Home › Work events › RENEWED 5-9-25 (180 DAYS) Per state of emergency -Milton The antenna system will be re-...
RENEWED 5-9-25 (180 DAYS) Per state of emergency -Milton The antenna system will be re-...
Commercial Building event dated 2024-03-14.
Work event
| Work event PK | event_af9e1cbe03b4bd8bd44a |
| Work type | Commercial Antenna |
| Work category | Commercial Building |
| Description | RENEWED 5-9-25 (180 DAYS) Per state of emergency -Milton The antenna system will be re-installed at the new site with a center of radiation of 657 ft AGL. The structural analysis shows that a 30 ft tower section which includes T33 to T30 extends from flanges at 650.5 ft to 680.5 ft with horizontals at 7.5 ft increments. This puts the antennas beginning just above the flange at 650 ft which is two flanges below the guy wire at 725 ft. The two sets of antennas will be pointed at 340 degrees true (348 magnetic) on the A (north) leg and 184 degrees true (192 magnetic) on the C (SW) leg. The north (340 deg) set will have the same beam tilt as before. The same power divider, and connection scheme above will be used: (A 4 way unequal split power divider with four feedlines, two of one phase (shorter) to the top antennas and two of another phase (longer) to the bottom antennas on the two sets is used. The northern set of antennas takes the lower power output ports and the southern set of antennas takes the higher power output ports.)New cables will be provided to ensure they are not damaged and have room to be held in place on this significantly larger tower. The power divider must be solidly mounted and bolted to the tower using the brackets from the old tower. This power divider has a DIN 7-16 input connector. Note that the solid rod leg diameters at the antenna mounting height are 5-3/4”. |
| Work date | 2024-03-14 |
| Status | Closed-Certificate Issued |
| Source record ID | BLD2024030736 |
| Jurisdiction | Martin County Accela Building jurisdiction |
Location
| Site address | - |
| City | - |
| County | - |
| State | - |
| Postal code | - |
| Parcel ID | - |
| Latitude | - |
| Longitude | - |
Project value
| Amount | - |
| Type | - |
| Source | - |
| Confidence | - |
Provenance
| Source URL | - |
| Raw payload path | - |
| Imported at | - |
Full work-event record
| Work Event PK | event_af9e1cbe03b4bd8bd44a |
| Firm ID | firm_01fee9318e653ad74f07 |
| Local Identity ID | identity_5c321e15323bd6c9789b |
| Portal Key | martin_accela |
| Jurisdiction Scope | Martin County Accela Building jurisdiction |
| Source Record ID | BLD2024030736 |
| Work Event ID | BLD2024030736 |
| Work Type | Commercial Antenna |
| Work Category | commercial_building |
| Description | RENEWED 5-9-25 (180 DAYS) Per state of emergency -Milton The antenna system will be re-installed at the new site with a center of radiation of 657 ft AGL. The structural analysis shows that a 30 ft tower section which includes T33 to T30 extends from flanges at 650.5 ft to 680.5 ft with horizontals at 7.5 ft increments. This puts the antennas beginning just above the flange at 650 ft which is two flanges below the guy wire at 725 ft. The two sets of antennas will be pointed at 340 degrees true (348 magnetic) on the A (north) leg and 184 degrees true (192 magnetic) on the C (SW) leg. The north (340 deg) set will have the same beam tilt as before. The same power divider, and connection scheme above will be used: (A 4 way unequal split power divider with four feedlines, two of one phase (shorter) to the top antennas and two of another phase (longer) to the bottom antennas on the two sets is used. The northern set of antennas takes the lower power output ports and the southern set of antennas takes the higher power output ports.)New cables will be provided to ensure they are not damaged and have room to be held in place on this significantly larger tower. The power divider must be solidly mounted and bolted to the tower using the brackets from the old tower. This power divider has a DIN 7-16 input connector. Note that the solid rod leg diameters at the antenna mounting height are 5-3/4”. |
| Observed Project Value | 8,320 |
| Value Type | job_value |
| Value Source | Martin Accela JobValue |
| Value Confidence | high |
| Work Date | 2024-03-14 |
| Status | Closed-Certificate Issued |
| Site Address | 3350 SE BRIDGE RD, HOBE SOUND FL 33455 |
| City | HOBE SOUND |
| State | FL |
| Postal Code | 33455 |
| County | Martin |
| Parcel ID | 06-40-42-000-000-00011-0 |
| Latitude | 27.026 |
| Longitude | -80.177 |
| Source URL | https://aca-prod.accela.com/MARTINCO/Cap/CapDetail.aspx?Module=Building&TabName=Buildin... |
| Raw Payload Path | - |
| Imported At | 2026-06-03 |
Source Fields
{
"business_display_name": "SERGE'S HOME INSPECTION INC",
"city": "HOBE SOUND",
"confidence_notes": "Imported from existing Martin Accela permit detail table.",
"county": "Martin",
"description": "RENEWED 5-9-25 (180 DAYS)\r\nPer state of emergency -Milton\r\n\r\nThe antenna system will be re-installed at the new site with a center of radiation of 657 ft AGL. The structural analysis shows that a 30 ft tower section which includes T33 to T30 extends from flanges at 650.5 ft to 680.5 ft with horizontals at 7.5 ft increments. This puts the antennas beginning just above the flange at 650 ft which is two flanges below the guy wire at 725 ft. The two sets of antennas will be pointed at 340 degrees true (348 magnetic) on the A (north) leg and 184 degrees true (192 magnetic) on the C (SW) leg. The north (340 deg) set will have the same beam tilt as before. The same power divider, and connection scheme above will be used: (A 4 way unequal split power divider with four feedlines, two of one phase (shorter) to the top antennas and two of another phase (longer) to the bottom antennas on the two sets is used. The northern set of antennas takes the lower power output ports and the southern set of antennas takes the higher power output ports.)New cables will be provided to ensure they are not damaged and have room to be held in place on this significantly larger tower. The power divider must be solidly mounted and bolted to the tower using the brackets from the old tower. This power divider has a DIN 7-16 input connector. Note that the solid rod leg diameters at the antenna mounting height are 5-3/4”.",
"email": "[email protected]",
"insurance_or_bond_summary": null,
"jurisdiction_scope": "Martin County Accela Building jurisdiction",
"latitude": 27.0262879959983,
"legal_or_dba_name": "SERGE'S HOME INSPECTION INC",
"license_number": "CGC1516181",
"license_status": null,
"license_type": "STATE CERT - GENERAL CONTRACTOR CGC1516181",
"longitude": -80.1771102075907,
"mailing_or_firm_address": "2040 NE 1ST AVE POMPANO BEACH FL 33060",
"parcel_id": "06-40-42-000-000-00011-0",
"phone": "7542352020",
"portal_key": "martin_accela",
"postal_code": "33455",
"qualifier_name": "MORISSAINT, SERGE",
"raw_payload_path": null,
"scope_layer": "county_permitting_authority",
"site_address": "3350 SE BRIDGE RD, HOBE SOUND FL 33455",
"source_record_id": "BLD2024030736",
"source_url": "https://aca-prod.accela.com/MARTINCO/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=REC24&capID2=00000&capID3=005D3&agencyCode=MARTINCO&IsToShowInspection=",
"state": "FL",
"status": "Closed-Certificate Issued",
"work_date": "2024-03-14",
"work_event_id": "BLD2024030736",
"work_type": "Commercial Antenna",
"work_value": 8320,
"work_value_source": "Martin Accela JobValue"
}Get this page with API