bluedoor data·Job Postings API·bluedoor.sh ↗

HomeCompaniesMentortechnicalgroupFacilities Electrician (Regulated Industry)

Facilities Electrician (Regulated Industry)

Mentortechnicalgroup · Redwood City, CA · Active · JazzHR / ApplyToJob

Job facts

FieldValue
CompanyMentortechnicalgroup
TitleFacilities Electrician (Regulated Industry)
Normalized title-
Department / team-
LocationRedwood City, CA, United States
Work model-
Employment typeFull Time
Salary-
Statusactive
ATS providerJazzHR / ApplyToJob
Posted / first seen2026-05-12 / 2026-05-30
Changed / last seen2026-05-30 / 2026-06-06

Related slices

PageWhat it containsOpen
Company jobsActive postings from Mentortechnicalgroup.Open
Company breakdownsRole, location, ATS, and work model facets for this company.Open
ATS provider jobsActive postings observed through JazzHR / ApplyToJob.Open
Provider filtered searchThe same provider as a filtered job collection.Open
City jobsActive postings in Redwood City.Open
Lifecycle eventsOpen, update, close, and reopen events for this posting.Open
Original postingCanonical source or apply URL captured from the ATS.Open

Linked records

CompanyMentortechnicalgroup
Sourcef5fcad81-5e27-438a-9b9c-61af3019fe6d
ATS providerJazzHR / ApplyToJob

Description

Mentor Technical Group (MTG) provides a comprehensive portfolio of technical support and solutions for the FDA-regulated industry. As a world leader in life science engineering and technical solutions, MTG has the knowledge and experience to ensure compliance with pharmaceutical, biotechnology, and medical device safety and efficacy guidelines. With offices in Caguas, PR, Boston, MA & San Francisco, CA and we serve life sciences clients in six global markets: United States, Puerto Rico, Dominican Republic, Mexico, Germany, Canada, and South America. SPECIFIC DUTIES, ACTIVITIES AND RESPONSIBILITIES: Ability to assemble, install, test and maintain electrical or electronic wiring, equipment, appliances, apparatus and fixtures. Maintain electrical equipment to meet regulatory codes at state and federal levels. Demonstrate safe and proficient use of shop tools (both hand and power). Demonstrate mechanical knowledge. Competent with programming of VFD’s. Knowledge and ability to troubleshoot PLC’s. Must be physically capable of performing work from ladders, scaffolds, and roofs to install, maintain or repair electrical wiring, equipment and fixtures. Proficient in testing electrical systems and continuity of circuits in electrical wiring, equipment, and fixtures, using testing devices such as ohmmeters, voltmeters, and oscilloscopes, to ensure compatibility and safety of system. Perform duties in a work environment that will be hot, cold, dirty and fast-paced. Able to complete forms e.g. time sheets, works order request forms indicating materials used/required, times, work undertaken etc. Work overtime when required (including weekends and/or holidays). Attend emergency calls outside of normal working, if available. Perform all duties in a safe and proper manner and complying with the EHS policies. Ensure that all documents are completed complying with the GMP’s practices when required. Provide cover for other members of staff during holidays, sickness or other absences and in emergencies. Be proactive with people, keeping them informed; maintain positive relations and demonstrate good customer care. Execute preventive maintenance, troubleshooting and general repair work on specific assigned working area/site of mechanical, electrical system and equipment. Perform effectively inspections, testing and emptying secondary containment systems (dams) Correct deficiencies found in inspections. Report any spills immediately to your supervisor. Take reading of the hours of operation of boilers and fuel consumption Take reading of the hours of operation of generators and fire pumps Receive diesel for boilers and emergency generators. Ensure that boilers flow meters are calibrated in the set frequency Ensure accuracy of generators and fire pumps data taking. Monitor / document effectively routinely operational parameters to ensure optimum control and regulatory compliance. Report any deviation Provide maintenance to critical measurement equipment and tools, reporting failures and repair if necessary. Analyze fuel and water consumption to detect irregularities and take action if necessary. Ensure that leak detection system of dikes is operating properly (buoy system) Identify gaps in the utility systems and take action to repair and put into normal operation Strictly follow company’s safety and cGMP policies and procedures Able to work extra hours, at night or on weekends and irregular shifts. Able to respond to emergency calls. Maintain current electrician's license or identification card to meet governmental regulations. Electricians should have direct experience with some or all of the following activities: Cable Terminations - 600 volts to 34 KV SF6 Breakers o Installation of Electrical Equipment Open air switches to 138 KV Transformers from 1 MVA to 100 MVA High Voltage CTs and PTs HV switches to 138 KV Switchgear - 480 V, 5 KV, 15 KV Aluminum bus in HV substations480 volt MCCs Grounding systems Cathodic Protection Control Panels Installation of Control wiring and equipment Installation and repair of Insulators Pulling and terminating of conductors and pilot wires Installation of Fiber Optic cable and terminations Installation of conduit and pulling cable - large sizes and from 480 volts to 35 KV Installation of Transmission and Distribution poles Complete installation of HV Electrical Substations to 138 KV Pole Line work - 15 KV to 138 KV 37. Other duties as assigned by supervisor. EDUCATIONAL or EQUIVALENT REQUIREMENTS: Technical College Electrician Degree ​​​​​​​C-10 Contractor License awarded by the Contractor State License Board Mentor Technical Group es un empleador que ofrece igualdad de oportunidades y todos los solicitantes calificados recibirán consideración para el empleo sin importar raza, color, religión, sexo, orientación sexual, identidad de género, información genética, origen nacional, estado de veterano protegido, estado de discapacidad o cualquier otro grupo protegido por ley. Mentor Technical Group is an equal opportunity employer, and all qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, genetic information, national origin, protected veteran status, disability status, or any other characteristic protected by law.

Full job record

Job IDd112df3a7d097d3761809fd5b6907dcc17f2b1c7
Org IDe7008114-6366-44f1-801b-95c6af850168
Source IDf5fcad81-5e27-438a-9b9c-61af3019fe6d
Board IDf5fcad81-5e27-438a-9b9c-61af3019fe6d
Providerjazzhr
Provider Job KeyBJPsWJtGFV
TitleFacilities Electrician (Regulated Industry)
Normalized Title
Statusactive
Activeyes
Location TextRedwood City, CA
Department
Team
Employment Typefull_time
Workplace Type
Remote Policy
CountryUnited States
RegionCA
CityRedwood City
Salary Raw
Salary Min
Salary Max
Salary Currency
Salary Period
Source URLhttps://mentortechnicalgroup.applytojob.com/apply/BJPsWJtGFV/Facilities-Electrician-Regulated-Industry
Apply URLhttps://mentortechnicalgroup.applytojob.com/apply/BJPsWJtGFV/Facilities-Electrician-Regulated-Industry
First Seen At2026-05-30 06:10:29Z
Last Seen At2026-06-06 10:48:27Z
Last Checked At2026-06-06 10:48:27Z
Last Changed At2026-05-30 06:10:29Z
Inactive At
Source Posted At2026-05-12 00:00:00Z
Source Updated At
Raw Payload Uris3://job-postings-prod-raw-590183727216/raw/provider=jazzhr/board=mentortechnicalgroup/date=2026-06-06/2026-06-06T10-48-20-369Z-3e075af966eb7f035c58a06555bf1db0ff50abcf83d46f7b0d76d9358e94872e.json
Event Fields
{
  "content_hash": "bc59a6506b9f3c626acfcfd2c2afbc5f624a3db0729bde4c1363f22dbad11e1c",
  "source_hash": "9c2dd450a87988a022b156ae479b1c356c05731744a9ee38f47a2745604e05b0",
  "last_changed_at": "2026-05-30T06:10:29.186Z",
  "active_status": "active"
}
Parsed Structured
{
  "language": "en",
  "location": {
    "raw": "Redwood City, CA",
    "city": "Redwood City",
    "region": "CA",
    "country": "United States",
    "is_remote": false,
    "confidence": 0.9
  },
  "salary_max": null,
  "salary_min": null,
  "inferred_at": "2026-06-06T10:48:27.556Z",
  "launch_scope": {
    "reason": "jazzhr_production_catalog",
    "included": true,
    "location": {
      "raw": "Redwood City, CA",
      "city": "Redwood City",
      "region": "CA",
      "country": "United States",
      "is_remote": false,
      "confidence": 0.9
    },
    "countries": [
      "United States"
    ]
  },
  "remote_policy": null,
  "salary_period": null,
  "workplace_type": null,
  "salary_currency": null
}
Extensions
{}
Native Structured
{
  "detail": {
    "url": "https://mentortechnicalgroup.applytojob.com/apply/jobs/details/BJPsWJtGFV?&",
    "heading": "Facilities Electrician (Regulated Industry)",
    "html_title": "JazzHR » Job Listings",
    "canonical_url": "https://mentortechnicalgroup.applytojob.com/apply/BJPsWJtGFV/Facilities-Electrician-Regulated-Industry",
    "description_html": "<em>Mentor Technical Group (MTG) provides a comprehensive portfolio of technical support and solutions for the FDA-regulated industry. As a world leader in life science engineering and technical solutions, MTG has the knowledge and experience to ensure compliance with pharmaceutical, biotechnology, and medical device safety and efficacy guidelines. With offices in Caguas, PR, Boston, MA & San Francisco, CA and we serve life sciences clients in six global markets: United States, Puerto Rico, Dominican Republic, Mexico, Germany, Canada, and South America.</em><br><br><strong>SPECIFIC DUTIES, ACTIVITIES AND RESPONSIBILITIES:</strong><ol><li>Ability to assemble, install, test and maintain electrical or electronic wiring, equipment, appliances, apparatus and fixtures.</li><li>Maintain electrical equipment to meet regulatory codes at state and federal levels.</li><li>Demonstrate safe and proficient use of shop tools (both hand and power).</li><li>Demonstrate mechanical knowledge.</li><li>Competent with programming of VFD’s.</li><li>Knowledge and ability to troubleshoot PLC’s.</li><li>Must be physically capable of performing work from ladders, scaffolds, and roofs to install, maintain or repair electrical wiring, equipment and fixtures.</li><li>Proficient in testing electrical systems and continuity of circuits in electrical wiring, equipment, and fixtures, using testing devices such as ohmmeters, voltmeters, and oscilloscopes, to ensure compatibility and safety of system.</li><li>Perform duties in a work environment that will be hot, cold, dirty and fast-paced.</li><li>Able to complete forms e.g. time sheets, works order request forms indicating materials used/required, times, work undertaken etc.</li><li>Work overtime when required (including weekends and/or holidays).</li><li>Attend emergency calls outside of normal working, if available.</li><li>Perform all duties in a safe and proper manner and complying with the EHS policies.</li><li>Ensure that all documents are completed complying with the GMP’s practices when required.</li><li>Provide cover for other members of staff during holidays, sickness or other absences and in emergencies.</li><li>Be proactive with people, keeping them informed; maintain positive relations and demonstrate good customer care.</li><li>Execute preventive maintenance, troubleshooting and general repair work on specific assigned working area/site of mechanical, electrical system and equipment.</li><li>Perform effectively inspections, testing and emptying secondary containment systems (dams)</li><li>Correct deficiencies found in inspections.</li><li>Report any spills immediately to your supervisor.</li><li>Take reading of the hours of operation of boilers and fuel consumption</li><li>Take reading of the hours of operation of generators and fire pumps</li><li>Receive diesel for boilers and emergency generators.</li><li>Ensure that boilers flow meters are calibrated in the set frequency</li><li>Ensure accuracy of generators and fire pumps data taking.</li><li>Monitor / document effectively routinely operational parameters to ensure optimum control and regulatory compliance.</li><li>Report any deviation</li><li>Provide maintenance to critical measurement equipment and tools, reporting failures and repair if necessary.</li><li>Analyze fuel and water consumption to detect irregularities and take action if necessary.</li><li>Ensure that leak detection system of dikes is operating properly (buoy system)</li><li>Identify gaps in the utility systems and take action to repair and put into normal operation</li><li>Strictly follow company’s safety and cGMP policies and procedures</li><li>Able to work extra hours, at night or on weekends and irregular shifts.</li><li>Able to respond to emergency calls.</li><li>Maintain current electrician's license or identification card to meet governmental regulations.</li><li>Electricians should have direct experience with some or all of the following activities:</li></ol><ul><li>Cable Terminations - 600 volts to 34 KV</li><li>SF6 Breakers o Installation of Electrical Equipment</li><li>Open air switches to 138 KV</li><li>Transformers from 1 MVA to 100 MVA</li><li>High Voltage CTs and PTs</li><li>HV switches to 138 KV</li><li>Switchgear - 480 V, 5 KV, 15 KV</li><li>Aluminum bus in HV substations480 volt MCCs</li><li>Grounding systems</li><li>Cathodic Protection</li><li>Control Panels</li><li>Installation of Control wiring and equipment</li><li>Installation and repair of Insulators</li><li>Pulling and terminating of conductors and pilot wires</li><li>Installation of Fiber Optic cable and terminations</li><li>Installation of conduit and pulling cable - large sizes and from 480 volts to 35 KV</li><li>Installation of Transmission and Distribution poles</li><li>Complete installation of HV Electrical Substations to 138 KV</li><li>Pole Line work - 15 KV to 138 KV</li></ul><p>37. Other duties as assigned by supervisor.</p><strong>EDUCATIONAL or EQUIVALENT REQUIREMENTS:</strong><ul><li>Technical College Electrician Degree</li><li>​​​​​​​C-10 Contractor License awarded by the Contractor State License Board</li></ul><p><br />\n<strong>Mentor Technical Group es un empleador que ofrece igualdad de oportunidades y todos los solicitantes calificados recibirán consideración para el empleo sin importar raza, color, religión, sexo, orientación sexual, identidad de género, información genética, origen nacional, estado de veterano protegido, estado de discapacidad o cualquier otro grupo protegido por ley.</strong></p>\n\n<p><em><strong>Mentor Technical Group is an equal opportunity employer, and all qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, genetic information, national origin, protected veteran status, disability status, or any other characteristic protected by law.</strong></em></p>",
    "description_text": "Mentor Technical Group (MTG) provides a comprehensive portfolio of technical support and solutions for the FDA-regulated industry. As a world leader in life science engineering and technical solutions, MTG has the knowledge and experience to ensure compliance with pharmaceutical, biotechnology, and medical device safety and efficacy guidelines. With offices in Caguas, PR, Boston, MA & San Francisco, CA and we serve life sciences clients in six global markets: United States, Puerto Rico, Dominican Republic, Mexico, Germany, Canada, and South America.\n SPECIFIC DUTIES, ACTIVITIES AND RESPONSIBILITIES: Ability to assemble, install, test and maintain electrical or electronic wiring, equipment, appliances, apparatus and fixtures.\n Maintain electrical equipment to meet regulatory codes at state and federal levels.\n Demonstrate safe and proficient use of shop tools (both hand and power).\n Demonstrate mechanical knowledge.\n Competent with programming of VFD’s.\n Knowledge and ability to troubleshoot PLC’s.\n Must be physically capable of performing work from ladders, scaffolds, and roofs to install, maintain or repair electrical wiring, equipment and fixtures.\n Proficient in testing electrical systems and continuity of circuits in electrical wiring, equipment, and fixtures, using testing devices such as ohmmeters, voltmeters, and oscilloscopes, to ensure compatibility and safety of system.\n Perform duties in a work environment that will be hot, cold, dirty and fast-paced.\n Able to complete forms e.g. time sheets, works order request forms indicating materials used/required, times, work undertaken etc.\n Work overtime when required (including weekends and/or holidays).\n Attend emergency calls outside of normal working, if available.\n Perform all duties in a safe and proper manner and complying with the EHS policies.\n Ensure that all documents are completed complying with the GMP’s practices when required.\n Provide cover for other members of staff during holidays, sickness or other absences and in emergencies.\n Be proactive with people, keeping them informed; maintain positive relations and demonstrate good customer care.\n Execute preventive maintenance, troubleshooting and general repair work on specific assigned working area/site of mechanical, electrical system and equipment.\n Perform effectively inspections, testing and emptying secondary containment systems (dams)\n Correct deficiencies found in inspections.\n Report any spills immediately to your supervisor.\n Take reading of the hours of operation of boilers and fuel consumption\n Take reading of the hours of operation of generators and fire pumps\n Receive diesel for boilers and emergency generators.\n Ensure that boilers flow meters are calibrated in the set frequency\n Ensure accuracy of generators and fire pumps data taking.\n Monitor / document effectively routinely operational parameters to ensure optimum control and regulatory compliance.\n Report any deviation\n Provide maintenance to critical measurement equipment and tools, reporting failures and repair if necessary.\n Analyze fuel and water consumption to detect irregularities and take action if necessary.\n Ensure that leak detection system of dikes is operating properly (buoy system)\n Identify gaps in the utility systems and take action to repair and put into normal operation\n Strictly follow company’s safety and cGMP policies and procedures\n Able to work extra hours, at night or on weekends and irregular shifts.\n Able to respond to emergency calls.\n Maintain current electrician's license or identification card to meet governmental regulations.\n Electricians should have direct experience with some or all of the following activities:\n Cable Terminations - 600 volts to 34 KV\n SF6 Breakers o Installation of Electrical Equipment\n Open air switches to 138 KV\n Transformers from 1 MVA to 100 MVA\n High Voltage CTs and PTs\n HV switches to 138 KV\n Switchgear - 480 V, 5 KV, 15 KV\n Aluminum bus in HV substations480 volt MCCs\n Grounding systems\n Cathodic Protection\n Control Panels\n Installation of Control wiring and equipment\n Installation and repair of Insulators\n Pulling and terminating of conductors and pilot wires\n Installation of Fiber Optic cable and terminations\n Installation of conduit and pulling cable - large sizes and from 480 volts to 35 KV\n Installation of Transmission and Distribution poles\n Complete installation of HV Electrical Substations to 138 KV\n Pole Line work - 15 KV to 138 KV\n 37. Other duties as assigned by supervisor.\n EDUCATIONAL or EQUIVALENT REQUIREMENTS: Technical College Electrician Degree\n ​​​​​​​C-10 Contractor License awarded by the Contractor State License Board\n Mentor Technical Group es un empleador que ofrece igualdad de oportunidades y todos los solicitantes calificados recibirán consideración para el empleo sin importar raza, color, religión, sexo, orientación sexual, identidad de género, información genética, origen nacional, estado de veterano protegido, estado de discapacidad o cualquier otro grupo protegido por ley.\n Mentor Technical Group is an equal opportunity employer, and all qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, genetic information, national origin, protected veteran status, disability status, or any other characteristic protected by law.",
    "jsonld_jobposting": {
      "url": "https://mentortechnicalgroup.applytojob.com/apply/BJPsWJtGFV/Facilities-Electrician-Regulated-Industry",
      "@type": "JobPosting",
      "title": "Facilities Electrician (Regulated Industry)",
      "@context": "http://schema.org/",
      "datePosted": "2026-05-12",
      "description": "<em>Mentor Technical Group (MTG) provides a comprehensive portfolio of technical support and solutions for the FDA-regulated industry. As a world leader in life science engineering and technical solutions, MTG has the knowledge and experience to ensure compliance with pharmaceutical, biotechnology, and medical device safety and efficacy guidelines. With offices in Caguas, PR, Boston, MA & San Francisco, CA and we serve life sciences clients in six global markets: United States, Puerto Rico, Dominican Republic, Mexico, Germany, Canada, and South America.</em><br><br><strong>SPECIFIC DUTIES, ACTIVITIES AND RESPONSIBILITIES:</strong><ol><li>Ability to assemble, install, test and maintain electrical or electronic wiring, equipment, appliances, apparatus and fixtures.</li><li>Maintain electrical equipment to meet regulatory codes at state and federal levels.</li><li>Demonstrate safe and proficient use of shop tools (both hand and power).</li><li>Demonstrate mechanical knowledge.</li><li>Competent with programming of VFD’s.</li><li>Knowledge and ability to troubleshoot PLC’s.</li><li>Must be physically capable of performing work from ladders, scaffolds, and roofs to install, maintain or repair electrical wiring, equipment and fixtures.</li><li>Proficient in testing electrical systems and continuity of circuits in electrical wiring, equipment, and fixtures, using testing devices such as ohmmeters, voltmeters, and oscilloscopes, to ensure compatibility and safety of system.</li><li>Perform duties in a work environment that will be hot, cold, dirty and fast-paced.</li><li>Able to complete forms e.g. time sheets, works order request forms indicating materials used/required, times, work undertaken etc.</li><li>Work overtime when required (including weekends and/or holidays).</li><li>Attend emergency calls outside of normal working, if available.</li><li>Perform all duties in a safe and proper manner and complying with the EHS policies.</li><li>Ensure that all documents are completed complying with the GMP’s practices when required.</li><li>Provide cover for other members of staff during holidays, sickness or other absences and in emergencies.</li><li>Be proactive with people, keeping them informed; maintain positive relations and demonstrate good customer care.</li><li>Execute preventive maintenance, troubleshooting and general repair work on specific assigned working area/site of mechanical, electrical system and equipment.</li><li>Perform effectively inspections, testing and emptying secondary containment systems (dams)</li><li>Correct deficiencies found in inspections.</li><li>Report any spills immediately to your supervisor.</li><li>Take reading of the hours of operation of boilers and fuel consumption</li><li>Take reading of the hours of operation of generators and fire pumps</li><li>Receive diesel for boilers and emergency generators.</li><li>Ensure that boilers flow meters are calibrated in the set frequency</li><li>Ensure accuracy of generators and fire pumps data taking.</li><li>Monitor / document effectively routinely operational parameters to ensure optimum control and regulatory compliance.</li><li>Report any deviation</li><li>Provide maintenance to critical measurement equipment and tools, reporting failures and repair if necessary.</li><li>Analyze fuel and water consumption to detect irregularities and take action if necessary.</li><li>Ensure that leak detection system of dikes is operating properly (buoy system)</li><li>Identify gaps in the utility systems and take action to repair and put into normal operation</li><li>Strictly follow company’s safety and cGMP policies and procedures</li><li>Able to work extra hours, at night or on weekends and irregular shifts.</li><li>Able to respond to emergency calls.</li><li>Maintain current electrician's license or identification card to meet governmental regulations.</li><li>Electricians should have direct experience with some or all of the following activities:</li></ol><ul><li>Cable Terminations - 600 volts to 34 KV</li><li>SF6 Breakers o Installation of Electrical Equipment</li><li>Open air switches to 138 KV</li><li>Transformers from 1 MVA to 100 MVA</li><li>High Voltage CTs and PTs</li><li>HV switches to 138 KV</li><li>Switchgear - 480 V, 5 KV, 15 KV</li><li>Aluminum bus in HV substations480 volt MCCs</li><li>Grounding systems</li><li>Cathodic Protection</li><li>Control Panels</li><li>Installation of Control wiring and equipment</li><li>Installation and repair of Insulators</li><li>Pulling and terminating of conductors and pilot wires</li><li>Installation of Fiber Optic cable and terminations</li><li>Installation of conduit and pulling cable - large sizes and from 480 volts to 35 KV</li><li>Installation of Transmission and Distribution poles</li><li>Complete installation of HV Electrical Substations to 138 KV</li><li>Pole Line work - 15 KV to 138 KV</li></ul><p>37. Other duties as assigned by supervisor.</p><strong>EDUCATIONAL or EQUIVALENT REQUIREMENTS:</strong><ul><li>Technical College Electrician Degree</li><li>​​​​​​​C-10 Contractor License awarded by the Contractor State License Board</li></ul><p><br />\n<strong>Mentor Technical Group es un empleador que ofrece igualdad de oportunidades y todos los solicitantes calificados recibirán consideración para el empleo sin importar raza, color, religión, sexo, orientación sexual, identidad de género, información genética, origen nacional, estado de veterano protegido, estado de discapacidad o cualquier otro grupo protegido por ley.</strong></p>\n\n<p><em><strong>Mentor Technical Group is an equal opportunity employer, and all qualified applicants will receive consideration for employment without regard to race, color, religion, sex, sexual orientation, gender identity, genetic information, national origin, protected veteran status, disability status, or any other characteristic protected by law.</strong></em></p>",
      "jobLocation": {
        "@type": "Place",
        "address": {
          "@type": "PostalAddress",
          "postalCode": "",
          "addressRegion": "CA",
          "addressLocality": "Redwood City"
        }
      },
      "validThrough": "2026-08-10",
      "uniqueJobCode": "job_20260512160438_JPLBEJ8CDG5GC2Z6",
      "employmentType": "FULL_TIME",
      "hiringOrganization": {
        "logo": "https://s3.amazonaws.com/resumator/customer_20130920185631_PQKEJQULIUBHBKST/logos/20240223213458_Mentor_Tech_Logo_-_Transparent_Background_JazzHR.png",
        "name": "Mentor Technical Group",
        "@type": "Organization",
        "sameAs": "http://www.mentortg.com"
      },
      "experienceRequirements": "Experienced"
    }
  },
  "list_job": {
    "id": "BJPsWJtGFV",
    "title": "Facilities Electrician (Regulated Industry)",
    "detailUrl": "https://mentortechnicalgroup.applytojob.com/apply/jobs/details/BJPsWJtGFV?&"
  },
  "detail_errors": []
}
Get this page with API

Rendered from the bluedoor Job Postings API. Reproduce it:

GET https://api.bluedoor.sh/job-postings/v1/jobs/d112df3a7d097d3761809fd5b6907dcc17f2b1c7?include=descriptionJSON
GET https://api.bluedoor.sh/job-postings/v1/orgs/e7008114-6366-44f1-801b-95c6af850168JSON
GET https://api.bluedoor.sh/job-postings/v1/sources/f5fcad81-5e27-438a-9b9c-61af3019fe6dJSON
GET https://api.bluedoor.sh/job-postings/v1/jobs/d112df3a7d097d3761809fd5b6907dcc17f2b1c7/eventsJSON