Permits and public work events attributed to this contractor. Showing 9 rows on page 1.

Work eventDateCategory / typeCountyValue
Replace existing 200 amp Square D QO panel with new 200 a...2023-10-04Replace existing 200 amp Square D QO panel with new 200 amp Square D QO panel. Install surge protection.--
Replace existing 200amp panel with new 200amp panel. Upda...2023-09-13Replace existing 200amp panel with new 200amp panel. Update grounding per code. Install surge protection. Install 50amp generator inlet.--
Electrician to add ground junction box 15 wire 10 foot co...2023-08-29Electrical / Electrician to add ground junction box 15 wire 10 foot conduit--
Supply and install 5 LED area lights on existing poles, w...2023-08-02Supply and install 5 LED area lights on existing poles, we will junction existing wiring and install in conduit up poles to new fixture.--
Replace existing 200amp sub panel with new 200amp square ...2023-07-31Replace existing 200amp sub panel with new 200amp square D QO 40 space main breaker panel. Update grounding to code. Install whole home surge protector. Install 30amp generator inlet.--
Replace existing 200amp 30 space main lug panel with new ...2023-07-21Replace existing 200amp 30 space main lug panel with new 200amp 42 space main lug panel. Install whole home surge protection. Update grounding per code.--
****REVISION - Not doing whole home surge protector*****2023-07-14****REVISION - Not doing whole home surge protector*****--
> KITCHEN * Installed a 20 amp dual function AFCI/GFCI br...2023-07-10Landscaping / > KITCHEN * Installed a 20 amp dual function AFCI/GFCI breaker within the panel to protect the kitchen counter top circuit within rage of the sink, verified proper function of breaker and protection. * Ran a new wire to replace the Romex within the cabinets that supplied power to the under cabinet lighting. Wire used was MC which is crush resistant and safe to be within a cabinet > MASTER BEDROOM * Secured a loose outlet along the back wall that was not tightened all the way. > GENERAL GFCI PROTECTION * Installed a 15 AMP GFCI breaker within the panel to protect all guest bathroom outlets and lanai outlets outside, tested and verified protection. * Installed a GFCI outlet inside the garage on the left to protect that outlet along with the outlet in the master bathroom. * installed a GFCI outlet inside the garage on the right to protect the two outlets per code. > LANAI OUTLET * The outlet that was on the lanai which was stated had no power was a switched outlet to control landscape lighting and worked properly. * Replaced the standard outlet with a GFCI because it wasn’t before hand. > GARAGE LIGHTING * Converted 2 96 inch Fluorescent fixtures to accept LED bypass bulbs * Installed 4 LED 96 inch LED bulbs and verified proper function. > ATTIC JUNCTION BOXES * Installed a metal 4 square blank onto an open junction box within the attic * Contained an open splice within a plastic junction box with a blank cover. > PANEL * A disconnected surge protector was removed from the bottom of the panel.--
-Remove existing 200 amp Disconnect. -Install new 200 amp...2023-06-29-Remove existing 200 amp Disconnect. -Install new 200 amp Square D QO Disconnect at existing location. -Upgrade grounding to code.--
End of resultsBack to contractor