Source Fields
{
"business_display_name": "KENNETH GRIMES",
"city": null,
"confidence_notes": "Live Accela date-window import; value and contractor parsed from public CapDetail page.",
"county": "Lee",
"description": "install devices to existing fire alarm system;\r\n*R01 - updated drawing to show no exit door in training (127) and in conference (120), so removed pull stations. Relocated FACP and added a smoke above the panel. Updated drawing to show fire suppression monitor modules. Relocated pull stations (01-158-01-160 &01-163) updated the battery calculations*",
"email": null,
"insurance_or_bond_summary": null,
"jurisdiction_scope": "Lee County Accela Permitting jurisdiction",
"legal_or_dba_name": "KENNETH GRIMES",
"license_number": "EC13009064",
"license_status": null,
"license_type": "Certified Electrical Contractor EC13009064",
"mailing_or_firm_address": "ALL DIGITAL TECHNOLOGY FORT MYERS FL 33966",
"parcel_id": "16452724000250010",
"phone": null,
"portal_key": "lee_accela",
"postal_code": null,
"qualifier_name": "11000 METRO PARKWAY",
"raw_payload_path": "artifacts/business-backfills/lee_accela/run_date=2026-06-04/08-16-2023_08-16-2023_type-all_pages-50_details-all.json",
"scope_layer": "county_permitting_authority",
"site_address": "600 HOMESTEAD RD S, LEHIGH ACRES FL 33974",
"source_fields": {
"detail": {
"detail_text_sample": "Accela Citizen Access\nLogin\n|\nRegister for an Account\n|\nAnnouncements\n(\n)\n|\nMark as Read\nTip:\nThe Global Search can be used for quick searches, using a case number, address, strap number (no special characters), or license number.\nNew Record Creation & Document Uploading:\nReport Issues, Ask Questions, Provide Feedback, or Request Training\nhere\n. For more information about uploading documents using our new Digital Projects feature, click\nhere\n.\nCredit Card & Payment Info:\nLee County Government staff will never call you and ask for credit card or other sensitive information. Please report all fraudulent activity to the Lee County Sheriff's Office Fraud Unit at 239-258-3292.\nmore\nmore\nMessage Bar\nRecord\nFIR2023-01874\n:\nCommercial Fire Permit\nRecord Status:\nClosed-CC Issued\nClick here for more information\nCreate a New Collection\n*\nName:\nDescription:\nspell check\nAdd\nCancel\nRecord Info\nRecord Details\nProcessing Status\nRelated Records\nInspections\nPayments\nFees\nConditions\nWork Location\n600 602 HOMESTEAD RD S\nLEHIGH ACRES FL 33974\n*\nRecord Details\nIMPORTANT NOTE:\nFor Record Dates (i.e. Received Date, Issued Date, Expiration Date and Finaled Date) or Certificates of Occupancy, Compliance & Use, click Reports at the top of the page, and select the appropriate report name. Certificates of Occupancy, Compliance & Use are only available for records in Closed-CO Issued, Closed-CC Issued, and Closed-Cert of Use Issued, record status.\nApplicant:\nChris\nHorn\nGulf Life Permitting\n15700 red fox run\nFort Myers,\nFL,\n33912\nPrimary Phone:\n2397707524\nCell Phone:\n2397707524\[email protected]\nLicensed Professional:\nKENNETH GRIMES\nALL DIGITAL TECHNOLOGY\n11000 METRO PARKWAY\nFORT MYERS, FL, 33966\nPrimary Phone:\n2392784111\nCertified Electrical Contractor EC13009064\nProject Description:\nLee County Supervisor Of Elections FA\ninstall devices to existing fire alarm system;\n*R01 - updated drawing to show no exit door in training (127) and in conference (120), so removed pull stations. Relocated FACP and added a smoke above the panel. Updated drawing to show fire suppression monitor modules. Relocated pull stations (01-158-01-160 &01-163) updated the battery calculations*\nMore Details\nApplication Information\nOWNER BUILDER\nIs the permit being pulled as Owner-Builder?:\nNo\nDISASTER RECOVERY INFO\nIs the proposed work a result of hurricane damage?:\nNo\nGENERAL INFORMATION\nType of Permit:\nFire Alarms\nAction Type:\nRepair/Replace\nJob Value:\n22975\nAdditional Building Information:\nExisting Building\nOccupancy Type:\ncommercial\nFire Alarm:\nYes\nNumber of Devices:\n21\nMonitoring System:\nNo\nCommunicator:\nNo\nPrivate Provider Plan Review?:\nNo\nPrivate Provider Inspections?:\nNo\nDo any additional Addresses or Unit/Suite Numbers need to be added to the record?:\nNo\nIs the Address on the record correct and complete?:\nYes\nDirections:\nFA at 600 homestead rd\nI hereby certify that my license qualifies me to perform the improvements proposed herein, in accordance with the applicable sections of the Florida Statutes, including F.S. 489, or Executive/Legislative Order currently in effect.:\nYes\nParcel Information\nParcel Number:16452724000250010\n*\nBlock:00025\nLot:0010\nSubdivision:--\nCOMMUNITYPLANNINGAREA: Lehigh Acres\nFOLIO: 10552683\nOWNER NAME: LEE COUNTY\nPLUC1: CP\nPLUC2: VA\nUPDATED: 06/02/2022\nUPDATEDBY: PA\nPLANNINGCOMMUNITY: Lehigh Acres\nMUNICODE: Lee County Unincorporated\nMODEL: commercial\nVACIMP: Improved\nGARBAGEDISTRICT: 004\nFUTURELANDUSE: Urban Community\nTAXCODE: COUNTIES - OTHER\nFLOODINSURANCE: X\nCONFIDENTIAL: N\nYEARSPLIT: Apr\nCREATEDATE: 04/17/2009\nBUILDINGYEAR: 2019\nNUMBERUNITS: 172236\nSTORMSURGE: E\nBUILDING: 1676719\nASSESSED: 2333824\nBUILDINGXF: 73951\nDEPTH: 0\nLAND: 657105\nFRONT: 0\nFLOODWAY: N\nHISTORIC: N\nCOASTALBARRIER: N\nCOASTALBUILDING: N\nCOASTALHIGHHAZARD: N\nSEATURTLE: N\nVEGPERMIT: N\nEAGLENESTING: N\nHOMESTEAD: N\nENFORCEMENTDISTRICT: 38\nFIREDISTRICT: Lehigh Acres\nPREVSTRAP: 16452724000250000\nPREVFOLIO: 10418175\nSTORIES: 1.0\nBATHROOMS: 0.0\nBEDROOMS: 0\nSOIL1: POMPANO FINE SAND, D",
"job_value": "22975",
"licensed_professional": {
"city": "FORT MYERS",
"city_state_zip": "FORT MYERS, FL, 33966",
"company": "KENNETH GRIMES",
"license_holder": "11000 METRO PARKWAY",
"license_notes": "Certified Electrical Contractor EC13009064",
"phones": {
"primary_phone": "2392784111"
},
"postal_code": "33966",
"state": "FL",
"street_address": "ALL DIGITAL TECHNOLOGY"
},
"licensed_professional_raw": "KENNETH GRIMES | ALL DIGITAL TECHNOLOGY | 11000 METRO PARKWAY | FORT MYERS, FL, 33966 | Primary Phone: 2392784111 | Certified Electrical Contractor EC13009064",
"owner": "",
"pcn": "16452724000250010",
"value_label": "Job Value"
},
"grid_cells": [
"",
"FIR2023-01874",
"600 HOMESTEAD RD S, LEHIGH ACRES FL 33974",
"install devices to existing fire alarm system;\r\n*R01 - updated drawing to show no exit door in training (127) and in conference (120), so removed pull stations. Relocated FACP and added a smoke above the panel. Updated drawing to show fire suppression monitor modules. Relocated pull stations (01-158-01-160 &01-163) updated the battery calculations*",
"Closed-CC Issued",
"",
"6",
"ePlan",
"600 HOMESTEAD RD S, LEHIGH ACRES FL 33974"
],
"grid_inferred": {
"application_date": null,
"description": "install devices to existing fire alarm system;\r\n*R01 - updated drawing to show no exit door in training (127) and in conference (120), so removed pull stations. Relocated FACP and added a smoke above the panel. Updated drawing to show fire suppression monitor modules. Relocated pull stations (01-158-01-160 &01-163) updated the battery calculations*",
"record_type": "install devices to existing fire alarm system;\r\n*R01 - updated drawing to show no exit door in training (127) and in conference (120), so removed pull stations. Relocated FACP and added a smoke above the panel. Updated drawing to show fire suppression monitor modules. Relocated pull stations (01-158-01-160 &01-163) updated the battery calculations*",
"site_address": "600 HOMESTEAD RD S, LEHIGH ACRES FL 33974",
"status": "Closed-CC Issued"
},
"search_window": {
"end": "08/16/2023",
"start": "08/16/2023"
},
"work_category": "windows_doors",
"work_date_basis": "accela_search_window_fallback"
},
"source_record_id": "FIR2023-01874",
"source_url": "https://aca-prod.accela.com/LEECO/Cap/CapDetail.aspx?Module=Permitting&TabName=Permitting&capID1=23CAP&capID2=00000&capID3=023UR&agencyCode=LEECO&IsToShowInspection=",
"state": "FL",
"status": "Closed-CC Issued",
"work_date": "2023-08-16",
"work_event_id": "FIR2023-01874",
"work_type": "install devices to existing fire alarm system;\r\n*R01 - updated drawing to show no exit door in training (127) and in conference (120), so removed pull stations. Relocated FACP and added a smoke above the panel. Updated drawing to show fire suppression monitor modules. Relocated pull stations (01-158-01-160 &01-163) updated the battery calculations*",
"work_value": 22975,
"work_value_source": "Lee Accela Job Value"
}