Source Fields
{
"business_display_name": "KEENER MECHANICAL SERVICES INC",
"confidence_notes": "Mapped from Accela Building Search by Record Information plus CapDetail; date window and record type are public search criteria.",
"contractor_license_number": "CMC057204",
"contractor_name": "KEENER MECHANICAL SERVICES INC",
"county": "Osceola",
"description": "Equipment: (3) Ducted split-system units by Carrier / (1) 5 ton 16 SEER, (1) 6 ton 11.5 EER/12.9 IEER, and (1) 7.5 ton 11.2 EER/14.0 IEER Units. (3) Ceiling mounted bathroom exhaust fans. (1) Wall mounted heater. Smoke Detectors: (3) Smoke detector furnished and installed by KMS, wired by others Piping: Refrigerant and condensate piping per manufacturers recommendations Ductwork: Supply & Return ductwork in exposed areas is to be internally lined square duct and 2-inch double wall spiral pipe. In covered ceiling areas it will be externally wrapped metal duct.Dampers: (22) round duct mounted volume dampers Grilles: (18) Supply grilles, (14) Sidewall supply grilles and (6) Return grilles Controls: (3) New programmable thermostat Test & Balance 38.70 SEERS 18.5 TONS Manufacturer: Carrier",
"email": "[email protected]",
"jurisdiction_scope": "Osceola County Citizen Access Building module",
"legal_or_dba_name": "KEENER MECHANICAL SERVICES INC",
"license_number": "CMC057204",
"license_type": "",
"mailing_or_firm_address": "10601 SUMMIT LAKES LANE CLERMONT, FL, 34711",
"normalized_license_number": "CMC057204",
"observed_project_value": "84000.00",
"parcel_id": "2725272985TRACFD20",
"phone": "3522438159",
"portal_key": "osceola_accela_building",
"qualifier_name": "GLENN RAYMOND SCHWENNEKER",
"raw_payload_path": "artifacts/business-backfills/osceola_accela_building/run_date=2026-06-05/date-2019-11-21_all-permit-types/grid-records.json",
"scope_layer": "county_permitting_authority",
"site_address": "7750 SANDY RIDGE DR, KISSIMMEE 34747",
"source_fields": {
"detail": {
"description": "COMM-Mechanical",
"job_value": "84000.00",
"licensed_professional": {
"company": "KEENER MECHANICAL SERVICES INC",
"description": "",
"email": "[email protected]",
"license_number": "CMC057204",
"license_type": "",
"mailing_address": "10601 SUMMIT LAKES LANE CLERMONT, FL, 34711",
"parts": [
"GLENN RAYMOND SCHWENNEKER [email protected]",
"KEENER MECHANICAL SERVICES INC",
"10601 SUMMIT LAKES LANE",
"CLERMONT, FL, 34711",
"Home Phone:",
"3522438159",
"CONTRACTOR CMC057204"
],
"phone": "3522438159",
"qualifier_name": "GLENN RAYMOND SCHWENNEKER",
"raw": "GLENN RAYMOND SCHWENNEKER [email protected] | KEENER MECHANICAL SERVICES INC | 10601 SUMMIT LAKES LANE | CLERMONT, FL, 34711 | Home Phone: | 3522438159 | CONTRACTOR CMC057204"
},
"owner": "",
"pcn": "2725272985TRACFD20",
"record_type": "Mechanical Permit",
"status": "Final"
},
"grid": {
"cells": [
"",
"11/21/2019",
"A19-008160",
"Mechanical Permit",
"COMM-Mechanical",
"7750 SANDY RIDGE DR, KISSIMMEE 34747",
"Final",
"",
"Equipment: (3) Ducted split-system units by Carrier / (1) 5 ton 16 SEER, (1) 6 ton 11.5 EER/12.9 IEER, and (1) 7.5 ton 11.2 EER/14.0 IEER Units. (3) Ceiling mounted bathroom exhaust fans. (1) Wall mounted heater. Smoke Detectors: (3) Smoke detector furnished and installed by KMS, wired by others Piping: Refrigerant and condensate piping per manufacturers recommendations Ductwork: Supply & Return ductwork in exposed areas is to be internally lined square duct and 2-inch double wall spiral pipe. In covered ceiling areas it will be externally wrapped metal duct.Dampers: (22) round duct mounted volume dampers Grilles: (18) Supply grilles, (14) Sidewall supply grilles and (6) Return grilles Controls: (3) New programmable thermostat Test & Balance 38.70 SEERS 18.5 TONS Manufacturer: Carrier",
"",
"",
"7750 SANDY RIDGE DR, KISSIMMEE 34747"
],
"description": "Equipment: (3) Ducted split-system units by Carrier / (1) 5 ton 16 SEER, (1) 6 ton 11.5 EER/12.9 IEER, and (1) 7.5 ton 11.2 EER/14.0 IEER Units. (3) Ceiling mounted bathroom exhaust fans. (1) Wall mounted heater. Smoke Detectors: (3) Smoke detector furnished and installed by KMS, wired by others Piping: Refrigerant and condensate piping per manufacturers recommendations Ductwork: Supply & Return ductwork in exposed areas is to be internally lined square duct and 2-inch double wall spiral pipe. In covered ceiling areas it will be externally wrapped metal duct.Dampers: (22) round duct mounted volume dampers Grilles: (18) Supply grilles, (14) Sidewall supply grilles and (6) Return grilles Controls: (3) New programmable thermostat Test & Balance 38.70 SEERS 18.5 TONS Manufacturer: Carrier",
"detail": {
"description": "COMM-Mechanical",
"job_value": "84000.00",
"licensed_professional": {
"company": "KEENER MECHANICAL SERVICES INC",
"description": "",
"email": "[email protected]",
"license_number": "CMC057204",
"license_type": "",
"mailing_address": "10601 SUMMIT LAKES LANE CLERMONT, FL, 34711",
"parts": [
"GLENN RAYMOND SCHWENNEKER [email protected]",
"KEENER MECHANICAL SERVICES INC",
"10601 SUMMIT LAKES LANE",
"CLERMONT, FL, 34711",
"Home Phone:",
"3522438159",
"CONTRACTOR CMC057204"
],
"phone": "3522438159",
"qualifier_name": "GLENN RAYMOND SCHWENNEKER",
"raw": "GLENN RAYMOND SCHWENNEKER [email protected] | KEENER MECHANICAL SERVICES INC | 10601 SUMMIT LAKES LANE | CLERMONT, FL, 34711 | Home Phone: | 3522438159 | CONTRACTOR CMC057204"
},
"owner": "",
"pcn": "2725272985TRACFD20",
"record_type": "Mechanical Permit",
"status": "Final"
},
"detail_url": "https://permits.osceola.org/CitizenAccess/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=REC19&capID2=00000&capID3=013WH&agencyCode=OSCEOLA&IsToShowInspection=",
"headers": [
"",
"Date",
"Record Number",
"Record Type",
"Project Name",
"Address",
"Status",
"Action",
"Description",
"Expiration Date",
"Short Notes",
""
],
"hidden_record_id": "REC19-00000-013WH",
"record_date": "11/21/2019",
"record_number": "A19-008160",
"record_type": "Mechanical Permit",
"site_address": "7750 SANDY RIDGE DR, KISSIMMEE 34747",
"status": "Final"
}
},
"source_record_id": "A19-008160",
"source_url": "https://permits.osceola.org/CitizenAccess/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=REC19&capID2=00000&capID3=013WH&agencyCode=OSCEOLA&IsToShowInspection=",
"state": "FL",
"status": "Final",
"work_date": "11/21/2019",
"work_event_id": "A19-008160",
"work_type": "Mechanical Permit",
"work_value": "84000.00",
"work_value_source": "Osceola County Accela Citizen Access Building Applicant Job Value"
}