.\nFurnish and Install GAF Strip at all eaves.\nFurnish and Install all necesssary flashings for a complete roofing system.\nFurnish and Install 26 gauge drip edge with standard paint finish at all eaves and rakes.\nFurnish and Install 26 gauge valley metal at all valleys.\nFurnish and Install GAF Rigid Vent 3 ridge ventilation where currently existing.\nFurnish and Install lead pipe boots at all sewer stacks.\nFurnish and Install 26 gauge gooseneck vents at all dryer and kitchen vent locations.\nPaint all lead pipe boots, dryer vents, and kitchen vents to match shingle color.\nReuse existing L-metal at all roof to wall flashings. L-metal will be 3 coursed with\nroof cement and membrane at bottom edge of metal.\nReuse existing gutters and downspouts where existing.\nFurnish all necessary permits, driveway, landscaping, and pool screen protection.\nFurnish 5 year workmanship warranty from Buckner Roofing, LLC.\nFurnish 15 year wind warrany and 25 year algae warranty from GAF.\nOwner:\nCASEY JAMES A & TRACY REIFF-CASEY\n*\n24500 BUCKINGHAM WAY\nPORT CHARLOTTE FL 33980\nMore Details\nRelated Contacts\nOwner information\nW\nPORT CHARLOTTE, FL, 33980\nOwner information\nW\nPORT CHARLOTTE, FL, 33980\nApplication Information\nGENERAL\nInspection Notification Options:\nReceive EMAIL and TEXT\nExpiration Date:\n6/24/2024\nConstruction Cost:\n18625\nStorm related repair/replacement?:\nNo\nStorm Name:\nNot Applicable\nROOF DISCLAIMER\nCheck to confirm you have read and accept the above disclaimer:\nYes\nROOF DISCLAIMER II\nCheck to confirm you have read and accept the above disclaimer:\nYes\nROOF COVERING\nValuation is under $300,000:\nYes\nINSTALLATION DETAILS\nRoof Installation Type:\nReplacement\nType of Roof:\nShingle\n*Tile Roof Disclaimer: By accepting this disclaimer, you certify that the roof framing and diaphragm, in its current condition, are capable of withstanding the loads from the tile roof installation:\nYes\nSlope:\n6:12\n# of Squares:\n27.5\nManufacturer:\nGAF\nSpec #:\nFL10124-R32\nInsulation & Type:\nShingle\nParcel Information\nParcel Number:402307276006\n*\nBlock:0028\nLot:0037\nSubdivision:KGG\nBLDG_TOTAL_AREA: 2210\nDOC_EXEMPT: N\nLAND_USE: Single Family Residential\nASSESSED_VALUE: 144476\nPARCEL_ACRES: 0\nTAX_DISTRICT: 104\nACLF: N\nTURTLEZONE: OUT\nFZONE: X\nSFHA: OUT\nFLOODWAY: OUT\nNAME_DRI: Victoria Estates\nIDNUM_BIT: 33\nL1_SUBDIVISION: KGG\nISLAND: undefined\nFees\nLoading...\nInspections\nThe inspections specific to your job are listed below under \"Upcoming Inspections\" with a status of \"Pendin",
      "job_value": "18625",
      "licensed_professional": {
        "city_state_zip": "984 JOLLY RD",
        "company": "NATHANIEL W BUCKNER",
        "license_holder": "LEE",
        "license_notes": "NORTH FORT MYERS, FL, 33903 | C ROOFING  CCC1334407",
        "phones": {
          "home_phone": "2399802837"
        },
        "street_address": "BUCKNER ROOFING LLC"
      },
      "licensed_professional_raw": "NATHANIEL W BUCKNER | BUCKNER ROOFING LLC | LEE | 984 JOLLY RD | NORTH FORT MYERS, FL, 33903 | Home Phone: 2399802837 | C ROOFING  CCC1334407",
      "owner": "CASEY JAMES A & TRACY REIFF-CASEY",
      "pcn": "402307276006",
      "value_label": "Construction Cost"
    },
    "grid_cells": [
      "",
      "11/14/2023",
      "20231174177",
      "Residential Roofing",
      "Tear-off existing shingle roofing to bare plywood deck, roofer to despose of debris.\r\nReplace rotten plywood, structural lumber, and fascia boards as necessary.***\r\nRe-nail existing plywood deck 6\" o.c. with 8d ring shank nails per building code.\r\nFurnish and Install Apoc SB-1 self adhered underlayment direct to plywood deck.\r\nFurnish and Install GAF Seal-A-Ridge hip and ridge caps.\r\nFurnish and Install GAF Strip at all eaves.\r\nFurnish and Install all necesssary flashings for a complete roofing system.\r\nFurnish and Install 26 gauge drip edge with standard paint finish at all eaves and rakes.\r\nFurnish and Install 26 gauge valley metal at all valleys.\r\nFurnish and Install GAF Rigid Vent 3 ridge ventilation where currently existing.\r\nFurnish and Install lead pipe boots at all sewer stacks.\r\nFurnish and Install 26 gauge gooseneck vents at all dryer and kitchen vent locations.\r\nPaint all lead pipe boots, dryer vents, and kitchen vents to match shingle color.\r\nReuse existing L-metal at all roof to wall flashings. L-metal will be 3 coursed with\r\nroof cement and membrane at bottom edge of metal.\r\nReuse existing gutters and downspouts where existing.\r\nFurnish all necessary permits, driveway, landscaping, and pool screen protection.\r\nFurnish 5 year workmanship warranty from Buckner Roofing, LLC.\r\nFurnish 15 year wind warrany and 25 year algae warranty from GAF.",
      "Closed",
      "24500 BUCKINGHAM WAY, PORT CHARLOTTE FL 33980",
      "",
      "24500 BUCKINGHAM WAY, PORT CHARLOTTE FL 33980"
    ],
    "grid_inferred": {
      "application_date": "11/14/2023",
      "description": "Tear-off existing shingle roofing to bare plywood deck, roofer to despose of debris.\r\nReplace rotten plywood, structural lumber, and fascia boards as necessary.***\r\nRe-nail existing plywood deck 6\" o.c. with 8d ring shank nails per building code.\r\nFurnish and Install Apoc SB-1 self adhered underlayment direct to plywood deck.\r\nFurnish and Install GAF Seal-A-Ridge hip and ridge caps.\r\nFurnish and Install GAF Strip at all eaves.\r\nFurnish and Install all necesssary flashings for a complete roofing system.\r\nFurnish and Install 26 gauge drip edge with standard paint finish at all eaves and rakes.\r\nFurnish and Install 26 gauge valley metal at all valleys.\r\nFurnish and Install GAF Rigid Vent 3 ridge ventilation where currently existing.\r\nFurnish and Install lead pipe boots at all sewer stacks.\r\nFurnish and Install 26 gauge gooseneck vents at all dryer and kitchen vent locations.\r\nPaint all lead pipe boots, dryer vents, and kitchen vents to match shingle color.\r\nReuse existing L-metal at all roof to wall flashings. L-metal will be 3 coursed with\r\nroof cement and membrane at bottom edge of metal.\r\nReuse existing gutters and downspouts where existing.\r\nFurnish all necessary permits, driveway, landscaping, and pool screen protection.\r\nFurnish 5 year workmanship warranty from Buckner Roofing, LLC.\r\nFurnish 15 year wind warrany and 25 year algae warranty from GAF.",
      "record_type": "Residential Roofing",
      "site_address": "24500 BUCKINGHAM WAY, PORT CHARLOTTE FL 33980",
      "status": null
    },
    "work_category": "roofing"
  },
  "source_record_id": "20231174177",
  "source_url": "https://aca-prod.accela.com/BOCC/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=23ROO&capID2=00000&capID3=24406&agencyCode=BOCC&IsToShowInspection=",
  "state": "FL",
  "status": null,
  "work_date": "2023-11-14",
  "work_event_id": "20231174177",
  "work_type": "Residential Roofing",
  "work_value": 18625,
  "work_value_source": "Charlotte Accela Construction Cost"
}
Get this page with API

Rendered from the bluedoor Licensed Contractors API. Reproduce it:

GET https://api.bluedoor.sh/licensed-contractors/v1/work-events/event_d6d71fafa900109ef1d0?include_source_fields=trueJSON
Tear-off existing shingle roofing to bare plywood deck, roofer to d... — Licensed Contractors data | bluedoor