Source Fields
{
"business_display_name": "MICHAEL K HAMMERSLEY SR",
"city": null,
"confidence_notes": "Live Accela date-window import; value and contractor parsed from public CapDetail page.",
"county": "Lee",
"description": "ac changeout",
"email": null,
"insurance_or_bond_summary": null,
"jurisdiction_scope": "Lee County Accela Permitting jurisdiction",
"legal_or_dba_name": "MICHAEL K HAMMERSLEY SR",
"license_number": "CAC1817144",
"license_status": null,
"license_type": "Certified Air Cond Contractor CAC1817144",
"mailing_or_firm_address": "BUCKEYE HEATING AND COOLING LLC FORT MYERS FL 33967",
"parcel_id": "09462408000120150",
"phone": null,
"portal_key": "lee_accela",
"postal_code": null,
"qualifier_name": "18493 BRADENTON RD",
"raw_payload_path": "artifacts/business-backfills/lee_accela/run_date=2026-06-04/08-30-2023_08-30-2023_type-all_pages-50_details-all.json",
"scope_layer": "county_permitting_authority",
"site_address": "16448 EDGEMONT DR, FORT MYERS FL 33908",
"source_fields": {
"detail": {
"detail_text_sample": "Accela Citizen Access\nLogin\n|\nRegister for an Account\n|\nAnnouncements\n(\n)\n|\nMark as Read\nTip:\nThe Global Search can be used for quick searches, using a case number, address, strap number (no special characters), or license number.\nNew Record Creation & Document Uploading:\nReport Issues, Ask Questions, Provide Feedback, or Request Training\nhere\n. For more information about uploading documents using our new Digital Projects feature, click\nhere\n.\nCredit Card & Payment Info:\nLee County Government staff will never call you and ask for credit card or other sensitive information. Please report all fraudulent activity to the Lee County Sheriff's Office Fraud Unit at 239-258-3292.\nmore\nmore\nMessage Bar\nRecord\nMEC2023-06763\n:\nMechanical\nRecord Status:\nClosed-CC Issued\nCreate a New Collection\n*\nName:\nDescription:\nspell check\nAdd\nCancel\nRecord Info\nRecord Details\nProcessing Status\nRelated Records\nInspections\nPayments\nFees\nConditions\nWork Location\n16448 EDGEMONT DR\nFORT MYERS FL 33908\n*\nRecord Details\nIMPORTANT NOTE:\nFor Record Dates (i.e. Received Date, Issued Date, Expiration Date and Finaled Date) or Certificates of Occupancy, Compliance & Use, click Reports at the top of the page, and select the appropriate report name. Certificates of Occupancy, Compliance & Use are only available for records in Closed-CO Issued, Closed-CC Issued, and Closed-Cert of Use Issued, record status.\nApplicant:\nMICHAEL\nHAMMERSLEY SR\n201308270911425960\nBUCKEYE HEATING AND COOLING LLC\n18493 BRADENTON RD\nFORT MYERS,\nFL,\n33967\nPrimary Phone:\n2396538070\[email protected]\nLicensed Professional:\nMICHAEL K HAMMERSLEY SR\nBUCKEYE HEATING AND COOLING LLC\n18493 BRADENTON RD\nFORT MYERS, FL, 33967\nPrimary Phone:\n2396538070\nCertified Air Cond Contractor CAC1817144\nProject Description:\nLexington Country Club\nac changeout\nMore Details\nApplication Information\nOWNER BUILDER\nIs the permit being pulled as Owner-Builder?:\nNo\nDISASTER RECOVERY INFO\nIs the proposed work a result of hurricane damage?:\nNo\nGENERAL INFORMATION\nType of Permit:\nSplit System\nCommercial/Residential:\nResidential\nValuation:\n7798.00\nNew/Replace/Other:\nReplacement\nPrivate Provider Plan Review?:\nNo\nPrivate Provider Inspections?:\nNo\nDirections:\nLexington Country Club\nApplication Information Table\nAC DETAILS\nType of System:\nSplit System\nAction:\nReplacement\nConditioned Area (SqFt):\n1842\nAC (kw):\n10\nSeer:\n15.2\nTons:\n3.5\nPRODUCT INFORMATION\nCondenser/Air Handler:\nAir Handler\nManufacturer:\nDay + Night\nModel:\nFJM4X42\nCondenser/Air Handler:\nCondenser\nManufacturer:\nDay + Night\nModel:\nN4A5S42\nParcel Information\nParcel Number:09462408000120150\n*\nBlock:00012\nLot:0150\nSubdivision:--\nFOLIO: 10437327\nOWNER NAME: CARROLL WILLIAM Y & CLARA C\nPLUC1: RS\nPLUC2: PG\nPLUC3: PR\nUPDATED: 01/02/2023\nUPDATEDBY: PA\nPLANNINGCOMMUNITY: Iona/McGregor\nMUNICODE: Lee County Unincorporated\nMODEL: single family residential\nVACIMP: Improved\nGARBAGEDISTRICT: 002\nFUTURELANDUSE: Outlying Suburban\nTAXCODE: SINGLE FAMILY RESIDENTIAL\nFLOODINSURANCE: AE\nCONFIDENTIAL: N\nCREATEDATE: 04/03/1997\nBUILDINGYEAR: 1998\nNUMBERUNITS: 1\nSTORMSURGE: B\nBUILDING: 366709\nASSESSED: 429227\nBUILDINGXF: 28762\nDEPTH: 0\nLAND: 113700\nFRONT: 0\nFLOODWAY: N\nHISTORIC: N\nCOASTALBARRIER: N\nCOASTALBUILDING: N\nCOASTALHIGHHAZARD: Y\nSEATURTLE: N\nVEGPERMIT: N\nEAGLENESTING: N\nHOMESTEAD: Y\nENFORCEMENTDISTRICT: 60\nFIREDISTRICT: Iona-McGregor\nPREVSTRAP: 09462405000120000\nPREVFOLIO: 10224992\nSTORIES: 1.0\nBATHROOMS: 2.0\nBEDROOMS: 3\nSOIL1: IMMOKALEE SAND\nZONING1: RPD\nWSBLDGRISKI: 150 mph\nWSBLDGRISKII: 160 mph\nWSBLDGRISKIIIIV: 180 mph\nSALEDATE: 07/11/2022\nAMOUNT: 730000\nSALEINSTRUMENT: 2022000234348\nSALEDATE2: 03/06/2007\nSALEAMOUNT2: 540000\nSALEINSTRUMENT2: 2007000076009\nSALEDATE3: 10/31/2003\nSALEAMOUNT3: 345000\nSALEBOOK3: B4121\nSALEPAGE3: P3067\nFees\n*Fee Reductions are calculated at 25% of the Fee Amount, and exclude certain fee types (i.e. Impact Fees, Solid Waste Fees, etc.)\nEffective Date - 12/1/2020; End Date - 11/30/2022\nLearn how to view your discounts\nLoading...\nInspections\nIMPO",
"job_value": "7798.00",
"licensed_professional": {
"city": "FORT MYERS",
"city_state_zip": "FORT MYERS, FL, 33967",
"company": "MICHAEL K HAMMERSLEY SR",
"license_holder": "18493 BRADENTON RD",
"license_notes": "Certified Air Cond Contractor CAC1817144",
"phones": {
"primary_phone": "2396538070"
},
"postal_code": "33967",
"state": "FL",
"street_address": "BUCKEYE HEATING AND COOLING LLC"
},
"licensed_professional_raw": "MICHAEL K HAMMERSLEY SR | BUCKEYE HEATING AND COOLING LLC | 18493 BRADENTON RD | FORT MYERS, FL, 33967 | Primary Phone: 2396538070 | Certified Air Cond Contractor CAC1817144",
"owner": "",
"pcn": "09462408000120150",
"value_label": "Valuation"
},
"grid_cells": [
"",
"MEC2023-06763",
"16448 EDGEMONT DR, FORT MYERS FL 33908",
"ac changeout",
"Closed-CC Issued",
"",
"0",
"ePlan",
"16448 EDGEMONT DR, FORT MYERS FL 33908"
],
"grid_inferred": {
"application_date": null,
"description": "ac changeout",
"record_type": "ac changeout",
"site_address": "16448 EDGEMONT DR, FORT MYERS FL 33908",
"status": "Closed-CC Issued"
},
"search_window": {
"end": "08/30/2023",
"start": "08/30/2023"
},
"work_category": "hvac",
"work_date_basis": "accela_search_window_fallback"
},
"source_record_id": "MEC2023-06763",
"source_url": "https://aca-prod.accela.com/LEECO/Cap/CapDetail.aspx?Module=Permitting&TabName=Permitting&capID1=23CAP&capID2=00000&capID3=027Q6&agencyCode=LEECO&IsToShowInspection=",
"state": "FL",
"status": "Closed-CC Issued",
"work_date": "2023-08-30",
"work_event_id": "MEC2023-06763",
"work_type": "ac changeout",
"work_value": 7798,
"work_value_source": "Lee Accela Valuation"
}