bluedoor data·Licensed Contractors API·bluedoor.sh ↗

HomeWork eventsInstall NFPA 13R wet sprinkler system starting at 1'-0" AFF Building 5

Install NFPA 13R wet sprinkler system starting at 1'-0" AFF Building 5

Commercial Building event dated 2025-06-04.

Work event

Work event PKevent_59695fac76b16a24cabb
Work typeFire Permit (Commercial, New Work)
Work categoryCommercial Building
DescriptionInstall NFPA 13R wet sprinkler system starting at 1'-0" AFF Building 5
Work date2025-06-04
StatusIssued
Source record ID5618237:Fire Sprinkler:20250603048
JurisdictionVolusia Connect Live / AMANDA portal jurisdiction

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_59695fac76b16a24cabb
Firm IDfirm_58159a069ba8f968a613
Local Identity IDidentity_073dc725934aad38b7af
Portal Keyvolusia_amanda
Jurisdiction ScopeVolusia Connect Live / AMANDA portal jurisdiction
Source Record ID5618237:Fire Sprinkler:20250603048
Work Event ID20250603048
Work TypeFire Permit (Commercial, New Work)
Work Categorycommercial_building
DescriptionInstall NFPA 13R wet sprinkler system starting at 1'-0" AFF Building 5
Observed Project Value10,276
Value Typedeclared_value
Value SourceVolusia AMANDA Additional Information Declared Construction Cost
Value Confidencehigh
Work Date2025-06-04
StatusIssued
Site Address2360 OCEAN SHORE Boulevard, ORMOND BEACH 32176
CityORMOND BEACH
StateFL
Postal Code32176
CountyVolusia
Parcel ID322700010020
Latitude-
Longitude-
Source URLhttps://connectlivepermits.org/citizenportal/app/
Raw Payload Pathartifacts/business-layer-samples/volusia_amanda/run_date=2026-06-05/raw/folders_2025-06-01_2025-06-07/folder_details.json
Imported At2026-06-05
Source Fields
{
  "business_display_name": "Wayne Automatic Fire Sprinklers Inc.",
  "city": "ORMOND BEACH",
  "confidence_notes": "Parsed from Volusia AMANDA Open Folders, Record Details, People Details, and Additional Information public endpoints.",
  "county": "Volusia",
  "description": "Install NFPA 13R wet sprinkler system starting at 1'-0\" AFF Building 5",
  "email": "",
  "insurance_or_bond_summary": "",
  "jurisdiction_scope": "Volusia Connect Live / AMANDA portal jurisdiction",
  "legal_or_dba_name": "Wayne Automatic Fire Sprinklers Inc.",
  "license_number": "",
  "license_status": "",
  "license_type": "Fire Sprinkler",
  "mailing_or_firm_address": "Mr. Robert Dewar,Wayne Automatic Fire Sprinklers Inc. 222 Capitol Ct.",
  "parcel_id": "322700010020",
  "phone": "",
  "portal_key": "volusia_amanda",
  "postal_code": "32176",
  "qualifier_name": "Robert Dewar",
  "raw_payload_path": "artifacts/business-layer-samples/volusia_amanda/run_date=2026-06-05/raw/folders_2025-06-01_2025-06-07/folder_details.json",
  "scope_layer": "county_permitting_authority",
  "site_address": "2360 OCEAN SHORE Boulevard, ORMOND BEACH 32176",
  "source_fields": {
    "additional_info": [
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Last Activity Date",
        "name": "50020",
        "options": "",
        "readonly": "Y",
        "title": "Last Activity Date",
        "type": "D",
        "value": "2026-01-12"
      },
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Jurisdiction",
        "name": "50000",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"County\",\"value\":\"County\"},{\"label\":\"Daytona Beach\",\"value\":\"Daytona Beach\"},{\"label\":\"Daytona Beach Shores\",\"value\":\"Daytona Beach Shores\"},{\"label\":\"DeBary\",\"value\":\"DeBary\"},{\"label\":\"DeLand\",\"value\":\"DeLand\"},{\"label\":\"Deltona\",\"value\":\"Deltona\"},{\"label\":\"Edgewater\",\"value\":\"Edgewater\"},{\"label\":\"Flagler Beach\",\"value\":\"Flagler Beach\"},{\"label\":\"Holly Hill\",\"value\":\"Holly Hill\"},{\"label\":\"Lake Helen\",\"value\":\"Lake Helen\"},{\"label\":\"New Smyrna Beach\",\"value\":\"New Smyrna Beach\"},{\"label\":\"Oak Hill\",\"value\":\"Oak Hill\"},{\"label\":\"Orange City\",\"value\":\"Orange City\"},{\"label\":\"Ormond Beach\",\"value\":\"Ormond Beach\"},{\"label\":\"Pierson\",\"value\":\"Pierson\"},{\"label\":\"Ponce Inlet\",\"value\":\"Ponce Inlet\"},{\"label\":\"Port Orange\",\"value\":\"Port Orange\"},{\"label\":\"South Daytona\",\"value\":\"South Daytona\"}]",
        "readonly": "Y",
        "title": "Jurisdiction",
        "type": "C",
        "value": "County"
      },
      {
        "DisplayOrder": "15",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Reviews by",
        "name": "50005",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Affidavit\",\"value\":\"Affidavit\"},{\"label\":\"County\",\"value\":\"County\"},{\"label\":\"Private Provider\",\"value\":\"Private Provider\"}]",
        "readonly": "Y",
        "title": "Reviews by",
        "type": "C",
        "value": "County"
      },
      {
        "DisplayOrder": "20",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Inspections by",
        "name": "50010",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Affidavit\",\"value\":\"Affidavit\"},{\"label\":\"County\",\"value\":\"County\"},{\"label\":\"Private Provider\",\"value\":\"Private Provider\"}]",
        "readonly": "Y",
        "title": "Inspections by",
        "type": "C",
        "value": "County"
      },
      {
        "DisplayOrder": "25",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Active/Expired Building Permits?",
        "name": "50025",
        "options": "",
        "readonly": "Y",
        "title": "Active/Expired Building Permits?",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "30",
        "Mandatory": "Y",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Preferred Method Of Contact",
        "name": "50015",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Email\",\"value\":\"Email\"},{\"label\":\"Fax\",\"value\":\"Fax\"},{\"label\":\"Mail\",\"value\":\"Mail\"},{\"label\":\"Phone\",\"value\":\"Phone\"},{\"label\":\"Web\",\"value\":\"Web\"}]",
        "readonly": "Y",
        "title": "Preferred Method Of Contact",
        "type": "C",
        "value": "Web"
      },
      {
        "DisplayOrder": "35",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Pickup Job Site Copies",
        "name": "50030",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"DeLand\",\"value\":\"DeLand\"},{\"label\":\"Mail\",\"value\":\"Mail\"},{\"label\":\"Web\",\"value\":\"Web\"}]",
        "readonly": "Y",
        "title": "Pickup Job Site Copies",
        "type": "C",
        "value": "Web"
      },
      {
        "DisplayOrder": "50",
        "Mandatory": "Y",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "After the Fact Permit?",
        "name": "50045",
        "options": "",
        "readonly": "Y",
        "title": "After the Fact Permit?",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "55",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Inspections Assigned to",
        "name": "50050",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Brad Deverall\",\"value\":\"Brad Deverall\"},{\"label\":\"Bryan Bradburn\",\"value\":\"Bryan Bradburn\"},{\"label\":\"Clayton Crocker\",\"value\":\"Clayton Crocker\"},{\"label\":\"David Hufstetler\",\"value\":\"David Hufstetler\"},{\"label\":\"David Straight\",\"value\":\"David Straight\"},{\"label\":\"Jay Hamm\",\"value\":\"Jay Hamm\"},{\"label\":\"Kelli Matter\",\"value\":\"Kelli Matter\"},{\"label\":\"Nicholas Ventura\",\"value\":\"Nicholas Ventura\"},{\"label\":\"Richard Dronski\",\"value\":\"Richard Dronski\"},{\"label\":\"Tom Legler\",\"value\":\"Tom Legler\"}]",
        "readonly": "Y",
        "title": "Inspections Assigned to",
        "type": "C",
        "value": ""
      },
      {
        "DisplayOrder": "60",
        "Mandatory": "Y",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Issued Under Building Code",
        "name": "50055",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"2001 Florida Building Code\",\"value\":\"2001 Florida Building Code\"},{\"label\":\"2004 Florida Building Code\",\"value\":\"2004 Florida Building Code\"},{\"label\":\"2007 Florida Building Code\",\"value\":\"2007 Florida Building Code\"},{\"label\":\"2010 Florida Building Code\",\"value\":\"2010 Florida Building Code\"},{\"label\":\"5th Edition Florida Building Code\",\"value\":\"5th Edition Florida Building Code\"},{\"label\":\"6th Edition Florida Building Code\",\"value\":\"6th Edition Florida Building Code\"},{\"label\":\"7th Edition Florida Building Code\",\"value\":\"7th Edition Florida Building Code\"},{\"label\":\"8th Edition Florida Building Code\",\"value\":\"8th Edition Florida Building Code\"},{\"label\":\"HUD Code\",\"value\":\"HUD Code\"}]",
        "readonly": "Y",
        "title": "Issued Under Building Code",
        "type": "C",
        "value": "8th Edition Florida Building Code"
      },
      {
        "DisplayOrder": "65",
        "Mandatory": "Y",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Application Information",
        "groupHelp": "",
        "label": "Natural Disaster Permit",
        "name": "50056",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Debby 2024\",\"value\":\"Debby 2024\"},{\"label\":\"Dec. 2006\",\"value\":\"Dec. 2006\"},{\"label\":\"Dec. 2012 Tornado\",\"value\":\"Dec. 2012 Tornado\"},{\"label\":\"Dorian 2019\",\"value\":\"Dorian 2019\"},{\"label\":\"Feb. 2007\",\"value\":\"Feb. 2007\"},{\"label\":\"Helene 2024\",\"value\":\"Helene 2024\"},{\"label\":\"Ian 2022\",\"value\":\"Ian 2022\"},{\"label\":\"Idalia 2023\",\"value\":\"Idalia 2023\"},{\"label\":\"Irma 2017\",\"value\":\"Irma 2017\"},{\"label\":\"Matthew 2016\",\"value\":\"Matthew 2016\"},{\"label\":\"Milton 2024\",\"value\":\"Milton 2024\"},{\"label\":\"N/A\",\"value\":\"N/A\"},{\"label\":\"Nicole 2022\",\"value\":\"Nicole 2022\"},{\"label\":\"T.S. Faye\",\"value\":\"T.S. Faye\"}]",
        "readonly": "Y",
        "title": "Natural Disaster Permit",
        "type": "C",
        "value": "N/A"
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Work Proposed",
        "groupHelp": "",
        "label": "Non Pre-Engineered Fire Suppression",
        "name": "51635",
        "options": "",
        "readonly": "Y",
        "title": "Non Pre-Engineered Fire Suppression",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Work Proposed",
        "groupHelp": "",
        "label": "Pre-Engineered",
        "name": "51640",
        "options": "",
        "readonly": "Y",
        "title": "Pre-Engineered",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "15",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Work Proposed",
        "groupHelp": "",
        "label": "Sprinklers",
        "name": "51645",
        "options": "",
        "readonly": "Y",
        "title": "Sprinklers",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "16",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Work Proposed",
        "groupHelp": "",
        "label": "Building System (excluding Sprinklers)",
        "name": "51790",
        "options": "",
        "readonly": "Y",
        "title": "Building System (excluding Sprinklers)",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "17",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Work Proposed",
        "groupHelp": "",
        "label": "Fire Tanks",
        "name": "51656",
        "options": "",
        "readonly": "Y",
        "title": "Fire Tanks",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "20",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Work Proposed",
        "groupHelp": "",
        "label": "Alarm",
        "name": "51650",
        "options": "",
        "readonly": "Y",
        "title": "Alarm",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "25",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Work Proposed",
        "groupHelp": "",
        "label": "Fire Underground Lines/Dry Hydrant/Hydrants",
        "name": "51655",
        "options": "",
        "readonly": "Y",
        "title": "Fire Underground Lines/Dry Hydrant/Hydrants",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Electrical Information",
        "groupHelp": "",
        "label": "Electrical work proposed?",
        "name": "50475",
        "options": "",
        "readonly": "Y",
        "title": "Electrical work proposed?",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "35",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "Enter number of electrical circuits being added to the panel",
        "columnClass": "col-md-6",
        "group": "Electrical Information",
        "groupHelp": "",
        "label": "Number of Circuits",
        "name": "51120",
        "options": "",
        "readonly": "Y",
        "title": "Number of Circuits",
        "type": "N",
        "value": ""
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "If the scope of work includes plumbing select the correct water source to expedite the review of your application.\r\nSelecting County initiates a review by Volusia County Utilities. \r\nSelecting Well initiates a Health Dept. inspection on your permit.",
        "columnClass": "col-md-6",
        "group": "Plumbing Information",
        "groupHelp": "",
        "label": "Water Source",
        "name": "51380",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Central\",\"value\":\"Central\"},{\"label\":\"County\",\"value\":\"County\"},{\"label\":\"N/A\",\"value\":\"N/A\"},{\"label\":\"Reclaimed Water\",\"value\":\"Reclaimed Water\"},{\"label\":\"Well\",\"value\":\"Well\"}]",
        "readonly": "Y",
        "title": "Water Source",
        "type": "C",
        "value": ""
      },
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Plumbing Information",
        "groupHelp": "",
        "label": "Water Company",
        "name": "51385",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Astor Utilities\",\"value\":\"Astor Utilities\"},{\"label\":\"Daytona Beach\",\"value\":\"Daytona Beach\"},{\"label\":\"DeLand\",\"value\":\"DeLand\"},{\"label\":\"Deltona\",\"value\":\"Deltona\"},{\"label\":\"Edgewater\",\"value\":\"Edgewater\"},{\"label\":\"Florida Governmental Utility Authority (Flagler Utilities)\",\"value\":\"Florida Governmental Utility Authority (Flagler Utilities)\"},{\"label\":\"Holly Hill\",\"value\":\"Holly Hill\"},{\"label\":\"N/A\",\"value\":\"N/A\"},{\"label\":\"New Smyrna Beach\",\"value\":\"New Smyrna Beach\"},{\"label\":\"North Peninsula Utilities\",\"value\":\"North Peninsula Utilities\"},{\"label\":\"Orange City\",\"value\":\"Orange City\"},{\"label\":\"Ormond Beach\",\"value\":\"Ormond Beach\"},{\"label\":\"Pierson\",\"value\":\"Pierson\"},{\"label\":\"Plantation Bay Utility Co.\",\"value\":\"Plantation Bay Utility Co.\"},{\"label\":\"Port Orange\",\"value\":\"Port Orange\"},{\"label\":\"Village of Pine Run Utility Corp.\",\"value\":\"Village of Pine Run Utility Corp.\"},{\"label\":\"Volusia County\",\"value\":\"Volusia County\"}]",
        "readonly": "Y",
        "title": "Water Company",
        "type": "C",
        "value": ""
      },
      {
        "DisplayOrder": "",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "This does not include residential smoke detectors",
        "columnClass": "col-md-6",
        "group": "Fire Information",
        "groupHelp": "",
        "label": "Fire Alarm Provided?",
        "name": "52105",
        "options": "",
        "readonly": "Y",
        "title": "Fire Alarm Provided?",
        "type": "B",
        "value": "No"
      },
      {
        "DisplayOrder": "9",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Fire Information",
        "groupHelp": "",
        "label": "Sprinkler work proposed?",
        "name": "52109",
        "options": "",
        "readonly": "Y",
        "title": "Sprinkler work proposed?",
        "type": "B",
        "value": ""
      },
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Fire Information",
        "groupHelp": "",
        "label": "Sprinklers Provided?",
        "name": "52110",
        "options": "",
        "readonly": "Y",
        "title": "Sprinklers Provided?",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "25",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Fire Information",
        "groupHelp": "",
        "label": "Standpipes",
        "name": "51445",
        "options": "",
        "readonly": "Y",
        "title": "Standpipes",
        "type": "N",
        "value": ""
      },
      {
        "DisplayOrder": "30",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Fire Information",
        "groupHelp": "",
        "label": "Sprinkler Heads",
        "name": "51450",
        "options": "",
        "readonly": "Y",
        "title": "Sprinkler Heads",
        "type": "N",
        "value": "128"
      },
      {
        "DisplayOrder": "35",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Fire Information",
        "groupHelp": "",
        "label": "Siamese Connections",
        "name": "51455",
        "options": "",
        "readonly": "Y",
        "title": "Siamese Connections",
        "type": "N",
        "value": ""
      },
      {
        "DisplayOrder": "40",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Fire Information",
        "groupHelp": "",
        "label": "Roof Manifold Lines",
        "name": "51460",
        "options": "",
        "readonly": "Y",
        "title": "Roof Manifold Lines",
        "type": "N",
        "value": ""
      },
      {
        "DisplayOrder": "15",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Construction Costs",
        "groupHelp": "",
        "label": "Declared Construction Cost",
        "name": "50405",
        "options": "",
        "readonly": "Y",
        "title": "Declared Construction Cost",
        "type": "N",
        "value": "10276"
      },
      {
        "DisplayOrder": "18",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Construction Costs",
        "groupHelp": "",
        "label": "Declared Sprinkler Cost",
        "name": "51785",
        "options": "",
        "readonly": "Y",
        "title": "Declared Sprinkler Cost",
        "type": "N",
        "value": ""
      },
      {
        "DisplayOrder": "20",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Construction Costs",
        "groupHelp": "",
        "label": "Calculated Construction Cost",
        "name": "50410",
        "options": "",
        "readonly": "Y",
        "title": "Calculated Construction Cost",
        "type": "N",
        "value": ""
      },
      {
        "DisplayOrder": "25",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Construction Costs",
        "groupHelp": "",
        "label": "Contract Price Override",
        "name": "50415",
        "options": "",
        "readonly": "Y",
        "title": "Contract Price Override",
        "type": "B",
        "value": ""
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Construction Costs",
        "groupHelp": "",
        "label": "Exempt from all Permit Fees?",
        "name": "50400",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"IDC\",\"value\":\"IDC\"},{\"label\":\"No\",\"value\":\"No\"},{\"label\":\"Yes\",\"value\":\"Yes\"}]",
        "readonly": "Y",
        "title": "Exempt from all Permit Fees?",
        "type": "C",
        "value": "No"
      },
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Construction Costs",
        "groupHelp": "",
        "label": "Start Review without App Fee?",
        "name": "50401",
        "options": "",
        "readonly": "Y",
        "title": "Start Review without App Fee?",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "12",
        "Mandatory": "Y",
        "RequiredForInitialSetup": "Y",
        "ValueRequired": "Y",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Construction Costs",
        "groupHelp": "",
        "label": "Autobill Non Refundable Fees?",
        "name": "52165",
        "options": "",
        "readonly": "Y",
        "title": "Autobill Non Refundable Fees?",
        "type": "B",
        "value": "Yes"
      },
      {
        "DisplayOrder": "30",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Permit Information",
        "groupHelp": "",
        "label": "Fire Line",
        "name": "51660",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Indepedent\",\"value\":\"Indepedent\"},{\"label\":\"Potable & Fire\",\"value\":\"Potable & Fire\"}]",
        "readonly": "Y",
        "title": "Fire Line",
        "type": "C",
        "value": ""
      },
      {
        "DisplayOrder": "40",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Permit Information",
        "groupHelp": "",
        "label": "Work/Piping within Building?",
        "name": "51670",
        "options": "",
        "readonly": "Y",
        "title": "Work/Piping within Building?",
        "type": "B",
        "value": ""
      },
      {
        "DisplayOrder": "42",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Permit Information",
        "groupHelp": "",
        "label": "Engineered Drawings?",
        "name": "52195",
        "options": "",
        "readonly": "Y",
        "title": "Engineered Drawings?",
        "type": "B",
        "value": ""
      },
      {
        "DisplayOrder": "100",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Permit Information",
        "groupHelp": "",
        "label": "Grand Total Square Feet",
        "name": "53000",
        "options": "",
        "readonly": "Y",
        "title": "Grand Total Square Feet",
        "type": "N",
        "value": "0"
      },
      {
        "DisplayOrder": "20",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Zoning & Land Use Information",
        "groupHelp": "",
        "label": "Interlocal Service Boundary (ISBA)",
        "name": "39000",
        "options": "[{\"label\":\"\",\"value\":\"\"},{\"label\":\"Daytona Beach (DB)\",\"value\":\"Daytona Beach (DB)\"},{\"label\":\"Edgewater (EDG)\",\"value\":\"Edgewater (EDG)\"},{\"label\":\"New Smyrna Beach (NSB)\",\"value\":\"New Smyrna Beach (NSB)\"},{\"label\":\"Oak Hill (OH)\",\"value\":\"Oak Hill (OH)\"},{\"label\":\"Ormond Beach (OB)\",\"value\":\"Ormond Beach (OB)\"}]",
        "readonly": "Y",
        "title": "Interlocal Service Boundary (ISBA)",
        "type": "C",
        "value": ""
      },
      {
        "DisplayOrder": "10",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Property Access",
        "groupHelp": "",
        "label": "Gate Code",
        "name": "52020",
        "options": "",
        "readonly": "Y",
        "title": "Gate Code",
        "type": "A",
        "value": ""
      },
      {
        "DisplayOrder": "5",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Tied Permits",
        "groupHelp": "",
        "label": "Building Permit #",
        "name": "50115",
        "options": "",
        "readonly": "Y",
        "title": "Building Permit #",
        "type": "A",
        "value": "20250117021"
      },
      {
        "DisplayOrder": "15",
        "Mandatory": "N",
        "RequiredForInitialSetup": "N",
        "ValueRequired": "N",
        "Webhelp": "",
        "columnClass": "col-md-6",
        "group": "Tied Permits",
        "groupHelp": "",
        "label": "Electrical Permit #",
        "name": "50100",
        "options": "",
        "readonly": "Y",
        "title": "Electrical Permit #",
        "type": "A",
        "value": ""
      }
    ],
    "open_folder": {
      "Actions": "Detail",
      "Date": "2025-06-03",
      "Description": "Install NFPA 13R wet sprinkler system starting at 1'-0\" AFF  Building 5",
      "File Number": "20250603048",
      "FolderRSN": "1252206",
      "Name": "2360 OCEAN SHORE Boulevard, ORMOND BEACH 32176",
      "Property": "322700010020",
      "Status": "Issued",
      "Type": "FIRE",
      "_id": "f4s/QCbTmaVTQIyzeRK0Lgxce3LTLaQ="
    },
    "people": {
      "Address": "Mr. Robert Dewar,Wayne Automatic Fire Sprinklers Inc. 222 Capitol Ct.",
      "First Name": "Robert",
      "Last Name": "Dewar",
      "People ID": "5618237",
      "People Role": "Fire Sprinkler",
      "PeopleRSN": "5618237",
      "_id": "e487SibQmM63tSP8Eezc4uN/+DLe2RI="
    },
    "record_detail": {
      "Application Date": "June 3, 2025",
      "Expiration Date": "July 11, 2026",
      "Folder Name": "2360 OCEAN SHORE Boulevard, ORMOND BEACH 32176",
      "Issue Date": "June 4, 2025",
      "Reference Number": "20250603048",
      "Status": "Issued",
      "Type": "Fire Permit (Commercial, New Work)",
      "[FullRow]": " ",
      "[FullRow]Condition": "THIS IS FOR BLDG. 5 ONLY\n1. BE SURE APPROVED PLANS AND PERMIT ARE ON SITE FOR INSPECTIONS. \n2. PRIOR TO ANY TIE IN, THE UNDERGROUND SHALL BE INSPECTED, FLUSHED AND WITNESSED BY FIRE. BE SURE TO COORDINATE THIS WITH UNDERGROUND INSTALLER. ANY VIOLATION OF THIS SHALL REQUIRE ALL TO BE RE-DONE. \n3. A FIRE ROUGH SHALL BE DONE WHEN ALL UNITS ARE COMPLETED. THE SYSTEM SHALL BE HYDRO TESTED AT 200 PSI FOR 2-HOURS. ALL PIPE, HANGARS SHALL BE VISIBLE AND NOTHING SHALL BE COVERED. \n4. THE ELEVATOR SHAFT IS EXEMPT FROM SPRINKLER PROVIDED IT MEETS ASME A17.1/CSA B44 REQUIREMENTS. OTHERWISE, A HEAD SHALL BE REQUIRED IN SHAFT. \n5. SPRINKLER HEADS SHALL BE LOCATED WITHIN PROXIMITY OF EACH FLOOR STAIRWELL. IF STAIRWELL IS ENCLOSED, HEADS SHALL BE REQUIRED IN EACH STAIRWELL. THE TOP FLOOR STAIR SHALL HAVE A HEAD ABOVE REGARDLESS. (6.6.9.1)\n6. ANY CLOSET IN THE STAIRWELL, SHALL REQUIRE SPRINKLER COVERAGE. (6.6.9.3)\n7. PLANS DON'T SHOW CLEAR AHU/DRYER TYPE CLOSETS. THESE SHALL REQUIRE INTERMEDIATE TEMP. HEADS (6.6.6.1)\n8. MAKE SURE ALL DISTANCES ARE MET PER TABLE (6.2.3.3.3) FROM ALL HEAT SOURCES.\n9. MAKE SURE ALL DISTANCES FOR FAN OR OTHER OBSTRUCTIONS ARE MET PER TABLE 6.2.6.3.6.2.\n10. WATERFLOW ALARM IS REQUIRED. THESE BUILDINGS HAVE A FIRE ALARM SYSTEM AND THE WATERFLOW SHALL BE TIED INTO THE ALARM SYSTEM. (6.16.1/6.16.2)\n11. ANY UNHEATED SPACE NOT ABLE TO MAINTAIN 40 DEGREES SHALL MEET (5.4.2 (1)-(5)\n12. AFTER ALL CONSTRUCTION WORK HAS BEEN COMPLETED TO INCLUDE PAINTING, THE FIRE SPRINKLER FINAL SHALL BE CONDUCTED. (NOT BEFORE). THE FIRE ALARM AND FIRE SPRINKLER FINAL SHALL BE COORDINATED TOGETHER. ALL SIGNAGE/PLACARD ETC SHALL BE IN PLACE TO INCLUDE FDC, RISER, VALVES ETC. ",
      "[FullRow]Description": "Install NFPA 13R wet sprinkler system starting at 1'-0\" AFF\n\nBuilding 5"
    },
    "registry_license_match": {}
  },
  "source_record_id": "5618237:Fire Sprinkler:20250603048",
  "source_url": "https://connectlivepermits.org/citizenportal/app/",
  "state": "FL",
  "status": "Issued",
  "work_date": "June 4, 2025",
  "work_event_id": "20250603048",
  "work_type": "Fire Permit (Commercial, New Work)",
  "work_value": "10276",
  "work_value_source": "Volusia AMANDA Additional Information Declared Construction Cost"
}
Get this page with API

Rendered from the bluedoor Licensed Contractors API. Reproduce it:

GET https://api.bluedoor.sh/licensed-contractors/v1/work-events/event_59695fac76b16a24cabb?include_source_fields=trueJSON
Install NFPA 13R wet sprinkler system starting at 1'-0" AFF Building 5 — Licensed Contractors data | bluedoor