Home › Work events › EXTENDED 1/5/24(60 DAYS) EXTENDED 10-4-23 (90 DAYS) Installing (9) Antennas, (6) RRUS, ...
EXTENDED 1/5/24(60 DAYS) EXTENDED 10-4-23 (90 DAYS) Installing (9) Antennas, (6) RRUS, ...
Commercial Building event dated 2023-01-23.
Work event
| Work event PK | event_54a86e3188115431a958 |
| Work type | Commercial Antenna |
| Work category | Commercial Building |
| Description | EXTENDED 1/5/24(60 DAYS) EXTENDED 10-4-23 (90 DAYS) Installing (9) Antennas, (6) RRUS, (2) OVP, (2) Hybrids. Ground SOW: Verizon to expand the existing compound and install in a 26’ 11” x 13’ 7” area. In this area will be (1) H-Frame, (1) 4’ x 10’ concrete pad for equipment cabinets, (1) 4’ x 10’ pad for a 50kw propane generator and (1) 4’ x 10’ pad for a 500 gallon propane tank. The propane tank will be designed with an integrated shut off valve to reduce the spark radius to 5’. GENERATOR, PROPANE TANK AND FENCE BY SEPARATE PERMIT ONLY |
| Work date | 2023-01-23 |
| Status | Closed-Certificate Issued |
| Source record ID | BLD2023010970 |
| Jurisdiction | Martin County Accela Building jurisdiction |
Location
| Site address | - |
| City | - |
| County | - |
| State | - |
| Postal code | - |
| Parcel ID | - |
| Latitude | - |
| Longitude | - |
Project value
| Amount | - |
| Type | - |
| Source | - |
| Confidence | - |
Provenance
| Source URL | - |
| Raw payload path | - |
| Imported at | - |
Full work-event record
| Work Event PK | event_54a86e3188115431a958 |
| Firm ID | firm_1572ea676cceff7a6eb3 |
| Local Identity ID | identity_ac69cc4a8bec14d24c16 |
| Portal Key | martin_accela |
| Jurisdiction Scope | Martin County Accela Building jurisdiction |
| Source Record ID | BLD2023010970 |
| Work Event ID | BLD2023010970 |
| Work Type | Commercial Antenna |
| Work Category | commercial_building |
| Description | EXTENDED 1/5/24(60 DAYS) EXTENDED 10-4-23 (90 DAYS) Installing (9) Antennas, (6) RRUS, (2) OVP, (2) Hybrids. Ground SOW: Verizon to expand the existing compound and install in a 26’ 11” x 13’ 7” area. In this area will be (1) H-Frame, (1) 4’ x 10’ concrete pad for equipment cabinets, (1) 4’ x 10’ pad for a 50kw propane generator and (1) 4’ x 10’ pad for a 500 gallon propane tank. The propane tank will be designed with an integrated shut off valve to reduce the spark radius to 5’. GENERATOR, PROPANE TANK AND FENCE BY SEPARATE PERMIT ONLY |
| Observed Project Value | 80,000 |
| Value Type | job_value |
| Value Source | Martin Accela JobValue |
| Value Confidence | high |
| Work Date | 2023-01-23 |
| Status | Closed-Certificate Issued |
| Site Address | 4205 SW RANCHWOOD ST, PALM CITY FL 34990 |
| City | PALM CITY |
| State | FL |
| Postal Code | 34990 |
| County | Martin |
| Parcel ID | 02-39-40-000-053-00000-9 |
| Latitude | 27.106 |
| Longitude | -80.311 |
| Source URL | https://aca-prod.accela.com/MARTINCO/Cap/CapDetail.aspx?Module=Building&TabName=Buildin... |
| Raw Payload Path | - |
| Imported At | 2026-06-03 |
Source Fields
{
"business_display_name": "ASCEND WIRELESS NETWORKS, INC",
"city": "PALM CITY",
"confidence_notes": "Imported from existing Martin Accela permit detail table.",
"county": "Martin",
"description": "EXTENDED 1/5/24(60 DAYS)\r\nEXTENDED 10-4-23 (90 DAYS)\r\nInstalling (9) Antennas, (6) RRUS, (2) OVP, (2) Hybrids. \r\n\r\nGround SOW: Verizon to expand the existing compound and install in a 26’ 11” x 13’ 7” area. In this area will be (1) H-Frame, (1) 4’ x 10’ concrete pad for equipment cabinets, (1) 4’ x 10’ pad for a 50kw propane generator and (1) 4’ x 10’ pad for a 500 gallon propane tank. The propane tank will be designed with an integrated shut off valve to reduce the spark radius to 5’. GENERATOR, PROPANE TANK AND FENCE BY SEPARATE PERMIT ONLY",
"email": "[email protected]",
"insurance_or_bond_summary": null,
"jurisdiction_scope": "Martin County Accela Building jurisdiction",
"latitude": 27.1056844341002,
"legal_or_dba_name": "ASCEND WIRELESS NETWORKS, INC",
"license_number": "CGC1521965",
"license_status": null,
"license_type": "STATE CERT - GENERAL CONTRACTOR CGC1521965",
"longitude": -80.3114846013499,
"mailing_or_firm_address": "756 BUSINESS PARK BLVD STE 103 WINTER GARDENS FL 34787",
"parcel_id": "02-39-40-000-053-00000-9",
"phone": "4158359444",
"portal_key": "martin_accela",
"postal_code": "34990",
"qualifier_name": "ZIRKELBACH, ALAN P",
"raw_payload_path": null,
"scope_layer": "county_permitting_authority",
"site_address": "4205 SW RANCHWOOD ST, PALM CITY FL 34990",
"source_record_id": "BLD2023010970",
"source_url": "https://aca-prod.accela.com/MARTINCO/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=REC23&capID2=00000&capID3=001K1&agencyCode=MARTINCO&IsToShowInspection=",
"state": "FL",
"status": "Closed-Certificate Issued",
"work_date": "2023-01-23",
"work_event_id": "BLD2023010970",
"work_type": "Commercial Antenna",
"work_value": 80000,
"work_value_source": "Martin Accela JobValue"