Hvac event dated 2024-08-29.

Work event

Work event PKevent_6dab14d2e83fa8a9e2a5
Work typeMechanical Permit
Work categoryHvac
DescriptionQuick Permit - Demolition as per plan Page M-100,Furnish and install temperature controls – Update existing Alerton DDC System (BAS) for control and monitoring of the scope below. System interface to be web based with user access via any standard internet browser. Furnish and install two (2) ductless cassette mini split system with wall mounted thermostat wired for standalone control Furnish and Install six (6) six VAV Terminal Units. Furnish and install Air Distribution diffusers and grills Furnish and install chilled water piping system. Refrigerant piping. Condensate Drain Piping (Schedule 40 PVC) All Ducts to be G90 Galvanized Sheet Metal and constructed to SMACNA duct construction-ASTM. w/external seams sealed for vapor barrier Round medium-pressure ductwork quoted as single wall galvanized spiral pipe and snaplock metal galvanized pipe for low-pressure ductwork after the VAV’s boxes Ductwrap insulation for ductwork "Additionally, work will be done to tie in new chilled water lines into existing system from roof into tenant space and leave with 2 ball valves for future use” Lifting and hoisting required for HVAC work 21.3 SEERS 5 TONS Manufacturer: Mitsubishi
Work date2024-08-29
StatusFinal
Source record IDA24-007594
JurisdictionOsceola County Citizen Access Building module

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_6dab14d2e83fa8a9e2a5
Firm IDfirm_3f11433b37da87e5ad30
Local Identity IDidentity_00ae924653fadef295b3
Portal Keyosceola_accela_building
Jurisdiction ScopeOsceola County Citizen Access Building module
Source Record IDA24-007594
Work Event IDA24-007594
Work TypeMechanical Permit
Work Categoryhvac
DescriptionQuick Permit - Demolition as per plan Page M-100,Furnish and install temperature controls – Update existing Alerton DDC System (BAS) for control and monitoring of the scope below. System interface to be web based with user access via any standard internet browser. Furnish and install two (2) ductless cassette mini split system with wall mounted thermostat wired for standalone control Furnish and Install six (6) six VAV Terminal Units. Furnish and install Air Distribution diffusers and grills Furnish and install chilled water piping system. Refrigerant piping. Condensate Drain Piping (Schedule 40 PVC) All Ducts to be G90 Galvanized Sheet Metal and constructed to SMACNA duct construction-ASTM. w/external seams sealed for vapor barrier Round medium-pressure ductwork quoted as single wall galvanized spiral pipe and snaplock metal galvanized pipe for low-pressure ductwork after the VAV’s boxes Ductwrap insulation for ductwork "Additionally, work will be done to tie in new chilled water lines into existing system from roof into tenant space and leave with 2 ball valves for future use” Lifting and hoisting required for HVAC work 21.3 SEERS 5 TONS Manufacturer: Mitsubishi
Observed Project Value179,315
Value Typejob_value
Value SourceOsceola County Accela Citizen Access Building Applicant Job Value
Value Confidencehigh
Work Date2024-08-29
StatusFinal
Site Address194 NEOCITY WY, KISSIMMEE FL 34744
City-
StateFL
Postal Code-
CountyOsceola
Parcel ID242529332300010030
Latitude-
Longitude-
Source URLhttps://permits.osceola.org/CitizenAccess/Cap/CapDetail.aspx?Module=Building&TabName=Bu...
Raw Payload Pathartifacts/business-backfills/osceola_accela_building/run_date=2026-06-05/date-2024-08-29_all-permit-types/grid-records.json
Imported At2026-06-05
Source Fields
{
  "business_display_name": "COR3 MECHANICAL, LLC",
  "confidence_notes": "Mapped from Accela Building Search by Record Information plus CapDetail; date window and record type are public search criteria.",
  "contractor_license_number": "CAC1821334",
  "contractor_name": "COR3 MECHANICAL, LLC",
  "county": "Osceola",
  "description": "Quick Permit - Demolition as per plan Page M-100,Furnish and install temperature controls – Update existing Alerton DDC System (BAS) for control and monitoring of the scope below. System interface to be web based with user access via any standard internet browser. Furnish and install two (2) ductless cassette mini split system with wall mounted thermostat wired for standalone control Furnish and Install six (6) six VAV Terminal Units. Furnish and install Air Distribution diffusers and grills Furnish and install chilled water piping system. Refrigerant piping. Condensate Drain Piping (Schedule 40 PVC) All Ducts to be G90 Galvanized Sheet Metal and constructed to SMACNA duct construction-ASTM. w/external seams sealed for vapor barrier Round medium-pressure ductwork quoted as single wall galvanized spiral pipe and snaplock metal galvanized pipe for low-pressure ductwork after the VAV’s boxes Ductwrap insulation for ductwork \"Additionally, work will be done to tie in new chilled water lines into existing system from roof into tenant space and leave with 2 ball valves for future use” Lifting and hoisting required for HVAC work 21.3 SEERS 5 TONS Manufacturer: Mitsubishi",
  "email": "[email protected]",
  "jurisdiction_scope": "Osceola County Citizen Access Building module",
  "legal_or_dba_name": "COR3 MECHANICAL, LLC",
  "license_number": "CAC1821334",
  "license_type": "CLASS A AIR CONDITIONING",
  "mailing_or_firm_address": "2301 Maitland Center Parkway Suite 150 Maitland, FL, 32751",
  "normalized_license_number": "CAC1821334",
  "observed_project_value": "179315",
  "parcel_id": "242529332300010030",
  "phone": "",
  "portal_key": "osceola_accela_building",
  "qualifier_name": "Bobby Wayne Barnhardt",
  "raw_payload_path": "artifacts/business-backfills/osceola_accela_building/run_date=2026-06-05/date-2024-08-29_all-permit-types/grid-records.json",
  "scope_layer": "county_permitting_authority",
  "site_address": "194 NEOCITY WY, KISSIMMEE FL 34744",
  "source_fields": {
    "detail": {
      "description": "COMM-Mechanical Mechanical Permit",
      "job_value": "179315",
      "licensed_professional": {
        "company": "COR3 MECHANICAL, LLC",
        "description": "",
        "email": "[email protected]",
        "license_number": "CAC1821334",
        "license_type": "CLASS A AIR CONDITIONING",
        "mailing_address": "2301 Maitland Center Parkway Suite 150 Maitland, FL, 32751",
        "parts": [
          "Bobby Wayne Barnhardt [email protected]",
          "COR3 MECHANICAL, LLC",
          "2301 Maitland Center Parkway",
          "Suite 150",
          "Maitland, FL, 32751",
          "CLASS A AIR CONDITIONING CAC1821334"
        ],
        "phone": "",
        "qualifier_name": "Bobby Wayne Barnhardt",
        "raw": "Bobby Wayne Barnhardt [email protected] | COR3 MECHANICAL, LLC | 2301 Maitland Center Parkway | Suite 150 | Maitland, FL, 32751 | CLASS A AIR CONDITIONING  CAC1821334"
      },
      "owner": "",
      "pcn": "242529332300010030",
      "record_type": "Mechanical Permit",
      "status": "Final"
    },
    "grid": {
      "cells": [
        "",
        "08/29/2024",
        "A24-007594",
        "Mechanical Permit",
        "COMM-Mechanical Mechanical Permit",
        "194 NEOCITY WY, KISSIMMEE FL 34744",
        "Final",
        "",
        "Quick Permit - Demolition as per plan Page M-100,Furnish and install temperature controls – Update existing Alerton DDC System (BAS) for control and monitoring of the scope below. System interface to be web based with user access via any standard internet browser. Furnish and install two (2) ductless cassette mini split system with wall mounted thermostat wired for standalone control Furnish and Install six (6) six VAV Terminal Units. Furnish and install Air Distribution diffusers and grills Furnish and install chilled water piping system. Refrigerant piping. Condensate Drain Piping (Schedule 40 PVC) All Ducts to be G90 Galvanized Sheet Metal and constructed to SMACNA duct construction-ASTM. w/external seams sealed for vapor barrier Round medium-pressure ductwork quoted as single wall galvanized spiral pipe and snaplock metal galvanized pipe for low-pressure ductwork after the VAV’s boxes Ductwrap insulation for ductwork \"Additionally, work will be done to tie in new chilled water lines into existing system from roof into tenant space and leave with 2 ball valves for future use” Lifting and hoisting required for HVAC work 21.3 SEERS 5 TONS Manufacturer: Mitsubishi",
        "",
        "",
        "194 NEOCITY WY, KISSIMMEE FL 34744"
      ],
      "description": "Quick Permit - Demolition as per plan Page M-100,Furnish and install temperature controls – Update existing Alerton DDC System (BAS) for control and monitoring of the scope below. System interface to be web based with user access via any standard internet browser. Furnish and install two (2) ductless cassette mini split system with wall mounted thermostat wired for standalone control Furnish and Install six (6) six VAV Terminal Units. Furnish and install Air Distribution diffusers and grills Furnish and install chilled water piping system. Refrigerant piping. Condensate Drain Piping (Schedule 40 PVC) All Ducts to be G90 Galvanized Sheet Metal and constructed to SMACNA duct construction-ASTM. w/external seams sealed for vapor barrier Round medium-pressure ductwork quoted as single wall galvanized spiral pipe and snaplock metal galvanized pipe for low-pressure ductwork after the VAV’s boxes Ductwrap insulation for ductwork \"Additionally, work will be done to tie in new chilled water lines into existing system from roof into tenant space and leave with 2 ball valves for future use” Lifting and hoisting required for HVAC work 21.3 SEERS 5 TONS Manufacturer: Mitsubishi",
      "detail": {
        "description": "COMM-Mechanical Mechanical Permit",
        "job_value": "179315",
        "licensed_professional": {
          "company": "COR3 MECHANICAL, LLC",
          "description": "",
          "email": "[email protected]",
          "license_number": "CAC1821334",
          "license_type": "CLASS A AIR CONDITIONING",
          "mailing_address": "2301 Maitland Center Parkway Suite 150 Maitland, FL, 32751",
          "parts": [
            "Bobby Wayne Barnhardt [email protected]",
            "COR3 MECHANICAL, LLC",
            "2301 Maitland Center Parkway",
            "Suite 150",
            "Maitland, FL, 32751",
            "CLASS A AIR CONDITIONING CAC1821334"
          ],
          "phone": "",
          "qualifier_name": "Bobby Wayne Barnhardt",
          "raw": "Bobby Wayne Barnhardt [email protected] | COR3 MECHANICAL, LLC | 2301 Maitland Center Parkway | Suite 150 | Maitland, FL, 32751 | CLASS A AIR CONDITIONING  CAC1821334"
        },
        "owner": "",
        "pcn": "242529332300010030",
        "record_type": "Mechanical Permit",
        "status": "Final"
      },
      "detail_url": "https://permits.osceola.org/CitizenAccess/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=REC24&capID2=00000&capID3=00UU4&agencyCode=OSCEOLA&IsToShowInspection=",
      "headers": [
        "",
        "Date",
        "Record Number",
        "Record Type",
        "Project Name",
        "Address",
        "Status",
        "Action",
        "Description",
        "Expiration Date",
        "Short Notes",
        ""
      ],
      "hidden_record_id": "REC24-00000-00UU4",
      "record_date": "08/29/2024",
      "record_number": "A24-007594",
      "record_type": "Mechanical Permit",
      "site_address": "194 NEOCITY WY, KISSIMMEE FL 34744",
      "status": "Final"
    }
  },
  "source_record_id": "A24-007594",
  "source_url": "https://permits.osceola.org/CitizenAccess/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=REC24&capID2=00000&capID3=00UU4&agencyCode=OSCEOLA&IsToShowInspection=",
  "state": "FL",
  "status": "Final",
  "work_date": "08/29/2024",
  "work_event_id": "A24-007594",
  "work_type": "Mechanical Permit",
  "work_value": "179315",
  "work_value_source": "Osceola County Accela Citizen Access Building Applicant Job Value"
}
Get this page with API

Rendered from the bluedoor Licensed Contractors API. Reproduce it:

GET https://api.bluedoor.sh/licensed-contractors/v1/work-events/event_6dab14d2e83fa8a9e2a5?include_source_fields=trueJSON
Quick Permit - Demolition as per plan Page M-100,Furnish and instal... — Licensed Contractors data | bluedoor