bluedoor data·Licensed Contractors API·bluedoor.sh ↗

HomeWork eventsInstall new 120 linear foot concrete seawall and cap.

Install new 120 linear foot concrete seawall and cap.

Residential Building event dated 2023-09-22.

Work event

Work event PKevent_372943796331b04f6838
Work typeResidential Seawall
Work categoryResidential Building
DescriptionInstall new 120 linear foot concrete seawall and cap.
Work date2023-09-22
Status-
Source record ID20230965511
JurisdictionCharlotte County Accela Building jurisdiction

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_372943796331b04f6838
Firm IDfirm_4a53b0671b0a4d0dd969
Local Identity IDidentity_89725af2cc25e7f0d46e
Portal Keycharlotte_accela
Jurisdiction ScopeCharlotte County Accela Building jurisdiction
Source Record ID20230965511
Work Event ID20230965511
Work TypeResidential Seawall
Work Categoryresidential_building
DescriptionInstall new 120 linear foot concrete seawall and cap.
Observed Project Value43,860
Value Typeunknown
Value SourceCharlotte Accela Construction Cost
Value Confidencemedium
Work Date2023-09-22
Status-
Site Address24196 YACHT CLUB BLVD, Punta Gorda FL 33955 United States
City-
StateFL
Postal Code-
CountyCharlotte
Parcel ID422319330004
Latitude-
Longitude-
Source URLhttps://aca-prod.accela.com/BOCC/Cap/CapDetail.aspx?Module=Building&TabName=Building&ca...
Raw Payload Pathartifacts/business-backfills/charlotte_accela/run_date=2026-06-04/09-22-2023_09-22-2023_type-all_pages-50_details-all.json
Imported At2026-06-04
Source Fields
{
  "business_display_name": "CLAYTON MICHAEL CROCKER",
  "city": null,
  "confidence_notes": "Live Accela date-window import; value and contractor parsed from public CapDetail page.",
  "county": "Charlotte",
  "description": "Install new 120 linear foot concrete seawall and cap.",
  "email": null,
  "insurance_or_bond_summary": null,
  "jurisdiction_scope": "Charlotte County Accela Building jurisdiction",
  "legal_or_dba_name": "CLAYTON MICHAEL CROCKER",
  "license_number": "CBC1266139",
  "license_status": null,
  "license_type": "C BUILDING  CBC1266139",
  "mailing_or_firm_address": "CROCKER MARINE SERVICES INC NORTH FORT MYERS FL 33903",
  "parcel_id": "422319330004",
  "phone": "2398419674",
  "portal_key": "charlotte_accela",
  "postal_code": null,
  "qualifier_name": "9780 LITTLETON RD",
  "raw_payload_path": "artifacts/business-backfills/charlotte_accela/run_date=2026-06-04/09-22-2023_09-22-2023_type-all_pages-50_details-all.json",
  "scope_layer": "county_permitting_authority",
  "site_address": "24196 YACHT CLUB BLVD, Punta Gorda FL 33955 United States",
  "source_fields": {
    "detail": {
      "detail_text_sample": "Accela Citizen Access\nLogin\nRegister for an Account\n|\nAnnouncements\n(\n)\n|\nMark as Read\nmore\nmore\nMessage Bar\nPermit\n20230965511\n:\nResidential Seawall\nRecord Status:\nClosed\nCreate a New Collection\n*\nName:\nDescription:\nAdd\nCancel\nRecord Info\nPermit Details\nReview Status\nRelated Permits\nAttachments\nInspections\nValuation Calculator\nPayments\nFees\nTrust Account Information\nConditions\nMore...\nCustom Component\nView your\nPlan Review\ncomments by clicking the \"Record Info\" menu above then select \"Review Status\".\nIMPORTANT:\nView and print your\nJOB CARD\nby clicking the \"Print/View Job Card\" button at the bottom of the screen.\nNote:  You\nmust be logged in to the permitting site\nto print or view your Job Card.\nJob Site Location:\n24196 YACHT CLUB BLVD\nPunta Gorda FL 33955\nADDRESSKEY: 10823\nADDID: 213485\nHISTORICAL: HISTORICAL\n*\nPermit Details\nApplicant:\nCLAYTON\nMICHAEL\nCROCKER\nCROCKER MARINE SERVICES INC\n9780 LITTLETON RD\nNORTH FORT MYERS,\nFL,\n33903\nHome Phone:\n2398419674\[email protected]\nLicensed Professional:\nCLAYTON MICHAEL CROCKER\nCROCKER MARINE SERVICES INC\n9780 LITTLETON RD\nNORTH FORT MYERS, FL, 33903\nHome Phone:\n2398419674\nC BUILDING  CBC1266139\nJob Description:\nInstall new 120 linear foot concrete seawall and cap.\nOwner:\nBOND KENNETH RALPH\n*\n10660 DEAL RD\nNORTH FORT MYERS FL 33917\nMore Details\nRelated Contacts\nAgent information\nCLAYTON\nMICHAEL\nCROCKER\nCROCKER MARINE SERVICES INC\n9780 LITTLETON RD\nNORTH FORT MYERS, FL, 33903\nHome Phone:\n2398419674\nE-mail:\[email protected]\nOwner information\nMICHAEL\nNORTH FORT MYERS, FL, 33917\nOwner information\nMICHAEL\nNORTH FORT MYERS, FL, 33917\nApplication Information\nGENERAL\nInspection Notification Options:\nReceive EMAIL and TEXT\nExpiration Date:\n11/18/2024\nConstruction Cost:\n43860.00\nStorm related repair/replacement?:\nNo\nStorm Name:\nNot Applicable\nSEAWALL\nBody of Water Type:\nMan Made\nAdditional Electrical Work or Changes in Lighting?:\nNo\nNew/Repair:\nNew\nSeawall LF:\n120\nMaterial:\nConcrete\nAccess to Job:\nWater\nPLAN ROOM ACKNOWLEDGEMENT\nI acknowledge that I will upload plans, supporting documentation, and attachments after paying for my application.:\nYes\nParcel Information\nParcel Number:422319330004\n*\nBlock:000P\nLot:0004\nSubdivision:PIR\nBLDG_TOTAL_AREA: 1810\nDOC_EXEMPT: N\nLAND_USE: Single Family Residential\nASSESSED_VALUE: 374586\nTAX_DISTRICT: 104\nACLF: N\nTURTLEZONE: OUT\nFZONE: 9AE\nFLOODWAY: OUT\nL1_SUBDIVISION: PIR\nISLAND: undefined\nFees\nLoading...\nInspections\nThe inspections specific to your job are listed below under \"Upcoming Inspections\" with a status of \"Pending.\" To schedule an inspection listed as \"Pending,\" click the \"Action\" button next to the inspection and select \"Schedule.\"\nPlease review this section carefully to ensure that all required inspections are scheduled and completed as needed throughout the duration of the project.\nTo schedule CCU and Health Department inspections, please reach out to the corresponding office directly.\nCharlotte County Utilities (CCU) Inspections\nCall 941-764-4300 option 3 (water/sewer), for these inspection types:\nCCU Gravity Sewer\nCCU LPS Connection\nCCU Meter Installation\nCCU Vacuum Sewer\nCall 941-764-4589 for:\nCCU Backflow Preventor\nCall 941-764-4387 for:\nCCU Interceptor\nFlorida Department of Health Inspections\nTo schedule a Health Approval Inspection, please call 941-624-7200.\nLoading...\nUpcoming Inspections\nYou have not added any inspections.\nCompleted\nThere are no completed inspections on this record.\nAttachments\n***ATTACHMENT INSTRUCTIONS***\nImportant:  If attaching either of these document types, please upload\nafter\npermit payment.\nAFFIDAVIT FOR NO ZONING INSPECTION\n: If you are submitting an Affidavit for No Zoning Inspection, your PDF document\nmust\nbe named\nWaiveZoning\n(case sensitive) for correct processing.\nPLANS CHANGES\n:  If you are submitting a\nPlans Change\ndocument, your PDF document\nmust\nbe named\nresubmittal.pdf\nfor correct processing.\nPlease do not add any additional verbiage or special characters.\nPlease limit t",
      "job_value": "43860.00",
      "licensed_professional": {
        "city": "NORTH FORT MYERS",
        "city_state_zip": "NORTH FORT MYERS, FL, 33903",
        "company": "CLAYTON MICHAEL CROCKER",
        "license_holder": "9780 LITTLETON RD",
        "license_notes": "C BUILDING  CBC1266139",
        "phones": {
          "home_phone": "2398419674"
        },
        "postal_code": "33903",
        "state": "FL",
        "street_address": "CROCKER MARINE SERVICES INC"
      },
      "licensed_professional_raw": "CLAYTON MICHAEL CROCKER | CROCKER MARINE SERVICES INC | 9780 LITTLETON RD | NORTH FORT MYERS, FL, 33903 | Home Phone: 2398419674 | C BUILDING  CBC1266139",
      "owner": "BOND KENNETH RALPH",
      "pcn": "422319330004",
      "value_label": "Construction Cost"
    },
    "grid_cells": [
      "",
      "09/22/2023",
      "20230965511",
      "Residential Seawall",
      "Install new 120 linear foot concrete seawall and cap.",
      "Closed",
      "24196 YACHT CLUB BLVD, Punta Gorda FL 33955 United States",
      "",
      "24196 YACHT CLUB BLVD, Punta Gorda FL 33955 United States"
    ],
    "grid_inferred": {
      "application_date": "09/22/2023",
      "description": "Install new 120 linear foot concrete seawall and cap.",
      "record_type": "Residential Seawall",
      "site_address": "24196 YACHT CLUB BLVD, Punta Gorda FL 33955 United States",
      "status": null
    },
    "work_category": "residential_building"
  },
  "source_record_id": "20230965511",
  "source_url": "https://aca-prod.accela.com/BOCC/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=23SE&capID2=00000&capID3=00216&agencyCode=BOCC&IsToShowInspection=",
  "state": "FL",
  "status": null,
  "work_date": "2023-09-22",
  "work_event_id": "20230965511",
  "work_type": "Residential Seawall",
  "work_value": 43860,
  "work_value_source": "Charlotte Accela Construction Cost"
}
Get this page with API

Rendered from the bluedoor Licensed Contractors API. Reproduce it:

GET https://api.bluedoor.sh/licensed-contractors/v1/work-events/event_372943796331b04f6838?include_source_fields=trueJSON