| bury 500 gallon propane tank. Run 115 feet, 3/4 inch P.E.... | 2026-06-01 | Gas Line / bury 500 gallon propane tank. Run 115 feet, 3/4 inch P.E. @ 10 PSI exterior piping to generator, tankless water heater (installed by others) and 2 house stubouts. Run 200 feet interior piping to (2) ranges, (2) dryers, fireplace and (5) laterns. 80 feet, 3/4 inch galvanized piping, 120 feet, 3/4 inch CSST. Run 50 feet, 3/4 inch CSST to range, firelogs and (2) gas lanterns(installed by others) on a 2nd stage register and running 70 feet, 3/4 inch CSST to (2) dryers, (2) gas lanterns and range on a separate 2nd stage regulator. | - | - |
| run 25 feet, 3/4 inch P.E. @ 2 PSI to new pool heater (in... | 2026-05-12 | Pool / Gas Line / run 25 feet, 3/4 inch P.E. @ 2 PSI to new pool heater (installed by others), tying into existing natural gas meter | - | - |
| run 35 feet, 3/4 inch P.E. @ 2 PSI to pool heater(install... | 2026-05-01 | Pool / Gas Line / run 35 feet, 3/4 inch P.E. @ 2 PSI to pool heater(installed by others), tying into existing gas line at meter | - | - |
| run 20 feet, 3/4 inch P.E. @ 2 PSI from existing natural ... | 2026-04-08 | Pool / Gas Line / run 20 feet, 3/4 inch P.E. @ 2 PSI from existing natural gas meter to new 400,000 BTU pool heater(installed by others). Run 20 feet, 3/4 inch P.E. @ 6-12 inch W.C to 60,000 BTU grill(installed by others) | - | - |
| run 25 feet, 1 inch P.E. @ 6-12 inch W.C. from existing n... | 2026-04-03 | Gas Permit | - | - |
| run 35 feet, 3/4 inch P.E. from existing natural gas mete... | 2026-03-20 | Pool / Gas Line / run 35 feet, 3/4 inch P.E. from existing natural gas meter to new 400,000 BTU pool heater (installed by others) @ 2 PSI(tying into existing meter). Run 35 feet, 3/4 inch P.E. @ 6-12 inch W.C. to 40,000 BTU natural gas firepit (installed by others). Portion of gas line going into pool enclosure will be run in 2-1/2 inch chase(PVC) | - | - |
| connecting new natural gas pool heater, 400,000 BTU's, Fi... | 2026-03-06 | Pool / Gas Line / connecting new natural gas pool heater, 400,000 BTU's, Firepit 60,000 BTU and Grill 60,000 BTU, (pool heater firepit and grill installed by others) to existing gas meter, using 70 feet, 3/4 inch P.E. @ 2 PSI | - | - |
| run 40 feet, 3/4 inch galvanized piping to pool heater(in... | 2026-02-16 | Pool / Gas Line / run 40 feet, 3/4 inch galvanized piping to pool heater(installed by others), 30 feet, 3/4 inch CSST, tying into existing gas line. run 10 feet, 3/4 galvanized piping to grill(installed by others) | - | - |
| run 35 feet, 3/4 inch P.E. @ 2 PSI to new natural gas poo... | 2026-02-06 | Pool / Gas Line / run 35 feet, 3/4 inch P.E. @ 2 PSI to new natural gas pool heater(installed by others). Tie into existing gas line at natural gas meter | - | - |
| tie into existing natural gas line in attic; run 25 feet,... | 2026-02-02 | Pool / Gas Line / tie into existing natural gas line in attic; run 25 feet, 3/4 inch CSST @ 2 PSI and 7 feet, 3/4 inch galvanized piping to new pool heater(installed by others) | - | - |
| connect 400,000 BTU's pool heater(installed by others) to... | 2026-01-27 | Pool / Gas Line / connect 400,000 BTU's pool heater(installed by others) to existing natural gas meter, using 35 feet, 3/4 inch P.E. @ 2 PSI | - | - |
| run 50 feet, 3/4 inch P.E. @ 2 PSI from existing natural ... | 2026-01-22 | Pool / Gas Line / run 50 feet, 3/4 inch P.E. @ 2 PSI from existing natural gas meter to new 400,000 BTU natural gas pool heater (installed by others) | - | - |
| tie into existing natural gas line in attic; run 15 feet,... | 2026-01-07 | Pool / Gas Line / tie into existing natural gas line in attic; run 15 feet, 3/4 inch CSST @ 2 PSI and 8 feet, 3/4 inch galvanized piping to new pool heater(installed by others) | - | - |
| Run 30 feet, 3/4 inch P.E. @ 2 PSI from existing natural ... | 2025-12-19 | Pool / Gas Line / Run 30 feet, 3/4 inch P.E. @ 2 PSI from existing natural gas meter to new 400,000 BTU pool heater(installed by others) | - | - |
| Run 35 feet, 3/4 inch P.E. @ 2 PSI from existing natural ... | 2025-12-18 | Pool / Gas Line / Run 35 feet, 3/4 inch P.E. @ 2 PSI from existing natural gas meter to new 400,000 BTU pool heater(installed by others) | - | - |
| Run 30 feet, 3/4 inch P.E. @ 2 PSI from existing natural ... | 2025-12-16 | Pool / Gas Line / Run 30 feet, 3/4 inch P.E. @ 2 PSI from existing natural gas meter to new pool heater(installed by others. Run 10 feet, 3/4 inch P.E. @ 6:-13+ W.C. to grill(installed by others) | - | - |
| line and tank: set 250 gallon above ground propane tank, ... | 2025-09-18 | Gas Line / line and tank: set 250 gallon above ground propane tank, running 12 feet. 3/4 inch P.E. to generator(installed by others). Tank will be set 10 feet off property line and 12 feet from generator | - | - |
| gas and line. run 30 feet, 1/2 inch galvanized piping @ 9... | 2025-09-12 | Gas Line / gas and line. run 30 feet, 1/2 inch galvanized piping @ 9"-14" W.C. to range. Set propane tank(not filled on site) and make final connections to range. | - | - |
| run 175 feet, 3/4 inch P.E. piping to new pool heater, gr... | 2025-09-09 | Pool / Gas Line / run 175 feet, 3/4 inch P.E. piping to new pool heater, grill and firepit(installed by others). Tie into existing gas line at water heater | - | - |
| Tie into existing natural gas line, running 30 feet, 3/4 ... | 2025-08-26 | Gas Line / Tie into existing natural gas line, running 30 feet, 3/4 inch CSST and 10 feet, 3/4 inch galvanized piping | - | - |
| connect new pool heater(installed by others) to existing ... | 2025-08-13 | Pool / Gas Line / connect new pool heater(installed by others) to existing natural gas line in attic, using 50 feet, 3/4 inch CSST @ 2 PSI and 50 feet, 3/4 inch P.E. @ 2 PSI | - | - |
| run 90 feet, 3/4 inch P.E. from existing natural gas line... | 2025-05-05 | Pool / Gas Line / run 90 feet, 3/4 inch P.E. from existing natural gas line to new natural gas fire pit(installed by others); run 30 feet, 3/4 inch CSST tying into existing gas line to new natural gas pool heater (installed by others) | - | - |
| Run 35 feet of 3/4 inch P.E. to new natural gas pool heat... | 2025-04-04 | Pool / Gas Line / Run 35 feet of 3/4 inch P.E. to new natural gas pool heater (installed by others). This project is for 1932 Laura Loop | - | - |
| Connecting Natural Gas Meter to pool heater (installed by... | 2025-03-31 | Pool / Gas Line / Connecting Natural Gas Meter to pool heater (installed by others), 400,000 BTU's, using 20 feet, 3/4 inch P.E. @ 2 PSI; connect grill (installed by others) 40,000 BTU's, using 15 feet, 3/4 inch P.E. @ 2 PSI; connect Fire Pit (installed by others), 60,000 BTU's using 40 feet, 3/4 inch P.E. @ 2 PSI | - | - |
| run 120 feet gas piping tying into existing gas line in a... | 2025-02-26 | Pool / Gas Line / run 120 feet gas piping tying into existing gas line in attic, to new pool heater and grill | - | - |
| connect existing 250 gallon AG propane tank to 22kw, 400,... | 2024-12-12 | Gas Line / connect existing 250 gallon AG propane tank to 22kw, 400,000 generator(installed by others) | - | - |
| Tie grill and pool heater into existing natural gas meter | 2024-11-19 | Pool / Gas Line / Tie grill and pool heater into existing natural gas meter | - | - |
| connect 400,000BTU pool heater(installed by others) to ex... | 2024-11-12 | Pool / Gas Line / connect 400,000BTU pool heater(installed by others) to existing natural gas meter using 20 feet, 3/4 inch P.E. @ 2 PSI | - | - |
| Set 250 gallon propane tank AG. Run 10 feet, 3/4 inch P.,... | 2024-09-12 | Gas Permit | - | - |
| Mr. Fugua is a disabled veteran and Purple Heart recipien... | 2023-06-23 | Plumbing / Residential Plumbing Trade Permit | - | - |