Electrical event dated 2026-04-23.

Work event

Work event PKevent_85911b522138ae28bbb1
Work typeResidential Electrical Scope / Electrical Scope
Work categoryElectrical
Description- Replace existing 200 amp meter combo with a 400 amp meter base and re feed the existing transfer switch panel - new Metermain combo which will power the nonessential circuits from the interior panel - Run 2 20a 120v dedicated circuits for each outdoor outlet on the back patio (currently being fed from the back room. We will cap off or delete the existing wires. Will run the 2 circuits from the new outdoor panel and down the wall in conduit to a 2 gang bell box where you can split off for each outlet as there is not much space to run conduit down the wall in the back patio) - install Dual Function AFCI/GFCI 20 amp SQ D Homeline breakers for the new circuits - run a jumper from the outlet on the back of the island to the new pop-up outlet that will go on the counter next to the sink. Homeowner will be having someone cut the hole for the outlet and customer will be providing the pop-up outlet - install a new grounding system with a #2 copper to the new meter combo -install surge protection
Work date2026-04-23
StatusComplete
Source record ID26780
JurisdictionMarion County EnerGov Building jurisdiction

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_85911b522138ae28bbb1
Firm IDfirm_35777daadb2b158b353a
Local Identity IDidentity_9cae4b2602a8d0163c96
Portal Keymarion_energov
Jurisdiction ScopeMarion County EnerGov Building jurisdiction
Source Record ID26780
Work Event IDBLDR-26-04-11312
Work TypeResidential Electrical Scope / Electrical Scope
Work Categoryelectrical
Description- Replace existing 200 amp meter combo with a 400 amp meter base and re feed the existing transfer switch panel - new Metermain combo which will power the nonessential circuits from the interior panel - Run 2 20a 120v dedicated circuits for each outdoor outlet on the back patio (currently being fed from the back room. We will cap off or delete the existing wires. Will run the 2 circuits from the new outdoor panel and down the wall in conduit to a 2 gang bell box where you can split off for each outlet as there is not much space to run conduit down the wall in the back patio) - install Dual Function AFCI/GFCI 20 amp SQ D Homeline breakers for the new circuits - run a jumper from the outlet on the back of the island to the new pop-up outlet that will go on the counter next to the sink. Homeowner will be having someone cut the hole for the outlet and customer will be providing the pop-up outlet - install a new grounding system with a #2 copper to the new meter combo -install surge protection
Observed Project Value9,944
Value Typevaluation
Value SourceMarion EnerGov ValuationValue
Value Confidencehigh
Work Date2026-04-23
StatusComplete
Site Address8893 SW 81ST LOOP OCALA
CityOCALA
StateFL
Postal Code-
CountyMarion
Parcel ID3531-0200-26
Latitude-
Longitude-
Source URLhttps://selfservice.marionfl.org/energov_prod/selfservice/api/energov/permits/permit/46...
Raw Payload Pathartifacts/business-backfills/marion_energov/run_date=2026-06-03/kw-all_dates-2026-04-18..2026-04-24_field-issue_pages-1-10_size-100_sm-2_fm-2_details-all.json.gz
Imported At2026-06-03
Source Fields
{
  "business_display_name": "FRANK GAY SERVICES",
  "city": "OCALA",
  "confidence_notes": "Live EnerGov keyword search import; value and contacts parsed from public full-permit model.",
  "county": "Marion",
  "description": "- Replace existing 200 amp meter combo with a 400 amp meter base and re feed the existing transfer switch panel\n- new Metermain combo which will power the nonessential circuits from the interior panel \n- Run 2 20a 120v dedicated circuits for each outdoor outlet on the back patio (currently being fed from the back room. We will cap off or delete the existing wires. Will run the 2 circuits from the new outdoor panel and down the wall in conduit to a 2 gang bell box where you can split off for each outlet as there is not much space to run conduit down the wall in the back patio)\n- install Dual Function AFCI/GFCI 20 amp SQ D Homeline breakers for the new circuits\n- run a jumper from the outlet on the back of the island to the new pop-up outlet that will go on the counter next to the sink. Homeowner will be having someone cut the hole for the outlet and customer will be providing the pop-up outlet\n- install a new grounding system with a #2 copper to the new meter combo\n-install surge protection",
  "email": "[email protected]",
  "insurance_or_bond_summary": null,
  "jurisdiction_scope": "Marion County EnerGov Building jurisdiction",
  "legal_or_dba_name": "FRANK GAY SERVICES",
  "license_number": null,
  "license_status": "active",
  "license_type": "Contractor",
  "mailing_or_firm_address": "PO BOX 60665 \r\nJACKSONVILLE, FL 32236-0665",
  "parcel_id": "3531-0200-26",
  "phone": "(904)591-9269",
  "portal_key": "marion_energov",
  "postal_code": null,
  "qualifier_name": "ROBERT SALLETTE",
  "raw_payload_path": "artifacts/business-backfills/marion_energov/run_date=2026-06-03/kw-all_dates-2026-04-18..2026-04-24_field-issue_pages-1-10_size-100_sm-2_fm-2_details-all.json",
  "scope_layer": "county_permitting_authority",
  "site_address": "8893 SW 81ST LOOP OCALA",
  "source_fields": {
    "attachments_total": 11,
    "contact": {
      "ClientId": null,
      "ContactNumber": "26780",
      "ContactPreferenceId": 6,
      "ContactTypeID": "0A5D5D44-8BBC-4343-BBED-6A58BB673BC2",
      "ContactTypeName": "Contractor",
      "EmailTo": "[email protected]",
      "FirstName": "ROBERT",
      "GlobalEntityID": "7BA70EF4-8299-461D-B79F-7824C0FA65D8",
      "GlobalEntityName": "FRANK GAY SERVICES",
      "IsActive": true,
      "IsBilling": false,
      "IsDeleted": false,
      "IsNew": false,
      "IsPendingConfirmation": false,
      "LastName": "SALLETTE",
      "MainAddress": "PO BOX 60665 \r\nJACKSONVILLE, FL 32236-0665",
      "OtherEmail": "",
      "ParentContactID": "c8eea9a7-4e62-4fea-a112-e0f43a7d2a9d",
      "ParentID": "4650ca74-9b09-4e58-9f86-a2ba6ebe6e73",
      "Phone": "(904)591-9269",
      "PhoneType": "Mobile Phone",
      "Title": ""
    },
    "contacts_total": 5,
    "date_field": "issue",
    "search_row": {
      "Address": {
        "ATTN": "",
        "AddressLine1": "8893",
        "AddressLine2": "SW 81ST LOOP",
        "AddressLine3": "",
        "AddressTypeName": "Location",
        "City": "OCALA",
        "CompSite": "",
        "CountryName": null,
        "CountryTypeId": 0,
        "CountryTypeName": "US",
        "FullAddress": "8893 SW 81ST LOOP OCALA",
        "IsMain": true,
        "POBox": "",
        "PostDirection": "",
        "PostalCode": "",
        "PreDirection": "",
        "ProvinceName": "",
        "RuralRoute": "",
        "StateName": "",
        "Station": "",
        "StreetTypeName": "",
        "UnitOrSuite": ""
      },
      "AddressDisplay": "8893 SW 81ST LOOP OCALA",
      "ApplyDate": "2026-04-13T13:14:33.91",
      "BusinessId": null,
      "BusinessStatus": null,
      "BusinessTypeName": null,
      "CaseId": "4650ca74-9b09-4e58-9f86-a2ba6ebe6e73",
      "CaseNumber": "BLDR-26-04-11312",
      "CaseStatus": "Complete",
      "CaseStatusId": "a99088bd-b9ae-4f5e-b7cd-995dcfb12ac3",
      "CaseType": "Residential Electrical Scope",
      "CaseTypeId": "d69c5ca6-243f-4b65-9179-f7cc54f6b384",
      "CaseWorkclass": "Electrical Scope",
      "CaseWorkclassId": "ebbb43b6-49a3-a79b-82f0-ffcb77b5cc17",
      "ClosedDate": null,
      "CompanyName": null,
      "CompanyTypeName": null,
      "CompleteDate": null,
      "DBA": null,
      "Description": "",
      "ExpectedEndDate": null,
      "ExpireDate": "2026-11-17T14:56:15",
      "FinalDate": "2026-05-22T00:00:00",
      "Highlights": null,
      "HolderCompanyName": null,
      "HolderFirstName": null,
      "HolderLastName": null,
      "HolderMiddleName": null,
      "IssueDate": "2026-04-23T00:00:00",
      "LastAuditDate": null,
      "LicenseYear": null,
      "MainParcel": "3531-0200-26",
      "ModuleName": 2,
      "OpenedDate": null,
      "ProjectName": "CANDLER HILLS WEST LARKHILL SUBDIVISION",
      "RequestDate": null,
      "ScheduleDate": null,
      "StartDate": null,
      "TaxID": null
    },
    "square_feet": 0,
    "work_date_basis": "IssueDate"
  },
  "source_record_id": "26780",
  "source_url": "https://selfservice.marionfl.org/energov_prod/selfservice/api/energov/permits/permit/4650ca74-9b09-4e58-9f86-a2ba6ebe6e73",
  "state": "FL",
  "status": "Complete",
  "work_date": "2026-04-23",
  "work_event_id": "BLDR-26-04-11312",
  "work_type": "Residential Electrical Scope / Electrical Scope",
  "work_value": 9944,
  "work_value_source": "Marion EnerGov ValuationValue"
}
Get this page with API

Rendered from the bluedoor Licensed Contractors API. Reproduce it:

GET https://api.bluedoor.sh/licensed-contractors/v1/work-events/event_85911b522138ae28bbb1?include_source_fields=trueJSON
- Replace existing 200 amp meter combo with a 400 amp meter base an... — Licensed Contractors data | bluedoor