bluedoor data·Licensed Contractors API·bluedoor.sh ↗

HomeWork eventsResidential Permit (Single Family Residence, New Work)

Residential Permit (Single Family Residence, New Work)

Residential Building event dated 2000-06-22.

Work event

Work event PKevent_d001109a514921900df8
Work typeResidential Permit (Single Family Residence, New Work)
Work categoryResidential Building
Description-
Work date2000-06-22
StatusCert of Occupancy
Source record ID380543:Pre-fabricated Shed Installer:20000526015
JurisdictionVolusia Connect Live / AMANDA portal jurisdiction

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_d001109a514921900df8
Firm IDfirm_999a9d9921e3065458a6
Local Identity IDidentity_8bac45e5f24bf56fff66
Portal Keyvolusia_amanda
Jurisdiction ScopeVolusia Connect Live / AMANDA portal jurisdiction
Source Record ID380543:Pre-fabricated Shed Installer:20000526015
Work Event ID20000526015
Work TypeResidential Permit (Single Family Residence, New Work)
Work Categoryresidential_building
Description-
Observed Project Value50,000
Value Typedeclared_value
Value SourceVolusia AMANDA Additional Information Declared Construction Cost
Value Confidencehigh
Work Date2000-06-22
StatusCert of Occupancy
Site Address1114 Delaware Av, Deland
City-
StateFL
Postal Code-
CountyVolusia
Parcel ID-
Latitude-
Longitude-
Source URLhttps://connectlivepermits.org/citizenportal/app/
Raw Payload Pathartifacts/business-layer-samples/volusia_amanda/run_date=2026-06-05/raw/associated_refs_before_2017_after_any/folder_reference_details.json
Imported At2026-06-05
Source Fields
{
  "business_display_name": "R S B Homes Inc",
  "city": "",
  "confidence_notes": "Parsed from Volusia AMANDA Open Folders, Record Details, People Details, and Additional Information public endpoints. State license enriched from exact normalized ContractorList business-name match.",
  "county": "Volusia",
  "description": "",
  "email": "",
  "insurance_or_bond_summary": "",
  "jurisdiction_scope": "Volusia Connect Live / AMANDA portal jurisdiction",
  "legal_or_dba_name": "R S B Homes Inc",
  "license_number": "CBC042299",
  "license_status": "Not Current",
  "license_type": "BUILDING CONTRACTOR-CLASS B",
  "mailing_or_firm_address": "Mr. Robert Bailey,R S B Homes Inc 1790 Kim Denise Ct.",
  "parcel_id": "",
  "phone": "",
  "portal_key": "volusia_amanda",
  "postal_code": "",
  "qualifier_name": "Robert Bailey",
  "raw_payload_path": "artifacts/business-layer-samples/volusia_amanda/run_date=2026-06-05/raw/associated_refs_before_2017_after_any/folder_reference_details.json",
  "scope_layer": "county_permitting_authority",
  "site_address": "1114 Delaware Av, Deland",
  "source_fields": {
    "additional_info": [
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Jurisdiction",
        "name": "50000",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"County\",\"value\":\"County\"},{\"label\":\"Daytona Beach\",\"value\":\"Daytona Beach\"},{\"label\":\"Daytona Beach Shores\",\"value\":\"Daytona Beach Shores\"},{\"label\":\"DeBary\",\"value\":\"DeBary\"},{\"label\":\"DeLand\",\"value\":\"DeLand\"},{\"label\":\"Deltona\",\"value\":\"Deltona\"},{\"label\":\"Edgewater\",\"value\":\"Edgewater\"},{\"label\":\"Flagler Beach\",\"value\":\"Flagler Beach\"},{\"label\":\"Holly Hill\",\"value\":\"Holly Hill\"},{\"label\":\"Lake Helen\",\"value\":\"Lake Helen\"},{\"label\":\"New Smyrna Beach\",\"value\":\"New Smyrna Beach\"},{\"label\":\"Oak Hill\",\"value\":\"Oak Hill\"},{\"label\":\"Orange City\",\"value\":\"Orange City\"},{\"label\":\"Ormond Beach\",\"value\":\"Ormond Beach\"},{\"label\":\"Pierson\",\"value\":\"Pierson\"},{\"label\":\"Ponce Inlet\",\"value\":\"Ponce Inlet\"},{\"label\":\"Port Orange\",\"value\":\"Port Orange\"},{\"label\":\"South Daytona\",\"value\":\"South Daytona\"}]",
        "readonly": "Y",
        "title": "Jurisdiction",
        "type": "C",
        "value": "County"
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Electrical Information",
        "groupHelp": "",
        "label": "Electrical work proposed?",
        "name": "50475",
        "options": "",
        "readonly": "Y",
        "title": "Electrical work proposed?",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "25",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Electrical Information",
        "groupHelp": "",
        "label": "Power Company",
        "name": "51130",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Clay/Palatka\",\"value\":\"Clay/Palatka\"},{\"label\":\"Clay/Salt Springs\",\"value\":\"Clay/Salt Springs\"},{\"label\":\"Duke Energy\",\"value\":\"Duke Energy\"},{\"label\":\"FL Power and Light North\",\"value\":\"FL Power and Light North\"},{\"label\":\"FL Power and Light South\",\"value\":\"FL Power and Light South\"},{\"label\":\"NSB Utilities\",\"value\":\"NSB Utilities\"},{\"label\":\"Titusville\",\"value\":\"Titusville\"}]",
        "readonly": "Y",
        "title": "Power Company",
        "type": "C",
        "value": "Progress Energy"
      },
      {
        "DisplayOrder": "45",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Electrical Information",
        "groupHelp": "",
        "label": "New Amperage",
        "name": "51105",
        "options": "",
        "readonly": "Y",
        "title": "New Amperage",
        "type": "N",
        "value": "150"
      },
      {
        "DisplayOrder": "55",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Electrical Information",
        "groupHelp": "",
        "label": "New Phase",
        "name": "51115",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Phase 1\",\"value\":\"Phase 1\"},{\"label\":\"Phase 3\",\"value\":\"Phase 3\"}]",
        "readonly": "Y",
        "title": "New Phase",
        "type": "C",
        "value": "Phase 1"
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "HVAC Information",
        "groupHelp": "",
        "label": "HVAC work proposed?",
        "name": "51929",
        "options": "",
        "readonly": "Y",
        "title": "HVAC work proposed?",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "HVAC Information",
        "groupHelp": "",
        "label": "Electric",
        "name": "51930",
        "options": "",
        "readonly": "Y",
        "title": "Electric",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "15",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "HVAC Information",
        "groupHelp": "",
        "label": "Gas",
        "name": "51935",
        "options": "",
        "readonly": "Y",
        "title": "Gas",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "20",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "HVAC Information",
        "groupHelp": "",
        "label": "Oil",
        "name": "51940",
        "options": "",
        "readonly": "Y",
        "title": "Oil",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "25",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "HVAC Information",
        "groupHelp": "",
        "label": "Heat Pump",
        "name": "51950",
        "options": "",
        "readonly": "Y",
        "title": "Heat Pump",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "30",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "HVAC Information",
        "groupHelp": "",
        "label": "A/C",
        "name": "51955",
        "options": "",
        "readonly": "Y",
        "title": "A/C",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "35",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "HVAC Information",
        "groupHelp": "",
        "label": "Declared HVAC Cost",
        "name": "51960",
        "options": "",
        "readonly": "Y",
        "title": "Declared HVAC Cost",
        "type": "N",
        "value": "3500"
      },
      {
        "DisplayOrder": "2",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Plumbing Information",
        "groupHelp": "",
        "label": "Plumbing work proposed?",
        "name": "52060",
        "options": "",
        "readonly": "Y",
        "title": "Plumbing work proposed?",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "Enter the number of new plumbing fixtures",
        "columnClass": "col-md-6",
        "group": "Plumbing Information",
        "groupHelp": "",
        "label": "Plumbing Fixtures",
        "name": "51355",
        "options": "",
        "readonly": "Y",
        "title": "Plumbing Fixtures",
        "type": "N",
        "value": "5"
      },
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Plumbing Information",
        "groupHelp": "",
        "label": "Sewer/Septic Connections",
        "name": "51360",
        "options": "",
        "readonly": "Y",
        "title": "Sewer/Septic Connections",
        "type": "N",
        "value": "11"
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Flood Zone Information",
        "groupHelp": "",
        "label": "Floodzone",
        "name": "51480",
        "options": "",
        "readonly": "Y",
        "title": "Floodzone",
        "type": "A",
        "value": "B/C"
      },
      {
        "DisplayOrder": "15",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Construction Costs",
        "groupHelp": "",
        "label": "Declared Construction Cost",
        "name": "50405",
        "options": "",
        "readonly": "Y",
        "title": "Declared Construction Cost",
        "type": "N",
        "value": "50000"
      },
      {
        "DisplayOrder": "40",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "Selecting No will add a Floor Variance Review to the application",
        "columnClass": "col-md-6",
        "group": "Permit Information",
        "groupHelp": "",
        "label": "Low Floor Level >= 12\" above Adj Roads?",
        "name": "51970",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"N/A\",\"value\":\"N/A\"},{\"label\":\"No\",\"value\":\"No\"},{\"label\":\"Yes\",\"value\":\"Yes\"}]",
        "readonly": "Y",
        "title": "Low Floor Level >= 12\" above Adj Roads?",
        "type": "C",
        "value": "Yes"
      },
      {
        "DisplayOrder": "100",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Permit Information",
        "groupHelp": "",
        "label": "Grand Total Square Feet",
        "name": "53000",
        "options": "",
        "readonly": "Y",
        "title": "Grand Total Square Feet",
        "type": "N",
        "value": "1143"
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "Y",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Zoning & Land Use Information",
        "groupHelp": "",
        "label": "Current Zoning",
        "name": "30020",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"A-1\",\"value\":\"A-1\"},{\"label\":\"A-2\",\"value\":\"A-2\"},{\"label\":\"A-3\",\"value\":\"A-3\"},{\"label\":\"A-4\",\"value\":\"A-4\"},{\"label\":\"B-1\",\"value\":\"B-1\"},{\"label\":\"B-2\",\"value\":\"B-2\"},{\"label\":\"B-3\",\"value\":\"B-3\"},{\"label\":\"B-4\",\"value\":\"B-4\"},{\"label\":\"B-5\",\"value\":\"B-5\"},{\"label\":\"B-6\",\"value\":\"B-6\"},{\"label\":\"B-7\",\"value\":\"B-7\"},{\"label\":\"B-8\",\"value\":\"B-8\"},{\"label\":\"B-9\",\"value\":\"B-9\"},{\"label\":\"BPUD\",\"value\":\"BPUD\"},{\"label\":\"C\",\"value\":\"C\"},{\"label\":\"City\",\"value\":\"City\"},{\"label\":\"FR\",\"value\":\"FR\"},{\"label\":\"I-1\",\"value\":\"I-1\"},{\"label\":\"I-2\",\"value\":\"I-2\"},{\"label\":\"I-3\",\"value\":\"I-3\"},{\"label\":\"I-4\",\"value\":\"I-4\"},{\"label\":\"IPUD\",\"value\":\"IPUD\"},{\"label\":\"MH-1\",\"value\":\"MH-1\"},{\"label\":\"MH-2\",\"value\":\"MH-2\"},{\"label\":\"MH-3\",\"value\":\"MH-3\"},{\"label\":\"MH-4\",\"value\":\"MH-4\"},{\"label\":\"MH-5\",\"value\":\"MH-5\"},{\"label\":\"MH-6\",\"value\":\"MH-6\"},{\"label\":\"MH-7\",\"value\":\"MH-7\"},{\"label\":\"MH-8\",\"value\":\"MH-8\"},{\"label\":\"MPUD\",\"value\":\"MPUD\"},{\"label\":\"OCR\",\"value\":\"OCR\"},{\"label\":\"OCV\",\"value\":\"OCV\"},{\"label\":\"OMV\",\"value\":\"OMV\"},{\"label\":\"ORE\",\"value\":\"ORE\"},{\"label\":\"OTC\",\"value\":\"OTC\"},{\"label\":\"OTR\",\"value\":\"OTR\"},{\"label\":\"OUR\",\"value\":\"OUR\"},{\"label\":\"P\",\"value\":\"P\"},{\"label\":\"PUD\",\"value\":\"PUD\"},{\"label\":\"R-1\",\"value\":\"R-1\"},{\"label\":\"R-2\",\"value\":\"R-2\"},{\"label\":\"R-3\",\"value\":\"R-3\"},{\"label\":\"R-3W\",\"value\":\"R-3W\"},{\"label\":\"R-4\",\"value\":\"R-4\"},{\"label\":\"R-4W\",\"value\":\"R-4W\"},{\"label\":\"R-5\",\"value\":\"R-5\"},{\"label\":\"R-6\",\"value\":\"R-6\"},{\"label\":\"R-7\",\"value\":\"R-7\"},{\"label\":\"R-8\",\"value\":\"R-8\"},{\"label\":\"R-9\",\"value\":\"R-9\"},{\"label\":\"R-9W\",\"value\":\"R-9W\"},{\"label\":\"RA\",\"value\":\"RA\"},{\"label\":\"RC\",\"value\":\"RC\"},{\"label\":\"RE\",\"value\":\"RE\"},{\"label\":\"RPUD\",\"value\":\"RPUD\"},{\"label\":\"RR\",\"value\":\"RR\"},{\"label\":\"SWC\",\"value\":\"SWC\"},{\"label\":\"SWR\",\"value\":\"SWR\"}]",
        "readonly": "Y",
        "title": "Current Zoning",
        "type": "C",
        "value": "R5"
      },
      {
        "DisplayOrder": "30",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "Enter the septic permit number issued by the Health Department to expedite the review of your application.",
        "columnClass": "col-md-6",
        "group": "Related Permits",
        "groupHelp": "",
        "label": "Septic Permit #",
        "name": "50145",
        "options": "",
        "readonly": "Y",
        "title": "Septic Permit #",
        "type": "A",
        "value": "DEL001002N"
      }
    ],
    "open_folder": {
      "Actions": "Detail",
      "Date": "2000-05-26",
      "File Number": "00 104648 000 00 RES",
      "Folder Name": "1114 Delaware Av, Deland",
      "FolderRSN": "297293",
      "Reference File": "20000526015",
      "Type": "RES",
      "_id": "EpmIIXEqgxLHkURzUGuDIhuqJ/pyRA=="
    },
    "people": {
      "Address": "Mr. Robert Bailey,R S B Homes Inc 1790 Kim Denise Ct.",
      "First Name": "Robert",
      "Last Name": "Bailey",
      "People ID": "380543",
      "People Role": "Pre-fabricated Shed Installer",
      "PeopleRSN": "380543",
      "_id": "E5iPJnwq0UsbkylFqyt4lQwBGmbfrg=="
    },
    "record_detail": {
      "Application Date": "May 26, 2000",
      "Expiration Date": "March 25, 2001",
      "Folder Name": "1114 Delaware Av, Deland",
      "Issue Date": "June 22, 2000",
      "Reference Number": "20000526015",
      "Status": "Cert of Occupancy",
      "Type": "Residential Permit (Single Family Residence, New Work)",
      "[FullRow]": " ",
      "[FullRow]Condition": "EXISTING HOUSE TO BE DEMOLISHED     REMOVED IMPACTS  MMR\n\nSFR NEW SEPTIC ON CITY WATER NEW DRIVEWAY\n\nMOVE EXISTING SHED TO NEW LOCATION.\n\n                         N O T I C E\n\n                 ASBETOS NOTIFICATION STATEMENT\n\nIT IS THE OWNER, OPERATORS, AND CONTRACTORS RESPONSIBILITY\n\nTO COMPLY WITH THE PROVISIONS OF F.S.455.302 AND TO\n\nNOTIFY THE DEPARTMENT OF ENVIRONMENTAL PROTECTION (DEP) OF\n\nANY INTENTIONS TO REMOVE FROM ANY BUILDING OR STRUCTURE.\n\n           DEP  407-894-7555\n\n<SHED> INSPECTION FOR NEW SLAB FOR EXISTING SHED MOVED TO\n\n NEW LOCATION PER PLOT PLAN AND BID ADDENDUM. MINIMUM 8 \"\n\n THICKEN EDGE SLAB WITH ONE (1) #3 REINF. BAR CONTINOUS.\n\n*** NOTICE OF COMMENCEMENT REQUIRED ***\n\n",
      "[FullRow]Description": ""
    },
    "registry_license_match": {
      "license_number": "CBC042299",
      "license_status": "Not Current",
      "license_type": "BUILDING CONTRACTOR-CLASS B",
      "normalized_license_number": "CBC042299"
    }
  },
  "source_record_id": "380543:Pre-fabricated Shed Installer:20000526015",
  "source_url": "https://connectlivepermits.org/citizenportal/app/",
  "state": "FL",
  "status": "Cert of Occupancy",
  "work_date": "June 22, 2000",
  "work_event_id": "20000526015",
  "work_type": "Residential Permit (Single Family Residence, New Work)",
  "work_value": "50000",
  "work_value_source": "Volusia AMANDA Additional Information Declared Construction Cost"
}
Get this page with API

Rendered from the bluedoor Licensed Contractors API. Reproduce it:

GET https://api.bluedoor.sh/licensed-contractors/v1/work-events/event_d001109a514921900df8?include_source_fields=trueJSON
Residential Permit (Single Family Residence, New Work) — Licensed Contractors data | bluedoor