bluedoor data·Licensed Contractors API·bluedoor.sh ↗

HomeWork eventsreplacing existing hvac equipment with 3 ton 15.60 system

replacing existing hvac equipment with 3 ton 15.60 system

Hvac event dated 2023-07-07.

Work event

Work event PKevent_985e635c379dd1d1b34d
Work typereplacing existing hvac equipment with 3 ton 15.60 system
Work categoryHvac
Descriptionreplacing existing hvac equipment with 3 ton 15.60 system
Work date2023-07-07
StatusPermit Expired
Source record IDMEC2023-05376
JurisdictionLee County Accela Permitting jurisdiction

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_985e635c379dd1d1b34d
Firm IDfirm_a13d16d23f390aa14eba
Local Identity IDidentity_76b3768b8997de36fbce
Portal Keylee_accela
Jurisdiction ScopeLee County Accela Permitting jurisdiction
Source Record IDMEC2023-05376
Work Event IDMEC2023-05376
Work Typereplacing existing hvac equipment with 3 ton 15.60 system
Work Categoryhvac
Descriptionreplacing existing hvac equipment with 3 ton 15.60 system
Observed Project Value8,000
Value Typevaluation
Value SourceLee Accela Valuation
Value Confidencehigh
Work Date2023-07-07
StatusPermit Expired
Site Address12510 WORLD PLAZA LN, 2, FORT MYERS FL 33907
City-
StateFL
Postal Code-
CountyLee
Parcel ID14452447000000412
Latitude-
Longitude-
Source URLhttps://aca-prod.accela.com/LEECO/Cap/CapDetail.aspx?Module=Permitting&TabName=Permitti...
Raw Payload Pathartifacts/business-backfills/lee_accela/run_date=2026-06-03/07-07-2023_07-07-2023_type-all_pages-50_details-all.json
Imported At2026-06-03
Source Fields
{
  "business_display_name": "WILLIAM R TAYLOR",
  "city": null,
  "confidence_notes": "Live Accela date-window import; value and contractor parsed from public CapDetail page.",
  "county": "Lee",
  "description": "replacing existing hvac equipment with 3 ton 15.60 system",
  "email": null,
  "insurance_or_bond_summary": null,
  "jurisdiction_scope": "Lee County Accela Permitting jurisdiction",
  "legal_or_dba_name": "WILLIAM R TAYLOR",
  "license_number": "CAC048106",
  "license_status": null,
  "license_type": "Certified Air Cond Contractor  CAC048106",
  "mailing_or_firm_address": "CALOOSA COOLING LEE COUNTY LLC FORT MYERS FL 33901",
  "parcel_id": "14452447000000412",
  "phone": null,
  "portal_key": "lee_accela",
  "postal_code": null,
  "qualifier_name": "2760 BRAMAN AVE UNIT 2",
  "raw_payload_path": "artifacts/business-backfills/lee_accela/run_date=2026-06-03/07-07-2023_07-07-2023_type-all_pages-50_details-all.json",
  "scope_layer": "county_permitting_authority",
  "site_address": "12510 WORLD PLAZA LN, 2, FORT MYERS FL 33907",
  "source_fields": {
    "detail": {
      "detail_text_sample": "Accela Citizen Access\nLogin\n|\nRegister for an Account\n|\nAnnouncements\n(\n)\n|\nMark as Read\nTip:\nThe Global Search can be used for quick searches, using a case number, address, strap number (no special characters), or license number.\nNew Record Creation & Document Uploading:\nReport Issues, Ask Questions, Provide Feedback, or Request Training\nhere\n.  For more information about uploading documents using our new Digital Projects feature, click\nhere\n.\nCredit Card & Payment Info:\nLee County Government staff will never call you and ask for credit card or other sensitive information. Please report all fraudulent activity to the Lee County Sheriff's Office Fraud Unit at 239-258-3292.\nmore\nmore\nMessage Bar\nRecord\nMEC2023-05376\n:\nMechanical\nRecord Status:\nPermit Expired\nCreate a New Collection\n*\nName:\nDescription:\nspell check\nAdd\nCancel\nRecord Info\nRecord Details\nProcessing Status\nRelated Records\nInspections\nPayments\nFees\nConditions\nWork Location\n12510 WORLD PLAZA LN\n2\nFORT MYERS FL 33907\n*\nRecord Details\nIMPORTANT NOTE:\nFor Record Dates (i.e. Received Date, Issued Date, Expiration Date and Finaled Date) or Certificates of Occupancy, Compliance & Use, click Reports at the top of the page, and select the appropriate report name.  Certificates of Occupancy, Compliance & Use are only available for records in Closed-CO Issued, Closed-CC Issued, and Closed-Cert of Use Issued, record status.\nApplicant:\nWilliam\nTaylor\nCALOOSA COOLING LEE COUNTY LLC\n14241 Jetport Loop W Ste 1\nFORT MYERS,\nFL,\n33913\nPrimary Phone:\n2392260202\nCell Phone:\n226\nAlternate Phone:\n0202\[email protected]\nLicensed Professional:\nWILLIAM R TAYLOR\nCALOOSA COOLING LEE COUNTY LLC\n2760 BRAMAN AVE UNIT 2\nFORT MYERS, FL, 33901\nPrimary Phone:\n2392260202\nCertified Air Cond Contractor  CAC048106\nProject Description:\nWORLD PLAZA II OFFICE CONDO SEC 4 OR3064/3819 + OR 3334 PG 1669 BLDG 41 STE 1\nreplacing existing hvac equipment with 3 ton 15.60 system\nMore Details\nRelated Contacts\nContact information\nWilliam\nTaylor\nCALOOSA COOLING LEE COUNTY LLC\n14241 Jetport Loop W Ste 1\nFORT MYERS, FL, 33913\nPrimary Phone:\n2392260202\nCell Phone:\n226\nAlternate Phone:\n0202\nE-mail:\[email protected]\nApplication Information\nOWNER BUILDER\nIs the permit being pulled as Owner-Builder?:\nNo\nDISASTER RECOVERY INFO\nIs the proposed work a result of hurricane damage?:\nNo\nGENERAL INFORMATION\nType of Permit:\nSplit System\nCommercial/Residential:\nCommercial\nValuation:\n8000\nNew/Replace/Other:\nReplacement\nPrivate Provider Plan Review?:\nNo\nPrivate Provider Inspections?:\nNo\nDirections:\nCourthouse\n1700 Monroe St, Fort Myers, FL 33901\nHead southeast on Monroe St toward Second St\n0.1 mi\nTurn right to stay on Monroe St\n0.2 mi\nTurn right onto Victoria Ave\n0.2 mi\nTurn left onto Cleveland Ave/US Hwy 41 S\nPass by Papa Johns Pizza (on the right in 1.5 mi)\n5.3 mi\nTurn right onto Brantley Rd\n0.4 mi\nTurn left onto World Plaza Ln\n118 ft\nTurn right\n72 ft\n12510 World Plaza Ln\nFort Myers, FL 33907\nApplication Information Table\nAC DETAILS\nType of System:\nSplit System\nAction:\nReplacement\nAC (kw):\n8\nSeer:\n15.6\nTons:\n3\nPRODUCT INFORMATION\nCondenser/Air Handler:\nAir Handler\nManufacturer:\nLennox\nModel:\nCBA27uh036230\nCondenser/Air Handler:\nCondenser\nManufacturer:\nLennox\nModel:\nml17xc1036230a01\nParcel Information\nParcel Number:14452447000000412\n*\nBlock:00000\nLot:0412\nSubdivision:24451447\nFLOODINSURANCE2: X (shaded)\nFOLIO: 10463019\nOWNER NAME: LONERGAN MICHELLE B TR\nPLUC1: CO\nUPDATED: 01/02/2021\nUPDATEDBY: PA\nPLANNINGCOMMUNITY: South Fort Myers\nMUNICODE: Lee County Unincorporated\nVACIMP: Improved\nGARBAGEDISTRICT: 003\nFUTURELANDUSE: Intensive Development\nTAXCODE: OFFICE, ONE STORY\nFLOODINSURANCE: X\nCONFIDENTIAL: N\nYEARSPLIT: Jun\nCREATEDATE: 06/06/2001\nBUILDINGYEAR: 1998\nNUMBERUNITS: 1\nSTORMSURGE: B\nBUILDING: 47781\nASSESSED: 41062\nBUILDINGXF: 0\nDEPTH: 0\nLAND: 0\nFRONT: 0\nFLOODWAY: N\nHISTORIC: N\nCOASTALBARRIER: N\nCOASTALBUILDING: N\nCOASTALHIGHHAZARD: N\nSEATURTLE: N\nVEGPERMIT: N\nEAGLENESTING: N\nHOMESTEAD: N\nENFORCEMENTDISTRICT: 58\nF",
      "job_value": "8000",
      "licensed_professional": {
        "city": "FORT MYERS",
        "city_state_zip": "FORT MYERS, FL, 33901",
        "company": "WILLIAM R TAYLOR",
        "license_holder": "2760 BRAMAN AVE UNIT 2",
        "license_notes": "Certified Air Cond Contractor  CAC048106",
        "phones": {
          "primary_phone": "2392260202"
        },
        "postal_code": "33901",
        "state": "FL",
        "street_address": "CALOOSA COOLING LEE COUNTY LLC"
      },
      "licensed_professional_raw": "WILLIAM R TAYLOR | CALOOSA COOLING LEE COUNTY LLC | 2760 BRAMAN AVE UNIT 2 | FORT MYERS, FL, 33901 | Primary Phone: 2392260202 | Certified Air Cond Contractor  CAC048106",
      "owner": "",
      "pcn": "14452447000000412",
      "value_label": "Valuation"
    },
    "grid_cells": [
      "",
      "MEC2023-05376",
      "12510 WORLD PLAZA LN, 2, FORT MYERS FL 33907",
      "replacing existing hvac equipment with 3 ton 15.60 system",
      "Permit Expired",
      "",
      "0",
      "ePlan",
      "12510 WORLD PLAZA LN, 2, FORT MYERS FL 33907"
    ],
    "grid_inferred": {
      "application_date": null,
      "description": "replacing existing hvac equipment with 3 ton 15.60 system",
      "record_type": "replacing existing hvac equipment with 3 ton 15.60 system",
      "site_address": "12510 WORLD PLAZA LN, 2, FORT MYERS FL 33907",
      "status": "Permit Expired"
    },
    "search_window": {
      "end": "07/07/2023",
      "start": "07/07/2023"
    },
    "work_category": "hvac",
    "work_date_basis": "accela_search_window_fallback"
  },
  "source_record_id": "MEC2023-05376",
  "source_url": "https://aca-prod.accela.com/LEECO/Cap/CapDetail.aspx?Module=Permitting&TabName=Permitting&capID1=23CAP&capID2=00000&capID3=01SFO&agencyCode=LEECO&IsToShowInspection=",
  "state": "FL",
  "status": "Permit Expired",
  "work_date": "2023-07-07",
  "work_event_id": "MEC2023-05376",
  "work_type": "replacing existing hvac equipment with 3 ton 15.60 system",
  "work_value": 8000,
  "work_value_source": "Lee Accela Valuation"
}
Get this page with API

Rendered from the bluedoor Licensed Contractors API. Reproduce it:

GET https://api.bluedoor.sh/licensed-contractors/v1/work-events/event_985e635c379dd1d1b34d?include_source_fields=trueJSON
replacing existing hvac equipment with 3 ton 15.60 system — Licensed Contractors data | bluedoor