bluedoor data·Licensed Contractors API·bluedoor.sh ↗

HomeWork eventsOne Single Phase 600A Panel Feeds (9) Pedestals, Servicing (18) Slips. Each Pedestal is...

One Single Phase 600A Panel Feeds (9) Pedestals, Servicing (18) Slips. Each Pedestal is...

Electrical event dated 2026-04-22.

Work event

Work event PKevent_1559431b8e6be2962a5e
Work typeCommercial Electrical
Work categoryElectrical
DescriptionOne Single Phase 600A Panel Feeds (9) Pedestals, Servicing (18) Slips. Each Pedestal is Protected by a 100A 240V Breaker. A Used 32,000 LB Lift will Be Installed- Requiring 30A @ 240V- Slip #5-1 The Pedestal Serving Slips #5-1 and #5-2 is Powered At 100A @ 240V. The Sharing Slip Has NO Lift. It is Occupied By A Boat Using 50A Shore Power. EACH PEDESTAL SERVES (2) SLIPS AS FOLLOWS: Pedestal #36 30A Lift No Boat No Lift Pedestal #37 No Boat No Lift 30A Lift Pedestal #38 30A Lift No Boat No Lift Pedestal #39 No Lift- NO Power Being Used 30A Lift Pedestal #40 30A Lift No Lift- NO Power Being Used Pedestal #41 **TO BE INSTALLED ** 30a Lift No Lift- 50A Shore Power Being Used. Pedestal #42 no Lift- No Power Being Used No Lift NO Boat Pedestal #43 No Lift- 50A Shore Power Being Used No Boat No Lift Pedestal #44 No Lift- 50A Shore Power Being Used No Lift No Boat
Work date2026-04-22
StatusIssued
Source record IDBLD2026041139
JurisdictionMartin County Accela Building jurisdiction

Location

Site address-
City-
County-
State-
Postal code-
Parcel ID-
Latitude-
Longitude-

Project value

Amount-
Type-
Source-
Confidence-

Provenance

Source URL-
Raw payload path-
Imported at-

Full work-event record

Work Event PKevent_1559431b8e6be2962a5e
Firm IDfirm_9051066771ccb7b7f135
Local Identity IDidentity_701a531df6ef8e17876e
Portal Keymartin_accela
Jurisdiction ScopeMartin County Accela Building jurisdiction
Source Record IDBLD2026041139
Work Event IDBLD2026041139
Work TypeCommercial Electrical
Work Categoryelectrical
DescriptionOne Single Phase 600A Panel Feeds (9) Pedestals, Servicing (18) Slips. Each Pedestal is Protected by a 100A 240V Breaker. A Used 32,000 LB Lift will Be Installed- Requiring 30A @ 240V- Slip #5-1 The Pedestal Serving Slips #5-1 and #5-2 is Powered At 100A @ 240V. The Sharing Slip Has NO Lift. It is Occupied By A Boat Using 50A Shore Power. EACH PEDESTAL SERVES (2) SLIPS AS FOLLOWS: Pedestal #36 30A Lift No Boat No Lift Pedestal #37 No Boat No Lift 30A Lift Pedestal #38 30A Lift No Boat No Lift Pedestal #39 No Lift- NO Power Being Used 30A Lift Pedestal #40 30A Lift No Lift- NO Power Being Used Pedestal #41 **TO BE INSTALLED ** 30a Lift No Lift- 50A Shore Power Being Used. Pedestal #42 no Lift- No Power Being Used No Lift NO Boat Pedestal #43 No Lift- 50A Shore Power Being Used No Boat No Lift Pedestal #44 No Lift- 50A Shore Power Being Used No Lift No Boat
Observed Project Value2,000
Value Typejob_value
Value SourceMartin Accela JobValue
Value Confidencehigh
Work Date2026-04-22
StatusIssued
Site Address262 SW PALM COVE DR, PALM CITY FL 34990
CityPALM CITY
StateFL
Postal Code34990
CountyMartin
Parcel ID06-38-41-019-000-00001-0
Latitude27.203
Longitude-80.284
Source URLhttps://aca-prod.accela.com/MARTINCO/Cap/CapDetail.aspx?Module=Building&TabName=Buildin...
Raw Payload Path-
Imported At2026-06-03
Source Fields
{
  "business_display_name": "STEVE'S ELECTRIC OF SOUTH FLORIDA, INC",
  "city": "PALM CITY",
  "confidence_notes": "Imported from existing Martin Accela permit detail table.",
  "county": "Martin",
  "description": "One Single Phase 600A Panel Feeds (9) Pedestals, Servicing (18) Slips.\nEach Pedestal is Protected by a 100A 240V Breaker. \nA Used 32,000 LB Lift will Be Installed- Requiring 30A @ 240V- Slip #5-1\nThe Pedestal Serving Slips #5-1 and #5-2 is Powered At 100A @ 240V.\nThe Sharing Slip Has NO Lift. It is Occupied By A Boat Using 50A Shore Power.\n\nEACH PEDESTAL SERVES (2) SLIPS AS FOLLOWS:\n\nPedestal #36\n30A Lift\nNo Boat No Lift\n\nPedestal #37\nNo Boat No Lift\n30A Lift\n\nPedestal #38\n30A Lift\nNo Boat No Lift\n\nPedestal #39\nNo Lift- NO Power Being Used\n30A Lift\n\nPedestal #40\n30A Lift\nNo Lift- NO Power Being Used\n\nPedestal #41\n**TO BE INSTALLED ** 30a Lift\nNo Lift- 50A Shore Power Being Used.\n\nPedestal #42\nno Lift- No Power Being Used\nNo Lift NO Boat\n\nPedestal #43\nNo Lift- 50A Shore Power Being Used\nNo Boat No Lift\n\nPedestal #44\nNo Lift- 50A Shore Power Being Used\nNo Lift No Boat",
  "email": "[email protected]",
  "insurance_or_bond_summary": null,
  "jurisdiction_scope": "Martin County Accela Building jurisdiction",
  "latitude": 27.2026318924654,
  "legal_or_dba_name": "STEVE'S ELECTRIC OF SOUTH FLORIDA, INC",
  "license_number": "EC13009955",
  "license_status": null,
  "license_type": "STATE CERT - ELECTRICAL  EC13009955",
  "longitude": -80.2843034413609,
  "mailing_or_firm_address": "3810 CROSSROADS PKWY FT PIERCE FL 34945",
  "parcel_id": "06-38-41-019-000-00001-0",
  "phone": "7728738730",
  "portal_key": "martin_accela",
  "postal_code": "34990",
  "qualifier_name": "ABBOTT, GLEN A",
  "raw_payload_path": null,
  "scope_layer": "county_permitting_authority",
  "site_address": "262 SW PALM COVE DR, PALM CITY FL 34990",
  "source_record_id": "BLD2026041139",
  "source_url": "https://aca-prod.accela.com/MARTINCO/Cap/CapDetail.aspx?Module=Building&TabName=Building&capID1=REC26&capID2=00000&capID3=008S4&agencyCode=MARTINCO&IsToShowInspection=",
  "state": "FL",
  "status": "Issued",
  "work_date": "2026-04-22",
  "work_event_id": "BLD2026041139",
  "work_type": "Commercial Electrical",
  "work_value": 2000,
  "work_value_source": "Martin Accela JobValue"
}